background image

 

 

AmITX-BT-I

 

Page 55

 

8.3.5.

 

USB  

Feature  

Options  

Description  

USB Info 

only 

USB Module Version Info 

only 

USB Devices 

Info only 

Drives, keyboards, mouse, hubs 

Legacy USB Support 

Enabled  

Disabled  
Auto 

Enables legacy USB support. 
Auto option disables legacy support if no USB devices are 
connected.  
Disable option will keep USB devices available only for EFI 
applications and setup. 

XHCI Hand-off 

Enabled 

Disabled 

This is a workaround for OSes without XHCI hand-off support. The 
XHCI ownership change should be claimed by the XHCI OS driver. 

EHCI Hand-off 

Enabled 

Disabled 

This is a workaround for OSes without EHCI hand-off support. The 
EHCI ownership change should be claimed by the EHCI OS driver. 

USB Mass Storage Driver Support 

Enabled 

Disabled 

Enable/Disable USB mass storage driver support. 

Chipset USB Configuration 

Submenu 

 

USB hardware delays and time-outs: 

Info only 

USB transfer time-out 

1 sec 
5 sec 
10 sec 

20 sec 

The time-out value for control, bulk, and interrupt transfers 

Device reset time-out 

10 sec 

20 sec 

30 sec 
40 sec 

USB mass storage device Start Unit command time-out. 

Device power-up delay 

Auto 

Manual 

Maximum time the device will take before it properly reports itself to 
the Host Controller. 'Auto' uses default value: for a Root port it is 100 
ms, for a Hub port the delay is taken from Hub descriptor. 

Mass Storage Devices 

Info only 

List current USB mass storage devices. 

8.3.5.1.

 

USB > Chipset USB Configuration 

Feature  

Options  

Description  

USB Configuration 

Info only 

XHCI Mode 

Enabled 
Disabled 

 

Mode of operation of xHCI controller. 

USB 2.0 (EHCI) Support 

Enabled 

Disabled

 

Control the USB EHCI (USB 2.0) functions. One EHCI controller 
must always be enabled. 

USB Per Port Control 

Enabled 

Disabled 

Control each of the USB ports (0~3). Enable: Enable USB per 
port; Disable: Use USB port x settings. 

USB Port #0~3 

Enabled 

Disabled

 

Enable/Disable USB port 0-3. 

Summary of Contents for AmITX-BT-I

Page 1: ...AmITX BT I User s Manual Mini ITX Embedded Motherboard with 4th Gen Intel Atom Processor E3800 Manual Revision 1 00 Revision Date November 19 2015 Part Number 50 1X011 1000 ...

Page 2: ...Page 2 AmITX BT I Revision History Revision Description Date By C J 11 19 5 1 0 2 Initial release 0 0 1 ...

Page 3: ...bility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the European Union s Restriction of Hazardous Substances RoHS directive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enforced measures to ensure that ou...

Page 4: ...tion 9 2 11 Operating Temperatures 10 2 12 Environmental 10 2 13 Operating Systems 10 2 14 Power Consumption 10 2 15 Functional Diagram 12 3 Mechanical Layout 13 3 1 Connector Locations 13 3 2 Mechanical Dimensions 14 3 3 Thermal Solutions 16 4 Connectors and Jumpers 17 4 1 Rear IO Connectors 17 4 1 1 DC Power Inlet 17 4 1 2 Serial COM Ports COM1 COM2 18 4 1 3 VGA Connector VGA 19 4 1 4 HDMI Conne...

Page 5: ... ATX AT Mode Jumper Selection JPY1 33 4 3 2 Clear CMOS and BIOS Default JP5 33 4 3 3 Reset BIOS Defaults JP6 33 4 3 4 SATA2 mSATA Select JP1 33 4 3 5 LVDS Backlight Power Jumper Selection JP2 34 4 3 6 LVDS Panel Power Jumper Selection JP3 34 4 3 7 LVDS Backlight Enable Jumper Selection JP4 34 4 3 8 Serial Port Mode Switch Setting SW14 SW10 SW11 35 4 3 9 BIOS Switch Setting SW1 35 4 4 Onboard Conne...

Page 6: ...ion 47 8 2 5 SOC Information 47 8 2 6 System Management 48 8 2 7 System Date and Time 51 8 3 Advanced 52 8 3 1 CPU 52 8 3 2 Memory 52 8 3 3 Graphics 53 8 3 4 SATA 54 8 3 5 USB 55 8 3 6 Network 56 8 3 7 PCI and PCIe 56 8 3 8 Super IO 59 8 3 9 ACPI and Power Management 60 8 3 10 Sound 60 8 3 11 Serial Port Console 61 8 3 12 Thermal 62 8 3 13 Miscellaneous 62 8 4 Boot 64 8 4 1 Boot Configuration 64 8...

Page 7: ...ts and SATA 3 Gb s ports Support is provided for SMBus and I2C The module is equipped with SPI AMI EFI BIOS supporting embedded features such as hardware monitor and watchdog timer CPU Intel Bay Trail SoC Core Speed Total Design Power AmITX BT I E3845 Atom E3845 4 cores 1 91 GHz 10W AmITX BT I E3827 Atom E3827 2 cores 1 75 GHz 8W AmITX BT I E3826 Atom E3826 2 cores 1 46 GHz 7W AmITX BT I E3825 Ato...

Page 8: ...ion cache and 24 kB 6 way L1 write back data cache Memory Dual channel non ECC 1066 1333 MHz DDR3L memory up to 8GB in dual stacked SODIMM sockets Embedded BIOS AMI EFI in 8MB SPI BIOS 2 2 Rear I O Connectors Display VGA and HDMI LAN Dual GbE RJ 45 USB 4x USB 3 0 Serial 1x RS 232 COM1 supports console redirection 1x RS 232 422 485 Aduio Line Out Mic In Power Screw Jack for 12V DC in 2 3 Internal H...

Page 9: ...are acceleration including support for H 264 MPEG2 VC 1 WMV and VP8 formats Video encode hardware acceleration including support for H 264 MPEG2 and MVC formatsPlayback of Blu ray disc S3D content using HDMI 1 4a spec compliant with 3D Note Availability of features may vary between operating systems Display Interface support VGA Analog VGA supporting resolutions up to 2560x1600 x24bpp at 60 Hz HDM...

Page 10: ...ting Systems Standard Support Windows 7 8 32 64 bit Linux 32 64 bit Extended Support BSP WES7 WE8S WEC7 Linux VxWorks 2 14 Power Consumption System Configuration Processor Intel Atom Processor E3845 2M Cache 1 91 GHz Memory Slot1 Transcend 8G 2Rx8 DDR3L 1600 SODIMM Memory Slot2 Transcend 8G 2Rx8 DDR3L 1600 SODIMM Graphics Intel HD Graphics Storage WD WD3200BUDT 320GB 2 5 SATA 3Gb s HDD Monitor Ben...

Page 11: ... Memory Slot2 Transcend 8G 2Rx8 DDR3L 1600 SODIMM Graphics Intel HD Graphics HDD WD WD3200BUDT 320GB 2 5 SATA II HD Monitor Hanns G HZ222 Power Supply FSP FSP600 80PSA 600W ATX Video Resolution 1680 x 1050 32 bit Power State Current A Voltage V Power W Windows 7 Idle 0 58 12 03 6 9774 Windows 7 Typical 0 89 12 03 10 7067 Windows 7 Max loading 1 02 12 03 12 2706 S3 0 25 5 00 1 25 ...

Page 12: ...Page 12 AmITX BT I 2 15 Functional Diagram ...

Page 13: ...VGA HDMI LAN USB 3 0 Line out Mic in LAN USB 3 0 PCIe x1 mSATA Slot Stacked SODIMMs 2x SATA 3Gb s Mini PCIe Front Panel Connector Audio Connector 12V DC in 4x COM Ports ATX Power Feature Connector LVDS USB Header SPI Header DB40 Connector TPM Header PS 2 KB MS SATA Power SIM Card Slot ...

Page 14: ...Page 14 AmITX BT I 3 2 Mechanical Dimensions Top View Dimensions mm All Φ tolerances 0 05mm Other tolerances 0 2mm ...

Page 15: ...AmITX BT I Page 15 Side View With AmITX BT_4010 CJ Cooler Standard Temp 0 C to 60 C With AmITX BT_4020 CJ Cooler Extreme Rugged 40 C to 85 C Intel Atom E38xx only Dimensions mm All tolerances 0 2mm ...

Page 16: ... Temp 0 C to 60 C P N 32 20493 1000 AmITX BT_4010 CJ Cooler with Fan Standard Temp 0 C to 60 C P N 32 20493 0000 AmITX BT_CU CJ Passive Heatsink Standard Temp 0 C to 60 C P N 32 20510 0000 AmITX BT_4020 CJ Cooler with Fan Extreme Rugged 40 C to 85 C Atom E38xx only P N 32 20494 0000 ...

Page 17: ...or Maximum current draw is 10A Note Either the DC Power Inlet or the internal ATX Power Connector ATX_PWR must be used to supply the motherboard with 12V 5 JACK1 PWR JACK_P1 VCC 1 GND1 2 GND2 3 Caution Hot plugging the power supply is not supported Doing so may damage the board Only connect ONE power supply to the board Connecting power to both the 12V DC inlet and the internal ATX Power Connector...

Page 18: ...RS 422 RS 485 1 DCD Data Carrier Detect TX RTX 2 RXD Receive Data TX RTX 3 TXD Transmit Data RX N A 4 DTR Data Terminal Ready RX N A 5 GND N A N A 6 DSR Data Set Ready N A N A 7 RTS Request To Send N A N A 8 CTS Clear To Send N A N A 9 RI Ring Indicator N A N A SW14 Switch for mode selection of COM1 default RS 232 SW14 ...

Page 19: ... DDC2B DATA HSYNC 13 14 VSYNC DDC2B CLK 15 4 1 4 HDMI Connector Pin Signal Pin Signal 1 TMDS Data2 2 TMDS Data2 Shield 3 TMDS Data2 4 TMDS Data1 5 TMDS Data1 Shield 6 TMDS Data1 7 TMDS Data0 8 TMDS Data0 Shield 9 TMDS Data0 10 TMDS Clock 11 TMDS Clock Shield 12 TMDS Clock 13 CEC 14 Reserved 15 SCL 16 SDA 17 DDC CEC Ground 18 5 V Power 19 Hot Plug Detect ...

Page 20: ...N_MDI1 7 LAN_MDI3 8 LAN_MDI3 LED1 Speed LED2 Link Activity Status Description Status Description Off 10 Mb connection Off No Link Green 100 Mb connection Orange Linked Orange 1 Gb connection Blinking Data Activity 4 1 6 USB 3 0 Connectors USB1 4 Pin Signal 1 USB3 0_P5VA 2 USB2_CMAN 3 USB2_CMAP 4 GND 5 USB3A_CMRXN 6 USB3A_CMRXP 7 GND 8 USB3A_CMTXN 9 USB3A_CMTXP ...

Page 21: ...X power supply Note Either the DC Power Inlet or the internal ATX Power Connector ATX_PWR must be used to supply the motherboard with 12V 5 Pin Signal Pin Signal 1 SB5V 8 P_OK 2 GND 9 PS_ON 3 GND 10 12V 4 GND 11 12V 5 GND 12 12V 6 GND 13 12V 7 3 3V 14 5V CAUTION Only connect ONE power supply to the board Connecting power to both the 12V DC inlet and the internal ATX Power Connector may damage the ...

Page 22: ...n the AmITX BT I and support SATA Gen2 3 0 1 5Gb s Note If mSATA is installed SATA2 is disabled See 4 3 4 SATA2 mSATA Select JP1 Pin Signal 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 4 2 3 SATA Power Connector ST_PWR Pin Signal 1 12V 2 GND 3 5V 4 GND 5 3 3V Motherboard ATX Power Connector ATX_PWR ATX Power Supply 5 4 3 2 1 SATA Power SATA2 SATA1 ...

Page 23: ...tivity during S3 S4 state CN35 BH_10_S2mm_N9 1 3 5 7 2 4 6 8 10 85USB2_P3_DP_R P5V_USB2 85USB2_P3_DN_R P5V_USB2 85USB2_P2_DN_R 85USB2_P2_DP_R Pin Signal Pin Signal 1 P5V_USB 2 P5V_USB 3 P2_DN_R 4 P3_DN_R 5 P2_DP_R 6 P3_DP_R 7 GND 8 GND 9 KEY 10 GND USB Cable optional USB 2 0 Header to 2x Female Type A Cable length 200mm P N 30 20874 1000 HDD SSD Power Motherboard SATA Power Connector HDD SSD Power...

Page 24: ... 2 0 pitch standard wafer connector Note Signals shared with Audio Connector on Rear I O Signal Pin Pin Signal LFE OUT 1 2 CEN OUT AAGND 3 4 AAGND FRONT OUT L 5 6 FRONT OUT R AAGND 7 8 AAGND REAR OUT L 9 10 REAR OUT R SIDE OUT L 11 12 SIDE OUT R AAGND 13 14 AAGND MIC1 L 15 16 MIC1 R AAGND 17 18 AAGND LINE1 L 19 20 LINE1 R MUTE 21 22 AAGND GND 23 24 NC SPDIF OUT 25 26 GND Pin Signal 1 MSCLK 2 V5S_S...

Page 25: ...V 12V power support by BOM option default 5V SW10 Switch for mode selection of COM3 default RS 232 COM4 Supports RS 232 RS 422 RS 485 5V 12V power support by BOM option default 5V SW11 Switch for mode selection of COM4 default RS 232 COM5 Supports RS 232 only 5V 12V power support by BOM option default 5V COM6 Supports RS 232 only 5V 12V power support by BOM option default 5V RS 232 Pin Signal Pin ...

Page 26: ...2V RS 485 COM3 4 only Pin Signal Pin Signal 1 Tx Rx 2 Tx Rx 3 4 5 6 7 8 9 GND 10 5V 12V SW10 SW11 RS 422 485 Mode Select RS 232 default RS 422 RS 485 1 ON ON OFF 2 OFF ON ON See Section 4 3 8 Serial Port Mode Switch Setting SW14 SW10 SW11 COM Cable optional COM Port Cable length 250mm P N 30 20876 0000 ...

Page 27: ...l for both voltages DDC CLK DDC Channel Clock DDC DAT DDC Channel Data Note Type Signal Pin Pin Signal Type Note LVDS LVDS A0 1 16 LVDS B1 LVDS LVDS LVDS A0 2 17 POWER GND PWR Max 0 5A LVDS LVDS A1 3 18 LVDS B2 LVDS LVDS LVDS A1 4 19 LVDS B2 LVDS LVDS LVDS A2 5 20 LVDS BCLK LVDS LVDS LVDS A2 6 21 LVDS BCLK LVDS Max 0 5A PWR POWER GND 7 22 LVDS B3 LVDS LVDS LVDS ACLK 8 23 LVDS B3 LVDS LVDS LVDS ACL...

Page 28: ... PWR GND Max 0 5A 10 OT BKLT_CTL 3 3V level Signal Description BKLT_EN Backlight Enable signal active low Optional to invert this signal to active high BKLT_EN by jumper BKLT_PWR Backlight Power switchable by jumper either 5V default or 12V Maximum 1A per pin for both voltages BKLT_CTL Backlight control PWM signal to implement voltage in the range 0 3 3V See Chapter 4 3 Jumper and Switch Settings ...

Page 29: ... 12 5V PWR 2 13 SATA_LED 25 25mA O 14 SUS_LED O 7mA 3 15 GND PWR 16 PWRBTN_IN I 17 RSTIN I 18 GND PWR 19 SB3V3 PWR 20 LINE2 R 21 AGND PWR 22 AGND PWR 23 MIC2 L AI 24 MIC2 R AI Note 1 5V SB5V 5V supplies for external devices SB5V is supplied during power down to allow wakeup on USB device activity during S3 S4 state Note 2 Maximum load is 1A Note 3 SUS_LED System Power LED Connect to the power stat...

Page 30: ...l Pull U D Ioh Iol Type Note Pin Signal Type Ioh Iol Pull U D Note 1 CASE_OPEN PU 2M I 2 SMBC OT 4mA PU 10K 1 3 GND PWR 4 SMBD OT 4mA PU 10K 1 5 TEMPS I 2 6 I2CC OT PU 10K 1 7 EXT_BAT PWR 8 I2CD OT PU 10K 1 9 SB3V3 PWR 10 SB5V PWR 11 GND PWR 12 GND PWR 13 GPIO0 PU10K3V3 IOT 14 GPIO1 IOT PU10K3V3 15 GPIO2 PU10K3V3 IOT 16 GPIO3 IOT PU10K3V3 17 GPIO4 PU10K3V3 IOT 18 GPIO5 IOT PU10K3V3 19 GPIO6 PU10K3...

Page 31: ...l must be NC MOSI Master Output Slave Input ISOLATE The ISOLATE input active low is normally NC but must be connected to GND when loading SPI flash Power Supply to the Motherboard must be turned off when loading SPI flash The pull up resistor is connected via diode to 5VSB MISO Master Input Slave Output SPI_IO2_ WP SPI Data I O A bidirectional signal used to support the new Dual IO Fast Read Quad ...

Page 32: ... 28 BMC Program interface continued OCD0B Include a jumper to connect OCD0A via 1K0 pull up to 3 3V_BMC 9 GND 29 PWRBTN 10 CB_RESET Platform Reset 30 SYS_RESET 11 RST 31 CB_RESET 12 CLK33_LPC 32 CB_PWROK 13 LPC_FRAME 33 SUS_S3 14 LPC_AD3 34 SUS_S4 15 LPC_AD2 35 Test points SUS_S5 16 LPC_AD1 always power 3 3V provide from COM module 36 POSTWDT_DIS Connect to Jumper for Debug 17 LPC Bus LPC_AD0 37 S...

Page 33: ...1 ATX AT Mode 1 2 ATX default 2 3 AT 4 3 2 Clear CMOS and BIOS Default JP5 JPY1 ATX AT Mode 1 2 Normal default 2 3 Clear CMOS 4 3 3 Reset BIOS Defaults JP6 JPY1 ATX AT Mode 1 2 Normal default 2 3 Reset BIOS Defaults 4 3 4 SATA2 mSATA Select JP1 JP1 SATA2 mSATA Select 1 2 SATA2 default 2 3 mSATA ...

Page 34: ...ction JP2 JP1 Backlight Power 1 2 12V 2 3 5V default 4 3 6 LVDS Panel Power Jumper Selection JP3 JP2 Panel Power 1 2 5V 2 3 3 3V default 4 3 7 LVDS Backlight Enable Jumper Selection JP4 JP4 Backlight Power 1 2 Active High Convert 2 3 Active LowNormal default ...

Page 35: ...S 232 default RS 422 RS 485 1 ON ON OFF 2 OFF ON ON SW10 SER3 MODE SEL RS 232 default RS 422 RS 485 1 ON ON OFF 2 OFF ON ON SW11 SER4 MODE SEL RS 232 default RS 422 RS 485 1 ON ON OFF 2 OFF ON ON 4 3 9 BIOS Switch Setting SW1 SW1 ON default Boot from SPI0 OFF Boot from SPI1 SW14 SW10 SW11 SW1 ...

Page 36: ...N6850 10S10B 01G B V9 01 YOUNG YAK YY 1970H 2 5P PH2 0 30 20874 1000 optional SATA Power CN29 JVE 24W1170 05S10 01T 3 4 CS01 YOUNG YAK YY 1970H 2 5P PH2 0 30 20875 0000 standard SATA CN16 17 WIN WIN WATM 07DBN4B2B8UW 30 10057 0600 standard DB 40 Molex 502790 4091 30 30016 0000 optional LVDS CN21 JVE FI X30SSLA HF WELL LIN ENTERPRISE WL1058 HL 30P PH1 0 LVDS Auxiliary CN45 Molex 53261 1071 WELL LIN...

Page 37: ...ocedure for Windows 7 32 bit is outlined below Install the Windows operating system before installing any driver Most standard I O device drivers are installed during Windows installation 1 Install the Chipset driver by running the program 1 Chipset Intel_Chipset_Device_Software_WinAllOS_ v10 0 20 SetupChipset exe Follow the instructions given and reboot when instructed 2 Install the Display drive...

Page 38: ...rnal logic to boot from fail safe BIOS Flash area 1kB Flash area for customer data 128 Bytes Protected Flash area Keys IDs etc can be stored in a write and clear protectable region Board Identify Vendor Board Serial number Production Date Main current voltage Monitors drawn current and main voltages For a detailed description of SEMA features and functionality please refer to the SEMA Technical Ma...

Page 39: ...Main Current MSB_n 8 LSB_n x 8 06mA 6 1 3 BMC Status This register shows the status of BMC controlled signals on the cExpress BT Status Bit Signal 0 WDT_OUT 1 LVDS_VDDEN 2 LVDS_BKLTEN 3 BIOS_MODE 4 POSTWDT_DISn 5 SEL_BIOS 6 BIOS_DIS0n 7 BIOS_DIS1n 6 1 4 Exception Codes In case of an error the BMC drives a blinking code on the blue Status LED LED1 The same error code is also reported by the BMC Fla...

Page 40: ...CAL_TEMP 19 NO_CB_PWROK 20 NO_HW_PWORK 21 NO_V1P24A_PG 6 1 5 BMC Flags The BMC Flags register returns the last detected Exception Code since power up and shows the BIOS in use and the power mode Bit Description 0 4 Exception Code 6 0 AT mode 1 ATX mode 7 0 Standard BIOS 1 Fail safe BIOS ...

Page 41: ...High Bios 0K 1MB 1MB DOS DRAM 7 2 I O Map 7 2 1 I O Map Hex Range Device 20h 21h 24h 25h 28h 29h 2Ch 2Dh 30h 31h 34h 5h 38h 39h 3Ch 3Dh 8259 Master 40h 43h 50h 53h 8254s 60h 64h PS2 Control 61h 63h 65h 67h NMI Controller 70h 77h RTC 80h 83h Port 80h 92h Init Register A0h A1h A4h A5h A8h A9h ACh ADh B0h B1h B4h B5h B8h B9h BCh BDh 4D0h 4D1h 8259 Slave 2E8h 2FFh COM2 3F8h 3FFh COM1 B2h B3h Active Po...

Page 42: ...el Port LPT IRQ5 via SERIRQ PIRQ Note 1 6 Generic IRQ6 via SERIRQ PIRQ Note 1 7 Generic IRQ7 via SERIRQ PIRQ Note 1 8 Real time clock N A No 9 Generic IRQ9 via SERIRQ PIRQ Note 1 10 Generic IRQ10 via SERIRQ PIRQ Note 1 11 Generic IRQ11 via SERIRQ PIRQ Note 1 12 PS 2 Mouse IRQ12 via SERIRQ PIRQ Note 1 13 Math Processor N A No 14 Primary IDE controller IRQ14 via SERIRQ PIRQ Note 1 15 Secondary IDE c...

Page 43: ...A Note 1 11 N A N A Note 1 12 PS 2 Mouse IRQ12 via SERIRQ PIRQ Note 1 13 N A N A Note 1 14 N A N A Note 1 15 N A N A Note 1 16 N A PCIE Port 1 2 3 4 eMMC IGD PCI Slot 1 2 3 4 Note 1 17 N A PCIE Port 1 2 3 4 SDIO Device PCI Slot 1 2 3 4 Note 1 18 N A PCIE Port 1 2 3 4 SD Device PCI Slot 1 2 3 4 Note 1 19 N A PCIE Port 1 2 3 4 AHCI controller PCI Slot 1 2 3 4 Note 1 20 N A Gbe controller xHCI contro...

Page 44: ... 18h 00h Internal Serial IO SIO DMA 00h 18h 01h Internal Serial IO SIO I2C Port 1 00h 18h 02h Internal Serial IO SIO I2C Port 2 00h 1Ah 00h Internal Trusted Execution Engine 00h 1Bh 00h Internal HD Audio 00h 1Ch 00h Internal PCI Express Root port 1 00h 1Ch 01h Internal PCI Express Root port 2 00h 1Ch 02h Internal PCI Express Root port 3 00h 1Ch 03h Internal PCI Express Root port 4 00h 1Dh 00h Inte...

Page 45: ...Host 1 SDIO SD Host 2 SD Card SATA Controller PCI to PCI Bridge xHCI Host Low Power Audio Engine TXE HDA Int0 INTE 20 INTF 21 INTF 21 INTG 22 Int1 INTB 17 Int2 INTC 18 INTC 18 Int3 INTD 19 INT Line EHCI Controller SMBus Controller GbE Controller LPSS2 DMA LPSS2 I2C 1 LPSS2 I2C 2 Int0 INTH 23 INTE 20 INTB 17 Int1 INTC 18 Int2 INTD 19 Int3 INTC 18 7 5 SMBus Slave Address Device Address DIMM A A0h DI...

Page 46: ...s described in the right hand column of the respective table Main Advanced Boot Security Save Exit System Information Processor Information VGA Firmware Version Memory Information SOC Information System Management System Date System Time CPU Memory Graphics SATA USB Network PCI and PCIe Super IO ACPI and Power Management Sound Serial Port Console Thermal Trusted Computing Miscellaneous PPM Configu...

Page 47: ...uilt 8 2 2 Processor Information Feature Options Description CPU Brand String Info only Display CPU brand name Max CPU Speed Info only Display CPU frequency CPU Signature Info only Display CPU ID Number of Processors Info only Display number of processor 8 2 3 VGA Firmware Version Feature Options Description IGFX VBIOS Version IGFX GOP Version Info only Display legacy VBIOS or GOP driver version 8...

Page 48: ... Features Read only Display SEMA features 8 2 6 2 System Management Temperatures and Fan Speed Feature Options Description Temperatures and Fan Info only Board Temperatures Info only Current Read only Display current board temperature Startup Read only Display board startup temperature Min Read only Display board min temperature Max Read only Display board max temperature CPU Fan Speed Read only D...

Page 49: ...ned value specifies the time in seconds the system is running in S0 state This counter is cleared when the system is removed from the external power supply Power Cycles Read only The returned value specifies the number of times the external power supply has been shut down Boot Cycles Read only The Bootcounter is increased after a HW or SW Reset or after a successful power up Boot Reason Read only ...

Page 50: ...klight Bright 255 The value range starts at 0 and ends at 255 8 2 6 8 System Management Smart Fan Feature Options Description Smart Fan Info only CPU Smart FanTemperature Source CPU Sensor System Sensor Select CPU smart fan source CPU Fan Mode AUTO Smart Fan Fan Off Fan On Select CPU fan mode CPU Trigger Point 1 Read only Trigger Temperature 15 Specifies the temperature threshold at which the BMC ...

Page 51: ...m Date Day of Week MM DD YYYY Requires the alpha numeric entry of the day of the week day of the month calendar month and all 4 digits of the year indicating the century and year Fri XX XX 20XX System Time HH MM SS Presented as a 24 hour clock setting in hours minutes and seconds ...

Page 52: ...ly Display Intel VT x Technology support 64 bit Info only Display 64 bit support L1 Data Cache Info only Display cache info L1 Code Cache Info only Display cache info L2 Cache Info only Display cache info L3 Cache Inf o only Display cache info Limit CPUID Maximum Disabled Enabled Disabled for Windows XP SB CRID Revision ID CRID 0 CRID 1 CRID 2 Select the Revision ID Revision ID CRID 0 CRID 1 CRID ...

Page 53: ...l Graphics Device DVMT Total Gfx Mem 256MB Select DVMT5 0 Total Graphic Memory size used by the Internal Graphics Device LVDS Backlight Mode BMC Mode GTT Mode Select LVDS backlight control function DDI function choose DisplayPort HDMI LVDS Choose DisplayPort HDMI or LVDS AMI Graphics Output Protocol Policy UEFI GOP only Submenu User select monitor output by graphics output protocol GT Power Manage...

Page 54: ... on the integrated display panel 8 3 4 SATA Feature Options Description SATA Info only SATA Controller s Enabled Disabled Enable Disable Serial ATA SATA Mode Selection IDE Mode AHCI Mode Select IDE AHCI SATA Test Mode Enabled Disabled Test Mode enable disable SATA Controller Speed Gen1 Gen2 Gen3 SATA speed support Gen1 or Gen2 SATA Port Configuration Submenu 8 3 4 1 SATA SATA Port Configuration Fe...

Page 55: ... hardware delays and time outs Info only USB transfer time out 1 sec 5 sec 10 sec 20 sec The time out value for control bulk and interrupt transfers Device reset time out 10 sec 20 sec 30 sec 40 sec USB mass storage device Start Unit command time out Device power up delay Auto Manual Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value ...

Page 56: ...Disabled Enable or Disable the PCI Express port 1 in the chipset SERR Generation Enabled Disabled Enables or Disables PCI Device to generate SERR PCI Express Settings Info only Relaxed Ordering Disabled Enabled Enables or Disables PCI Express device relaxed ordering Extended Tag Disabled Enabled If Enabled allows device to use 8 bit tag field as a requester No Snoop Disabled Enabled Enables or Dis...

Page 57: ...was unsuccessful Link Training Timeout Us 1000 Defines number of microseconds software will wait before polling Link Training bit in Link Status register Value range from 10 to 10000 uS Unpopulated Links Keep Link ON Disabled In order to save power software will disable unpopulated PCI Express links if this option set to Disabled Restore PCIE Registers Enabled Disabled On non PCI Express aware OSe...

Page 58: ...d Enabled Enable or disable PCI Express Device Fatal Error Reporting NFER Disabled Enabled Enable or disable PCI Express Device Non Fatal Error Reporting CER Disabled Enabled Enable or disable PCI Express Device Correctable Error Reporting SEFE Disabled Enabled Enable or disable Root PCI Express System Error on Fatal Error SENFE Disabled Enabled Enable or disable Root PCI Express System Error on N...

Page 59: ... 6 7 10 11 12 Enable Disable Serial Port 2 COM1 Fixed configuration of serial port Select an optimal setting for Super IO device Serial Port 3 Configuration Serial Port Device Settings Change Settings Enabled Disabled IO 3E8h IRQ 6 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 Enable Disable Serial Por...

Page 60: ...gement Feature Options Description ACPI and Power Management Info only Enable ACPI Auto Configuration Enabled Disabled Enables or disables BIOS ACPI Auto Configuration Enable Hibernation Enabled Disabled Enables or disables system s ability to hibernate OS S4 Sleep State This option may be not effective with some OSes ACPI Sleep State Suspend Disabled S3 Suspend to RAM Select the highest ACPI slee...

Page 61: ... Terminal Type VT100 VT100 VT UTF8 ANSI VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes ANSI Extended ASCII char set Bits per second 9600 19200 38400 57600 115200 Selects serial port transmission speed The speed must be matched on the remote computer Long or noisy lines may require lower speeds Data Bi...

Page 62: ...ooling Trip Point Passive Trip Point Disabled 90 C 80 C This value controls the temperature of the ACPI Passive Trip Point the point at which the OS will begin throtting the processor Passive TC1 Value 1 This value sets the TC1 value for the ACPI Passive Cooling Formula Range 1 16 Passive TC2 Value 5 This value value sets the TC2 value for the ACPI Passive Cooling Formula Range 1 16 Passive TSP Va...

Page 63: ...5 Support for SDCard Enabled Disabled Disable Enable SDR25 capability in SD Card controller DDR50 Support for SDCard Enabled Disabled Disable Enable DDR50 capability in SD Card controller MIPI HIS Support Enabled Disabled MIPI HIS support enable disable LPSS Configuration Info only LPSS DMA 1 Support Enabled Disabled LPSS DMA 1 support enable disable LPSS HSUART 1 Support Enabled Disabled LPSS HSU...

Page 64: ... only CSM Parameters Submenu CSM configuration Enable Disable Option ROM execution settings etc 8 4 1 1 Boot Configuration CSM Parameters Feature Options Description Compatibility Support Module Configuration Info CSM Support Enabled Disable Enable Disable CSM Support CSM16 Module Version Info only GataA20 Active Upon Request Always Upon Request GA20 can be disabled using BIOS services Always do n...

Page 65: ...r mode with enrolled Platform Key PK 2 CSM function is disabled Secure Boot Mode Standard Custom Secure Boot mode selector Custom Mode enables users to change Image Execution policy and manage Secure Boot keys 8 6 Save Exit Feature Options Description Save Changes and Exit Yes No Exit system setup after saving the changes Discard Changes and Exit Yes No Exit system setup without saving any changes...

Page 66: ...urce settings à Always install and operate equipment near an easily accessible electrical socket outlet à Secure the power cord do not place any object on over the power cord à Only install attach and operate equipment on stable surfaces and or recommended mountings à If the equipment will not be used for long periods of time turn off and unplug the equipment from its power source Never attempt to...

Page 67: ...Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address Rm 801 Power Creative E No 1 B D Shang Di East Rd Beijing 100085 China Tel 86 10 5885 8666 Fax 86 10 5885 8625 Email market adlinktech com ADLINK Technology Shenzhen Address 2F C Block Bldg A1 Cyber Tech Zone Gao Xin Ave Sec 7 High Tech Industrial...

Page 68: ...63 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Address 84 Genting Lane 07 02A Cityneon Design Centre Singapore 349584 Tel 65 6844 2261 Fax 65 6844 2263 Email singapore adlinktech com ADLINK Technology Singapore Pte Ltd Indian Liaison Office Address 50 56 First Floor Spearhead Towers Margosa Main Road between 16th 17th Cross Malleswaram Bangalore 560 055 India Tel 91 80 65605817 ...

Reviews: