If the USB version is used, in order to load the parameters or update the firmware in the device, follow these instructions:
Turn OFF the Device;
Connect the USB cable from your PC to the device;
Put Dip1 of ‘Dip-Switch A’ in ON position;
Select the “
COM port
” and press the “
Open Port
”
button;
Turn ON the device;
Check the “Device state” Led. It must blink quickly (see
“LEDS” section);
Select which operations you want to do;
Press the “
Update Device
” button;
When all the operations are “OK” turn OFF the device;
Press the “
Close Port
” button;
Put Dip1 of ‘Dip-Switch A’ in OFF position;
Turn ON the device.
Figure 6b: “Update Device” window (USB version)