CAN
2.0B
29
B
ITS
For CAN 2.0B messages, it is possible to define two type of
filters:
Filters CobID: the DataLogger will accept/discharge
specific CAN messages defined in the list.
Filters Mask: it is possible to define specific bits of the
COB-IDs that must have a specific values and others
that can change.
If the “Filters CobID” is set, the fields below have this
meaning:
In the field “
Filters Type
” the type of filter used is
defined. If “Positive” is set, the DataLogger will log the
COB-IDs listed, if “Negative” the DataLogger will
discharge the COB-IDs listed;
In the field “
Insert CobID
” the COB-ID to add to the
list is defined. It is possible to Add and Delete the COB-
IDs by clicking in the buttons “Add”, “Delete” or
“Delete All”.
Figure 10c: “Configuration Settings->CAN Filters (29bit)” window