B 40
Remote control connector wiring
Vcc and R values must be calculated so as not to exceed a current value
of 35 mA. Higher current will damage the frequency converter.
When the nominal speed is reached, the transistor becomes
conductive («on-state») and Vout = 0 V.
As long as the nominal speed is not reached, the transistor is
blocked («off-state») and Vout = Vcc.
This circuit can not be used for power transfer. For switching of power
circuits an amplification stage is required.
Alcatel Vacuum Technology France - Manuel de l'Utilisateur - ACP 15 / 28 / 40 Series 2
3/3