background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

PROFIBUS Master / Modbus TCP Slave - Converter 

 

Document code: MN67579_ENG     Revision 2.002    Page 3 of 32

 

 

 

SECURITY ALERT: 

 
G

ENERAL 

I

NFORMATION

 

To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and 
safety regulation are required for each individual application. The same applies also when using accessories. 

 

 

I

NTENDED 

U

SE

 

Machines  and  systems  must  be  designed  so  the  faulty  conditions  do  not  lead  to  a  dangerous  situation  for  the  operator  (i.e. 
independent limit switches, mechanical interlocks, etc.). 

 

Q

UALIFIED 

P

ERSONNEL

 

The device can be used only by qualified personnel, strictly in accordance with the specifications. 
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and 
who have appropriate qualifications for their job. 

 

R

ESIDUAL 

R

ISKS

 

The device is state-of-the-art and is safe. The instruments can represent a potential hazard if they are inappropriately installed and 
operated by untrained personnel. These instructions refer to residual risks with the following symbol: 

 

This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or 
death and / or the possibility of damage. 

 

CE

 CONFORMITY

 

The declaration is made by our company. You can send an email to 

[email protected]

  or give us a call if you need it. 

 
 

Summary of Contents for Modbus TCP Slave

Page 1: ...erial www adfweb com Product HD67053 M Bus Master www adfweb com Product HD67551 CANopen www adfweb com Product HD67552 CAN www adfweb com Product HD67553 J1939 www adfweb com Product HD67554 DeviceNe...

Page 2: ...CY 32 Pagina 2 di 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own...

Page 3: ...l interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the install...

Page 4: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Modbus TCP Slave Converter Document code MN67579_ENG Revision 2 002 Page 4 of 32 E...

Page 5: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Modbus TCP Slave Converter Document code MN67579_ENG Revision 2 002 Page 5 of 32 CONNECTION SCHEME Fi...

Page 6: ...OFIBUS Master Modbus TCP Slave Converter allows the following characteristics Triple isolation between Modbus PROFIBUS Modbus Power Supply PROFIBUS Power Supply Mountable on 35mm Rail DIN Power Supply...

Page 7: ...us TCP Slave Converter Document code MN67579_ENG Revision 2 002 Page 7 of 32 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC...

Page 8: ...of the position of the Dip2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the...

Page 9: ...1 Power green ON Powered OFF Not powered ON Powered OFF Not powered 2 Modbus comm green Blinks quickly when Ethernet commands are received Blinks quickly Boot state Blinks very slowly 0 5Hz update in...

Page 10: ...figure Here some codes of cables Belden p n 183079A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable ETHERNET The Ethernet connection must be made using Connector4 of HD67579 A1 with at least a Categ...

Page 11: ...Converter use the available software that runs with Windows called SW67579 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to th...

Page 12: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable PROFIBUS Master Modbus TCP Slave Converter in ord...

Page 13: ...button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the s...

Page 14: ...ide is defined The means of the fields for Modbus TCP Slave are In the field IP ADDRESS the IP address of Modbus TCP side of the converter is defined In the field SUBNET Mask the SubNet Mask of Modbus...

Page 15: ...By pressing the PROFIBUS Network button from the main window for SW67579 Fig 2 the window PROFIBUS Network Fig 4 appears In this window is possible to Modify the PROFIBUS Master Options Master PROFIB...

Page 16: ...ONS By pressing the Master PROFIBUS Options button from the PROFIBUS Network window Fig 4 the PROFIBUS Master Options window appears Fig 5 In this window is possible to set the WatchDog Time for the P...

Page 17: ...ROFIBUS Network window Fig 4 the PROFIBUS Device window appears Fig 6 In this window is possible to Set the PROFIBUS Slave ID ID Slave PROFIBUS Select the Modules present in the PROFIBUS Slave from th...

Page 18: ...lable Modules Fig 7 point 7 Add a Module from the list of GSD file Fig 7 point 6 Remove a Module from selected list Fig 7 point 5 Add all Modules present in the GSD file Fig 7 point 4 Remove all Modul...

Page 19: ...he configuration of the module in hexadecimal The means of the fields are In the field Description of Module a name of the Module is defined In the field Insert the Configuration of Module HEX the con...

Page 20: ...y enable this option is possible to insert manually the parameters of Device and also of the Modules Using the Modify User Parameters Manually button is possible to insert modify the parametrization o...

Page 21: ...w is possible to add modify the User and or Modules Parameters manually i e writing the configuration of the parameters in hexadecimal The means of the fields are In the field Insert the number of Use...

Page 22: ...able for the Module selected Parameters of module Fig 11 point 2 The Configuration of all parameters in RAW for the Module selected Parameters in RAW Hex Fig 11 point 3 The admited value for the selec...

Page 23: ...ter Document code MN67579_ENG Revision 2 002 Page 23 of 32 CAPABILITIES The section Capabilities is used only to show which features baudrates available in the PROFIBUS device The Green Icon indicate...

Page 24: ...Capabilities section to check it In the field Enable Freeze the PROFIBUS Freeze command is enable This option is enable only if the Freeze Mode is supported by the device see Capabilities section to...

Page 25: ...ss the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK tur...

Page 26: ...the updating Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If...

Page 27: ...d with Input Register Status Function not enabled Data in reading Type Address Function Description Holding Register 0 03 Input Bytes 0 1 of PROFIBUS side Holding Register 1 03 Input Bytes 2 3 of PROF...

Page 28: ...er 1 04 Input Bytes 2 3 of PROFIBUS side Input Register 2 04 Input Bytes 4 5 of PROFIBUS side Input Register 121 04 Input Bytes 242 243 of PROFIBUS side Data in writing Type Address Function Descripti...

Page 29: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Master Modbus TCP Slave Converter Document code MN67579_ENG Revision 2 002 Page 29 of 32 MECHANICAL DIMENSION...

Page 30: ...rdering part number is formed by a valid combination of the following HD67579 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67579 PROFIB...

Page 31: ...r European countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to a...

Page 32: ...you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed informat...

Reviews: