OPERATING INSTRUCTIONS

DMX Addressing: Operating through a DMX controller gives the user the freedom to create custom 

programs tailored to their own individual needs. 

1.  To run your fixture in DMX mode, press the UP or DOWN buttons until “Set ADDR” is displayed. 

Press the ENTER button and “Set ADDR XXX” will be displayed. “XXX” represents the currently 

selected address.

2.  Use the UP or DOWN buttons to find your desired DMX address and press ENTER to save the 

address.

3.  Please refer to the DMX Traits section of this manual for detailed information.

4.  After you have chosen your desired DMX Channel mode (see below), plug in the fixture via the 

XLR connections to any standard DMX controller.

DMX Channel Mode: The Encore FR50z has 6 DMX channel modes. This submenu will allow you to 

choose the DMX mode with which the fixture will operate.

1.  To select your desired DMX channel mode, press the MODE button until “UserMode” is dis-

played. Press the ENTER button and the currently selected DMX channel mode will be displayed.

2.  Use the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to save 

your selection.

3.  Please refer to the DMX Traits section of this manual for detailed information.

4.  After you have chosen your desired DMX Channel mode, plug in the fixture via the XLR connec-

tions to any standard DMX controller.

DMX State: This setting defines how the fixture will behave when the DMX signal is lost or inter-

rupted. You can also set this as the operating mode you would like the unit to return to when it is 

powered up.

1.  Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed. Press 

the ENTER button. 

2.  Use the UP or DOWN buttons to scroll to “NO DMX” and press ENTER. Use the UP or DOWN 

buttons to toggle between the two choices:

•  “Black” (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into 

stand by mode.

•  “Hold” (Last State) - If the DMX signal is lost or interrupted, the fixture will stay in the most 

recently configured DMX set up.

3.  Once you have found your desired mode, press ENTER to confirm. Press MODE to exit to the 

main menu.

Summary of Contents for ENC846

Page 1: ...User Manual ENCORE FR50Z...

Page 2: ...tained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving...

Page 3: ...utions 6 Layout 7 DMX Setup 8 System Menu 10 Operating Instructions 12 Primary Secondary Configuration Zoom Adjustment Knob 16 DMX Traits 17 Multi Unit Power Linking Dimmer Curve Chart 18 Barn Door At...

Page 4: ...ual with the unit for future reference Customer Support ADJ provides a customer support line to provide set up help and to answer any ques tion that may arise during set up or initial operation ADJ PR...

Page 5: ...anty you must provide a copy of your proof of purchase invoice You may obtain an R A number by contacting our customer support team on our customer support number All packages returned to the service...

Page 6: ...d for indoor use only Use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply co...

Page 7: ...1 Zoom Adjustment Knob 2 Power In 3 3 Pin DMX In 4 3 Pin DMX Out 5 Power Out 6 Mode Button 7 USB Port 8 Enter Button 9 LCD Menu Control Display 10 Down Button 11 Up Button 12 Barn Door Secure Lock 13...

Page 8: ...g several DMX fixtures The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX l...

Page 9: ...unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR co...

Page 10: ...de 1CH DMX channel mode selection 2CH 2 2CH 3CH 2 3CH 4CH MENU Function NO DMX Lost DMX Black Hold DMX lost status LCD Set Display On Off Display settings Key Lock On Off On1 Flash On Off Temp Celsius...

Page 11: ...rent running time hours Total Tim Total running time hours Last Clea Last running time cleared hours Timer Pin On Off Clear runnung time password 050 Temp Info Temp Info Current LED tem perature Err I...

Page 12: ...the currently selected DMX channel mode will be displayed 2 Use the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to save your selection 3 Please refer to the DMX Traits se...

Page 13: ...the display until the display unlocks Unit Temperature With this function you can switch the temperature display between Celsius or Fahrenheit 1 Plug the fixture in and press the UP or DOWN buttons u...

Page 14: ...switch between ON or OFF To reset the unit to factory settings select ON and press ENTER Press the MODE button to exit the submenu with no changes Time Infomation In this submenu you are able to check...

Page 15: ...ayed Press the MODE button to exit Manual Dimmer Mode 1 Plug the fixture in and press the UP or DOWN buttons until Menu Manual is displayed then press ENTER 2 ManCtrl Dimmer will be displayed Press th...

Page 16: ...is the input and the female XLR connector is the ouput The first unit in the chain primary will use the female XLR connector only and the last unit in the chain will use the male XLR connector only 2...

Page 17: ...Fine 2 2 3 Strobe 000 031 Off 032 063 On 064 095 Variable Strobe slow to fast 096 127 On 128 159 Pulse Effect slow to fast 160 191 On 192 223 Random Strobe slow to fast 224 255 On 3 3 4 Dim Mode 000...

Page 18: ...t sockets The maximum that can be connected is as follows 20 fixtures 120V 40 fixtures 240V After the maximum connected fixtures you will need to use a new power outlet NOTE USE CAUTION WHEN POWER LIN...

Page 19: ...e the Gel Frame in from the top and into the 3 Grooves located closest to the unit 2 Slide the Barn Door in from the top and into the 3 Barn Door Grooves 3 Flip the lens lock back down into place to s...

Page 20: ...20 DIMENSIONAL DRAWINGS...

Page 21: ...uts and outputs are connected does affect the operation of the unit CLEANING Due to fog residue smoke and dust cleaning of the internal and external optical lenses must be carried out periodically to...

Page 22: ...service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement th...

Page 23: ...9 8 L x 9 4 W x 11 7 H 247 8mm L x 238 1mm W x 298 3mm H Colors Warm White DMX Channels 6 DMX Modes 1 2 2 2 3 2 3 4 channels Control RDM Remote Device Management Warranty 2 Year 730 Days Please Note S...

Page 24: ......

Reviews: