background image

 
 

 

28

aTCA-9710 

Threshold 

Sensor 

Type 

LNR 

LC 

LNC 

UNC 

UC 

UNR 

5.00V 

SYS 

Volts  5.502 5.408 5.314 4.703 4.609 4.515 

12.0V 

SYS 

Volts  13.24  13  12.76 11.32 11.08 10.84 

1.05V 

VCCIO 

Volts  1.216 1.168 1.104 0.992 0.96 0.896 

1.80V 

VCCIN_CPU0 

Volts 1.856 

1.84 

1.824 1.6 1.536 

1.456 

1.80V 

VCCIN_CPU1 

Volts 1.856 

1.84 

1.824 1.6 1.536 

1.456 

1.20V 

VDDQ_AB 

Volts  1.392 1.344 1.312 1.104 1.056 1.024 

1.20V 

VDDQ_CD 

Volts  1.392 1.344 1.312 1.104 1.056 1.024 

1.20V 

VDDQ_EF 

Volts  1.392 1.344 1.312 1.104 1.056 1.024 

1.20V 

VDDQ_GH 

Volts  1.392 1.344 1.312 1.104 1.056 1.024 

0.60V 

VTT_AB 

Volts 

0.72  0.688  0.64  0.576 0.528 0.496 

0.60V 

VTT_CD 

Volts 

0.72  0.688  0.64  0.576 0.528 0.496 

0.60V 

VTT_EF 

Volts 

0.72  0.688  0.64  0.576 0.528 0.496 

0.60V 

VTT_GH 

Volts 

0.72  0.688  0.64  0.576 0.528 0.496 

CPU1 Temp 

°C 

107 

97 

87 

-5 

-10 

-15 

CPU2 Temp 

°C 

107 

97 

87 

-5 

-10 

-15 

PCH Temp 

°C 

95 

85 

75 

-5 

-10 

DC/DC Temp 

°C 

95 

85 

75 

-5 

-10 

XL710 Temp 

°C 

95 

85 

75 

-5 

-10 

CPU1 VRM1 Temp 

°C 95 

85 

75 

0 -5 

-10 

CPU1 VRM2 Temp 

°C 95 

85 

75 

0 -5 

-10 

CPU1 VRM3 Temp 

°C 95 

85 

75 

0 -5 

-10 

CPU2 VRM1 Temp 

°C 95 

85 

75 

0 -5 

-10 

CPU2 VRM2 Temp 

°C 95 

85 

75 

0 -5 

-10 

CPU2 VRM3 Temp 

°C 95 

85 

75 

0 -5 

-10 

 
 

Summary of Contents for aTCA-9710

Page 1: ...Leading EDGE COMPUTING aTCA 9710 Dual Intel Xeon E5 2658 v3 40G AdvancedTCA Processor Blade User s Manual Manual Revision 1 0 Revision Date June 6 2018 Part No 50 1G040 1000 ...

Page 2: ...tion of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enforced measures to ensure that our products manufacturing processes components and raw materials have as little impact on the environment as possible When products are at their end of life our customers are encouraged to dispose of...

Page 3: ...mes mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their respective companies Revision History Revision Release Date Description of Change s 1 0 6 6 2018 Initial release ...

Page 4: ... 1 4 Silicon Motion SM750 Graphics Controller 21 3 2 Peripherals 21 3 2 1 Reset 21 3 2 2 SMBus Devices 22 3 3 I O Interfaces 23 3 3 1 USB 23 3 3 2 VGA Interface 24 3 3 3 Ethernet Connection 24 3 3 4 Serial Port 25 3 3 5 Onboard mSATA Module 25 3 3 6 Switch And Jumper Settings 25 4 Intelligent Platform Management System 27 4 1 IPMI Sensors 27 4 1 1 Sensor Reading FRU Hotswap Sensor 29 4 1 2 Get Sen...

Page 5: ...4 1 Processor Configuration 67 6 4 2 Advanced Power Management Configuration 69 6 4 3 Common RefCode Configuration 71 6 4 4 Memory Configuration 71 6 4 5 IIO Configuration 73 6 4 6 PCH Configuration 74 6 5 Server Mgmt Setup Screen 75 6 6 Boot Setup Screen 76 6 7 Security Setup Screen 77 6 8 Save Exit Setup Screen 78 7 Serial Over LAN 80 7 1 Preparation For SOL Connection 80 7 2 Configure The Remot...

Page 6: ...esign only The robust computing power and reliability of the aTCA 9710 meets the requirements of telecom equipment manufacturers TEMs and network equipment providers NEPs allowing them to build the next generation telecom networks and communication infrastructures Detailed features are outlined below and a functional block diagram is shown in the next section Two 12 core Intel Xeon processor E5 26...

Page 7: ...7 aTCA 9710 1 2 Block Diagram ...

Page 8: ... shipping carton and packing material for inspection by the dealer Obtain authorization before returning any product to ADLINK Check that the following items are included in the package If there are any missing items contact your dealer aTCA 9710 AdvancedTCA processor blade CPU RAM specifications may differ depending on options selected USB Mini B to DB 9 cable for front panel serial port ...

Page 9: ...nnels via two XL 710 AM2 40G Ethernet Controllers Option 9 KR 6x 10GBASE SFP ports on RTM aTCA R9700 Display Silicon Motion SM750 graphics controller Front panel analog VGA connector supports up to 1920x1440 resolution USB 2x USB 2 0 ports on front panel two USB 2 0 ports to RTM Serial 1x IPMC serial debug port USB Mini B 1x RS 232 ports on front panel USB Mini B 1x RS 232 port to RTM Storage Onbo...

Page 10: ...ronmental Dimensions 322 25mm x 280mm x 30 48mm H x D x W 6HP slot Operating Temperature Standard 0 C to 55 C NEBS short term 0 C to 61 C sea level Storage Temperature 40 C to 85 C Humidity 5 to 90 non condensing Shock 15G peak to peak 11ms duration non operation Vibration Non operating 1 88 Grms 5 to 500 Hz each axis Operating 0 5 Grms 5 to 500Hz each axis Compliance CE FCC Class A UL NEBS Level ...

Page 11: ... Supply Chroma DC Power supply 62012P 80 60 4 CPU 2x 12 core Intel Xeon processor E5 2658 v3 The following table lists power consumption under different operating systems and applications with a 48V power rail OS and Application Power Consumption Windows Server 2008 R2 idle 81 12 W Windows Server 2008 R2 BurnIn Test CPU 100 usage 316 32 W Windows Server 2008 R2 Power Thermal Utility CPU 100 Usage ...

Page 12: ...S CN7 Ground connection SW3 IPMC Programming mode DIMM_AB CD DDR4 DIMM A D SW4 IPMC Mode Select DIMM_EF GH DDR4 DIMM E H SW6 HW Reset Button J3 4 Zone 3 to RTM SW7 Reserved for XL710 debug PSU1 400W 48V DC DC module SW8 Reserved for XL710 debug PSU2 400W Hot Swap Power Module CPU1 CPU2 J3 SW4 SW1 CN7 DIMM_GH CN2 J4 SW8 PSU1 CN1 DIMM_CD SW7 DIMM_EF DIMM_AB PSU2 B1 A1 SW3 C1 D1 B2 A2 C2 D2 H1 G1 E1 ...

Page 13: ...13 aTCA 9710 2 3 2 aTCA 9710 Board Layout Solder Side Location Description SW2 Clear CMOS SW6 HW Reset Button SW6 SW2 ...

Page 14: ...aTCA 9710 Front Panel VGA 10GbE SFP USB IPMC Serial Debug Port RS 232 Serial Port Base and Fabric Channel LEDs Reset button OOS LED BIOS OS Boot OK IPMC Payload Power Authorized IPMC Chassis Identify Command Hot Swap LED ...

Page 15: ...d LED 2 3 4 1 Out of Service OOS LED Out of Service LED Red State Remark Blinking During BIOS POST M4 Off BIOS POST OK M4 On After OS shutdown M1 2 3 4 2 BIOS OS Boot OK BIOS OS Boot OK Green State Remark Blinking During OS Boot Off During BIOS POST On OS Boot OK 2 3 4 3 IPMC Payload Power Authorized IPMC Payload Power Authorized Amber State Remark On Payload Power Authorized Off Payload Power Not...

Page 16: ...inking Chassis Identify Command Active 2 3 4 5 Hot swap LED Hot swap LED Blue FRU State number FRU State Name Off M0 FRU not installed On M1 FRU inactive Long blink M2 FRU activation request Off M3 FRU activation in process Off M4 FRU active Short blink M5 FRU deactivation request Short blink M6 FRU deactivation in process ...

Page 17: ... accessing Ethernet I O Fabric 3 Link Amber 40Gbps ON FCH 4 ACT Amber Blink when accessing Ethernet I O Fabric 4 Link Amber 40Gbps ON BCH1 ACT Amber Blink when accessing Ethernet I O BCH1 Speed and Link 100 Mbps Green 1Gbps Amber BCH2 ACT Amber Blink when accessing Ethernet I O BCH2 Speed and Link 100 Mbps Green 1Gbps Amber 2 3 4 7 Front Panel 10GbE SFP LEDs Left LED Speed and Link 1Gbps Amber 100...

Page 18: ...18 aTCA 9710 2 4 Compliance The aTCA 9710 conforms to the following specifications PICMG 3 0 R2 0 ECN0002 AdvancedTCA PICMG 3 1 Ethernet over AdvancedTCA Option 9 KR NEBS Level 3 design ...

Page 19: ... Intel SpeedStep Technology Intel Virtualization Technology Intel VT Intel Hyper Threading Technology Intel HT Technology The Intel Xeon processor E5 2658 v3 has a maximum TDP of 105W and has an elevated case temperature specification The elevated case temperatures are intended to meet the short term thermal profile requirements of NEBS Level 3 The Intel Xeon processor E5 2658 v3 is ideal for ther...

Page 20: ...rocessors Functions and capabilities include PCI Express Base Specification Revision 2 0 support for up to eight ports with transfers up to 5 GT s ACPI Power Management Logic Support Revision 4 0a Enhanced DMA controller interrupt controller and timer functions Integrated Serial ATA host controller switch independent DMA operation on up to 10 ports USB host interface with two EHCI high speed USB 2...

Page 21: ...pecifications UV 16 32 bit RGB conversion ReduceOn Power Management Technology Quick Rotation features allow for 90 180 and 270 rotation of on screen images 3 2 Peripherals The following peripherals are available on the aTCA 9710 blade 3 2 1 Reset The aTCA 9710 is automatically reset by a precision voltage monitoring circuit that detects a drop in voltage below the acceptable operating limit of 4 ...

Page 22: ...2 DIMM G2 DIMM H2 CPU DDR I2C Bus EEPROM FRU 24C256 SMBus I O PCA9555 LM73 x3 Thermal Sensor SMBUS ADDRESS 0x90 92 94 SMBUS ADDRESS 0x5A HW Monitor NCT7904D SMBUS ADDRESS S U B M S 0 4 x 0 ADDRESS 0xA6 I2CCLK_IPM SMBUS ADDRESS 0xE0 I2C SWITCH PCA9545A Thermal Sensor LM73 x3 Thermal Sensor LM73 x3 SMBus I O PCA9555 SMBUS ADDRESS 0x42 SMBUS ADDRESS 0x5E HOT SWAP IQ65033 PIM400KZ SMBUS ADDRESS 0xD0 D...

Page 23: ...ed full speed and low speed capable Hi speed USB 2 0 allows data transfers of up to 480 Mb s 40 times faster than a full speed USB USB 1 1 One USB peripheral may be connected to each port With the aTCA R6280 RTM the aTCA 9710 supports two additional USB ports on the I O panel of the RTM USB Connector Pin Definition Type A Pin Signal 1 5V USB VCC 2 USB 3 USB 4 GND USB Note The aTCA 9710 host interf...

Page 24: ...e 2 Base Channels 1 and 2 BCH1 BCH2 Two Intel XL 710 AM2 40G network controllers are installed on the aTCA 9710 providing four 40GBASE KR4 links to Fabric Channels 1 2 3 and 4 The four 40GBASE KR4 links are divided into two groups FCH1 3 are connected to one of the XL 710 AM2 40G network controllers while FCH2 4 are connected to the other Note The bandwidth of each XL 710 40G network controller is...

Page 25: ...s a SATA 6 0Gb s interface with sustained read to 550MB per second and sustained write up to 500MB per second 3 3 6 Switch And Jumper Settings 3 3 6 1 Set Blade Operation Mode Use switch SW4 to set the Blade Operation Mode Normal operation requires a shelf manager for the blade to boot Standalone mode allows the blade to boot without a shelf manager SW4 Blade Operation Pin 1 Pin 2 Pin 3 Pin 4 Norm...

Page 26: ...TCA 9710 3 3 6 3 Shelf Logic Ground Jumper Use CN7 to short Shelf Ground to Logic Ground Shelf Logic GND CN7 Setting Shorted 1 2 Open default 2 3 The locations of SW3 SW4 and CN7 are shown below SW4 CN7 SW3 ...

Page 27: ...sors The following table lists all the sensors supported by the aTCA 9710 Six thresholds including Lower Non Recoverable LNR Lower Critical LC Lower Non Critical LNC Upper Non Critical UNC Upper Critical UC and Upper Non Critical UNR are defined for each voltage or temperature sensor Threshold Sensor Type LNR LC LNC UNC UC UNR Hot Swap Discrete N A N A N A N A N A N A IPMB Physical Discrete N A N ...

Page 28: ...olts 1 392 1 344 1 312 1 104 1 056 1 024 1 20V VDDQ_GH Volts 1 392 1 344 1 312 1 104 1 056 1 024 0 60V VTT_AB Volts 0 72 0 688 0 64 0 576 0 528 0 496 0 60V VTT_CD Volts 0 72 0 688 0 64 0 576 0 528 0 496 0 60V VTT_EF Volts 0 72 0 688 0 64 0 576 0 528 0 496 0 60V VTT_GH Volts 0 72 0 688 0 64 0 576 0 528 0 496 CPU1 Temp C 107 97 87 5 10 15 CPU2 Temp C 107 97 87 5 10 15 PCH Temp C 95 85 75 0 5 10 DC D...

Page 29: ...ired if it is possible for the IPM Controller to receive and process a Get Sensor Reading or Get Sensor Event Status command for the sensor before the update has completed This is most likely to be the case for sensors such as fan RPM sensors that may require seconds to accumulate the first reading after a re arm 4 0 reserved Ignore on read 4 Current State Mask 7 1b FRU Operational State M7 Commun...

Page 30: ...f it is causing a bus hang 7h Undiagnosed Communications Failure 3 Standard IPMI byte see Get Sensor Reading in IPMI specification 7 0b All Event Messages disabled from this sensor 6 0b Sensor scanning disabled 5 1b Initial update in progress This bit is set to indicate that a Re arm Sensor Events or Set Event Receiver command has been used to request an update of the sensor status and that update...

Page 31: ...us only no action no interrupt Hard Reset Power Down Power Cycle reserved Timer interrupt The Event Data 2 field for this command can be used to provide an event extension code with the following definition 7 4 interrupt type 0h none 1h SMI 2h NMI 3h Messaging Interrupt Fh unspecified all other reserved 3 0 timer use at expiration 0h reserved 1h BIOS FRB2 2h BIOS POST 3h OS Load 4h SMS OS 5h OEM F...

Page 32: ...ange with the following definition Event Data 2 7 0 Version change type 00h unspecified 01h management controller device ID change in one or more fields from Get Device ID 02h management controller firmware revision 03h management controller device revision 04h management controller manufacturer ID 05h management controller IPMI version 06h management controller auxiliary firmware ID 07h managemen...

Page 33: ...h Firmware BIOS ROM corruption detected 0Ch CPU voltage mismatch processors that share same supply have mismatched voltage requirements 0Dh CPU speed matching failure 0Eh to FFh reserved System Firmware Hang uses same Event Data 2 definition as following System Firmware Progress offset System Firmware Progress The Event Data 2 field can be used to provide an event extension code with the following...

Page 34: ...he controller to receive and process a Get Sensor Reading or Get Sensor Event Status command for the sensor before the update has completed This is most likely to be the case for sensors such as fan RPM sensors that may require seconds to accumulate the first reading after a re arm The bit is also used to indicate when a reading state is unavailable because the management controller cannot obtain ...

Page 35: ...b state 0 asserted 5 For discrete reading sensors only Optional 00h Otherwise 7 reserved Returned as 1b Ignore on read 6 1b state 14 asserted 5 1b state 13 asserted 4 1b state 12 asserted 3 1b state 11 asserted 2 1b state 10 asserted 1 1b state 9 asserted 0 1b state 8 asserted ...

Page 36: ...bal Enables Get BMC Global Enables Clear Message Flags Get Message Flags Get Message Send Message Master Write Read BMC Watchdog Timer Reset Watchdog Timer Set Watchdog Timer Get Watchdog Timer Chassis Device Commands Chassis Identify Set System Boot Option Get System Boot Option Event Commands Set Event Receiver Get Event Receiver Platform Event Sensor Device Commands Get Device SDR Info Get Devi...

Page 37: ...sults Query Rollback status Initiate Manual Rollback AdvancedTCA Get PICMG Properties Get Address Info FRU Control FRU Control Capabilities Get FRU LED Properties Get LED Color Capabilities Set FRU LED State Get FRU LED State Set IPMB State Set FRU Activation Policy Get FRU Activation Policy Set FRU Activation Get Device Locator Record ID Get Port State Set Port State Compute Power Properties Set ...

Page 38: ...o comply with these requirements Exercised due care when handling the board as the heat sink can get very hot Do not touch the heat sink when installing or removing the board The board should not be placed on any surface or in any form of storage container until the board and heat sink have cooled down to room temperature This ATCA blade contains electrostatic sensitive devices Please observe the ...

Page 39: ...talling and Removing the aTCA 9710 5 2 1 Installing the Blade Follow these steps to install the aTCA 9710 blade to the chassis Step 1 Carefully align the board edges with the chassis guide rails and push the blade inwards ...

Page 40: ...s at both ends of the module are correctly inserted into the proper openings Push inwards on the handles until the blade is firmly seated in the chassis Do not force the handles if there is any abnormal resistance or it could damage the connectors and or backplane ...

Page 41: ...41 aTCA 9710 Step 3 Push the ejector handles inwards until it is locked ...

Page 42: ...42 aTCA 9710 Step 4 Lock both ends of the captive screws ...

Page 43: ...43 aTCA 9710 5 2 2 Removing the Blade Follow these steps to remove the aTCA 9710 blade from the chassis Step 1 Unlock both ends of the captive screws ...

Page 44: ...44 aTCA 9710 Step 2 Pinch the lever and latch together then pull outwards to release the ejector handles at both ends Lever Latch ...

Page 45: ...45 aTCA 9710 Step 3 Pull the blade outwards from the chassis until it is removed ...

Page 46: ...te This parameter specifies the serial device and baud rate settings to use For Linux hosts the serial device is the system path to the device node e g dev ttyS0 Perform the following steps to update the IPMC firmware Step 1 Prepare an external host PC with Linux OS and connect it to the serial port on the aTCA 9710 via the COM port USB Mini B on the front panel Put the IPMItool utility and new fi...

Page 47: ...the IPMItool utility can be used Step2 Put IPMItool and target image in the Linux system then enter the following command Step3 Select y and wait until the string of firmware update procedure successful is displayed To update other images BIOS FRU etc just replace the target image and the file name while typing command Item File name IPMC firmware hpm1fw img BIOS hpm1bios img ...

Page 48: ...address of the IPMC Please follow the step to update firmware Step1 Prepare an external x86 PC and connect the target aTCA 9710 via BASE Interface Put IPMItool and target image on the x86 PC with Linux system Enter the following command Step2 Select y and wait until the string of firmware update procedure successful is displayed To update other images BIOS FRU etc just replace the target image and...

Page 49: ...OS Setup Screen To enter the setup screen follow these steps Step 1 Power on the aTCA 9710 Step 2 Press the DEL key on a USB keyboard when you see the following text prompt on boot up screen Step 3 After you press the DEL key the Main BIOS setup menu will be displayed You can access the other setup screen from the BIOS setup utility such as CPU configuration USB configuration and so on ...

Page 50: ...o select a setup item or sub screen Plus Minus the Plus and Minus Arrow keys allow you to change the field value of a particular setup item For example Date and Time ESC The Esc key allows you to discard any changes you have made and exit the Setup Press the Esc key to exit the setup without saving your changes Press the Enter key to discard changes and exit You can also use the Arrow key to selec...

Page 51: ...tion only The upper right part of the screen displays the description of the selected option The lower right part of the screen shows the navigation keys that user can use The Main setup screen is shown below System Language Choose the language of BIOS setup utility So far there is only English is supported on aTCA 9710 System Time System Date Use these two options to change system time and date H...

Page 52: ...c is the BIOS vendor that aTCA 9710 is using Core Version Shows what core version is used from AMI to develop aTCA 9710 s BIOS Compliancy Shows what version of EFI specification is compliant with aTCA 9710 s BIOS BIOS Revision Shows revision of aTCA 9710 s BIOS Build Date and Time Shows date and time that aTCA 9710 BIOS is released Total Memory Shows the memory size on aTCA 9710 ...

Page 53: ...IOS sub menu or option by highlighting it using the Arrow keys The Advanced BIOS setup screen is shown below The sub menus are described in the following sections Front 10G LAN1 2 PXE ROM Enable or Disable PXE ROM OF FRONT 10G LAN Set this value to Enabled Disabled BASE 1G LAN1 2 PXE ROM Enable or Disable PXE ROM OF BASE 1G LAN Set this value to Enabled Disabled Fabric 40G LAN1 2 PXE ROM Enable or...

Page 54: ...PXE ROM OF RTM 10G LAN1 2 Set this value to Enabled Disabled RTM 10G LAN3 4 PXE ROM Enable or Disable PXE ROM OF RTM 10G LAN3 4 Set this value to Enabled Disabled RTM 10G LAN5 6 PXE ROM Enable or Disable PXE ROM OF RTM 10G LAN5 6 Set this value to Enabled Disabled Coleto Creek Control Enable or Disable Coleto Creek plug in card Set this value to Enabled Disabled ...

Page 55: ...the right side of the screen The settings are described on this page The screen is shown below Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Set this value to Enabled Disabled Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep State This option may be not effective with some OS Set this value to Enabled Disabled Lock Legacy Resources En...

Page 56: ... Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on this page The screen is shown below Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA The screen is shown below Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB The screen is shown below ...

Page 57: ...57 aTCA 9710 Serial PortGSIO200 Enable or Disable Serial Port COM Set this value to Enabled Disabled ...

Page 58: ...ys to select an item Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on the following pages An example of the Serial Port Console Redirection screen is shown below Console Redirection The BIOS Console Redirection feature here Set this value to Enable Disable ...

Page 59: ...ferred terminal type for out of band management Configuration options VT100 VT100 VT UTF8 ANSI Bits per second Select the bits per second you want the serial port to use for console redirection The options are 115200 57600 38400 19200 9600 Data Bits Select the data bits you want the serial port to use for console redirection Set this value to 7 8 Parity Set this option to select Parity for console...

Page 60: ...Enabled this mode only text will be sent This is to capture terminal data Set this value to Enable Disable Resolution 100x31 Set this option to extended terminal resolution Set this value to Enable Disable Legacy OS Redirection On Legacy OS the number of rows and columns supported redirection Set this value to 80x24 80x25 Putty KeyPad Select function key and keypad on putty Set this value to VT100...

Page 61: ...m Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on this page The screen is shown below SR IOV Support If system has SR IOV capable PCIe Devices this option Enables or Disables Single Root IO Virtualization Support Set this value to Enabled Disabled ...

Page 62: ...een is shown below Network Stack Enable Disable UEFI Network Stack Set this value to Enabled Disabled IPv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Set this value to Enabled Disabled IPv6 PXE Support Enable Ipv6 PXE Boot Support If disabled IPV6 PXE boot option will not be created Set this value to Enabled Disabled PXE boot wait time Wait time t...

Page 63: ...en The settings are described on this page The screen is shown below CSM Support Enable Disable CSM Support Set this value to Enabled Disabled Boot option filter This option controls whether to hide Legacy UEFI boot options Set this value to UEFI and Legacy Legacy only UEFI only Network Controls the execution of UEFI and Legacy PXE OpROM Set this value to Do not launch UEFI Legacy Storage Controls...

Page 64: ...pport Security Device Support Enable for BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will be available TPM State Enable Disable Security Device Note Your computer will reboot during restart in order to change State of the device Pending operation Schedule an Operation for the Security Device NOTE your computer will reboot during restart i...

Page 65: ...g Timer Expiration value Set this value to 3 minutes 4 minutes 5 minutes 6 minutes POST Watchdog Timer Policy Configure how the system should respond if the POST Watchdog Timer expires Not available if POST Watchdog Timer is disabled Set this value to Reset Power Down Do Nothing OS Load Watchdog Timer Enable or Disable OS Watchdog Timer Set this value to Enabled Disabled OS Load Watchdog Timeout S...

Page 66: ... to enter the Intel RC Setup screen You can select any of the items in the left frame of the screen such as Processor Configuration to go to the sub menu for that item You can display an IntelRCSetup option by highlighting it using the Arrow keys The IntelRCSetup screen is shown below ...

Page 67: ... side of the screen The settings are described on this page The screen is shown below Hyper Threading ALL Enables Hyper Threading Software Method to Enable Disable Logical Processor threads Set this value to Enabled Disabled Enable Intel TXT Support Enables Intel Trusted Execution Technology Configuration Please disable EV DFX Features when TXT is enabled Set this value to Enabled Disabled VMX Ena...

Page 68: ...68 aTCA 9710 Per Socket Configuration Change Per Socket settings The screen is shown below Cores Enabled Number of Cores to Enable 0 means all cores ...

Page 69: ...an item Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on this page The screen is shown below Power Technology Enable the power management features Set this value to Disable Energy Efficient Custom Config TDP Option to disable enable Config TDP Set this value to Enable Disable ...

Page 70: ...hen disabled CPU frequency is set at max non turbo Set this value to Enable Disable Turbo Mode Enable or Disable CPU Turbo mode Set this value to Enable Disable CPU T State Control The screen is shown below ACPI T States Enable Disable CPU throttling by OS Throttling reduces power consumption Set this value to Enable Disable ...

Page 71: ...creen The settings are described on this page The screen is shown below Numa Enable or Disable Non uniform Memory Access NUMA Set this value to Enable Disable 6 4 4 Memory Configuration You can use this screen to select options for the Memory Configuration Use the up and down Arrow keys to select an item Use the and keys to change the value of the selected option A description of the selected item...

Page 72: ...h sockets get a chunk of local memory below 4GB Set this value to Enable Disable Channel Interleaving Select Channel Interleaving setting Set this value to Auto 1 way Interleave 2 way Interleave 3 way Interleave 4 way Interleave Rank Interleaving Select Rank Interleaving setting Set this value to Auto 1 way Interleave 2 way Interleave 4 way Interleave 8 way Interleave ...

Page 73: ...age The screen is shown below IIO0 Configuration The screen is shown below IIO1 Configuration The screen is shown below Intel VT for Directed I O VT d The screen is shown below PCIe x8 to aDB 9710 Selects PCIe port Bifurcation for selected slot s Set this value to Auto x8 x4x4 PCIe x16 to aDB 9710 Selects PCIe port Bifurcation for selected slot s Set this value to Auto x16 x8x8 x8x4x4 x4x4x8 x4x4x...

Page 74: ... Arrow keys to select an item Use the and keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on this page The screen is shown below Configure SATA as This will configure SATA as IDE RAID or AHCI Set this value to IDE AHCI RAID ...

Page 75: ...se this screen to specify options for the Server Management settings Use the up and down Arrow keys to select an item Use and keys to change the value of the selected option The settings are described in the following pages The screen is shown as below ...

Page 76: ...s the below Setup Prompt Timeout It s the number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Use the and keys to change the value of this item Quiet Boot This item allows system BIOS to show the boot up splash logo When it is set to Enabled the logo that in system BIOS will be shown during display outputs Boot Option Priorities It shows the boot priority of bo...

Page 77: ...nd User passwords activate two different levels of password security If you select password support you are prompted for 3 to 20 characters password Type the password on the keyboard The password doesn t appear on the screen when typed Make sure you write it down If you forget it you must drain NVRAM and re configure it Administrator Password Use this option to set a password for administrator wit...

Page 78: ... When you have completed the system configuration changes select this option to leave setup utility and reboot the computer to let new system configuration parameters can take effect When selecting this item and then press Enter The below message will be shown up and wait for the confirmation Save Changes and Exit OK Cancel Select OK and press Enter to save changes and exit It will keep booting th...

Page 79: ...pt resetting system System will always be reset after selecting this item no matter what change is made Discard Changes and Reset It has the same function as Discard Changes and Exit except resetting system System will always be reset after selecting this item and will not save any configuration Save Changes Save the changes done so far to any of setup options Discard Options Discard the changes d...

Page 80: ...channel 1 2 and 2 user IDs for SOL You can refer to the following sections for more detailed information Note SOL does not support simultaneous login of more than one user 7 1Preparation For SOL Connection First of all you need to prepare a remote client with Linux OS and connect to the network 7 2Configure The Remote Client 7 2 1 Install IPMItool For The Remote Client You can download the latest ...

Page 81: ...SOL on COM1 only 7 3 2 Linux GRUB Settings GRUB supports sending its messages to the serial console The following lines should be added to the top of the boot grub grub conf file default 1 timeout 5 serial unit 1 speed 115200 word 8 parity no stop 1 terminal timeout 15 serial console The following parameters need to be passed to each instance of the Linux kernel They should be added to the kernel ...

Page 82: ...r to the following table for the Cipher Suite Id ID Characteristics Cipher Suite Authentication Algorithm Integrity Algorithm s Confidentiality Algorithm s 0 straight password 00h 00h 00h RAKP none None None 1 S 01h 00h 00h None None 2 S A 01h 01h 00h None 3 S A E 01h 01h 01h AES CBC 128 4 S A E 01h 01h 02h xRC4 128 5 S A E 01h 01h 03h RAKP HMAC SHA1 HMAC SHA1 96 xRC4 40 6 S 02h 00h 00h None None ...

Page 83: ...ow are 2 samples to establish the SOL session via channel 1 with default user name and password Sample Establish a non nncrypted RMCP SOL session ipmitool I lanplus H 172 17 172 134 C 0 U adlinkuser P adlinkuser sol activate Establish an encrypted RMCP SOL session ipmitool I lanplus H 172 17 172 134 C 3 k gkey U adlinkuser P adlinkuser sol activate For more details on IPMI commands please visit th...

Page 84: ...able on the ADLINK website Please visit the aTCA 9710 product web site for more details www adlinktech com We recommend using all the drivers provided on the ADLINK website to ensure driver compatibility Contact ADLINK to get support for other operating system ...

Page 85: ...pment should be noted 10 If the equipment is not use for long time disconnect the equipment from mains to avoid being damaged by transient overvoltage 11 Never pour any liquid into openings this could cause fire or electrical shock 12 Never open the equipment For safety reason the equipment should only be opened by qualified service personnel 13 If one of the following situations arises get the eq...

Page 86: ...Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd Address 上海市浦东新区张江高科技园区芳春路 300 号 201203 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology GmbH Address Hans Thoma Strasse 11 D 68163 Mannheim Germany Tel 49 621 43214 0 Fax 49 ...

Reviews: