10 TECHNICAL SPECIFICATION
ADEY reserve the right to amend the specification without notice .
10 .11
Noise: The equivalent continuous A-weighted sound pressure level at a
distance of 1 metre from the pump does not exceed 70 dB(A) .
11 TROUBLE SHOOTING GUIDE
Symptoms
Error Code
Probable Cause
Recommended Action
No power
Blank screen
No power to APU
Internal re-settable
fuse tripped
Check power supply/fuse
Disconnect APU from mains power for 20 seconds & and then re-connect
Pump(s) not
starting
No power to APU
Ensure the green light is on the front of the APU, check fuse .
Low water
Low water in tank
Depress float valve to varify water is filling tank, check water level and
supply .
System pressure =
set pressure
APU functioning correctly . Check the set system pressure .
Pump run fail
Pump seized
Force the pumps to run using the pump test function . Clear error .
Pump run fail
System pressure set
too high
System set pressure is set higher than the pump performance capability,
reduce set pressure . Ensure you have purchased the correct APU for the
system pressure required .
Sensor error
Pressure sensor fault
Remove pressure from the APU outlet and verify the displayed pressure
is 0 bar . Error will be displayed if the sensor signal is outside parameters .
(Replace sensor – call ADEY Customer Services) .
Pump(s) will not
stop
Sensor error
System pressure set
too high
System set pressure is set higher than the pump performance capability,
reduce set pressure . Ensure you have purchased the correct APU for the
system pressure required .
Pressure sensor fault
Remove pressure from the APU outlet and verify the displayed pressure
is 0 bar . Error will be displayed if the sensor signal is outside parameters .
(Replace sensor – call ADEY Customer Services) .
Low pressure alarm
triggered
Low pressure
Leak in system .
Check system for leaks . Check pump activity in logs . Check for leaking
pressure relief valve .
Low pressure alarm
set too high .
Reduce Low press alarm pressure . Check system pressure range during
normal operation .
Sensor error
Pressure sensor fault
Remove pressure from the APU outlet and verify the displayed pressure
is 0 bar . Error will be displayed if the sensor signal is outside parameters .
(Replace sensor – call ADEY Customer Services) .
High pressure
alarm triggered
High pressure
System pressure
too high
Check system operation . Increase High presure alarm set pressure .
Sensor error
Pressure sensor fault
Remove pressure from the APU outlet and verify the displayed pressure
is 0 bar . Error will be displayed if the sensor signal is outside parameters .
(Replace sensor – call ADEY Customer Services) .
Pump run time
alarm activated .
Pump running for
longer than set
time
Pump run time
alarm
Pump filling system
Activate system fill option to suppress alarm for 24 hours .
Leak in system
Check system for leakage . Monitor using system fill volume log, reset if
needed .
Increase pump run time limit .
Activity high alarm
activated . Pump
starting more than
set value
Activity High
alarm
Pump filling system
Activate system fill option to suppress alarm for 24 hours .
Leak in system
Check system for leakage . Monitor using system fill volume log, reset if
needed .
Activity High alarm
number too low
Increase the Activity High alarm value .
Sensor failure error Sensor error
Pressure sensor
outside specifcation
Remove pressure from the APU outlet and varify the displayed pressure
is 0 bar . Error will be displayed if the sensor signal is outside parameters .
(Replace sensor – call ADEY Customer Services) .
Low water error
Low water
Loss of water supply
to APU
Depress float valve to verify water is filling tank and check water level and
supply .
Water level set
too low
Adjust water level by turning float, ensure upper level probe is in contact
with water when the fill valve is turned off .
Check water level prior to leaving unattended .
Water overflowing
warning pipe or
weir
Water level too high
Check function of the fill valve, replace or adjust if needed .
Pump NRV leaking
Isolate APU from system and mains water and replace non-return valve
and holder .
Midi 135
CP1-03-04913
Midi 150
CP1-03-04914
Midi 235
CP1-03-04915
Midi 250
CP1-03-04916
General
Guarantee
2 year
Approvals
CE
Features
System capacity
Up to 300,000 litres
Mounting
Wall or floor mount
Pump control system
✓
✓
✓
✓
Intelligent control interface
✓
✓
✓
✓
System fill mode
✓
✓
✓
✓
Dry run protection
✓
✓
✓
✓
Typical Noise
60 dB(A)
60 dB(A)
62 dB(A)
62 dB(A)
Materials
Break tank
Polyethylene
Front cover
Acrylic capped ABS
Performance
Maximum Fill Pressure
3 .5 bar (350 kPa)
4 .1 bar (410 kPa)
Maximum flow
17 l/min
20 l/min
Maximum inlet pressure (tank fill valve)
7 bar (700 kPa)
Maximum working pressure
6 bar
Ambient air temperature
Min 4
o
C / Max 40
o
C
Relative humidity
95 % non-condensing
Min ./Max . water temperature
Min 4
o
C / Max 23
o
C
Water tank
Usable water capacity
8 litres
Inlet valve and fill rate
Torbeck (side entry) 12 l/min
Fluid category
CAT 5 (type AB air gap with weir)
Connections
Cold water inlet and outlet
15 mm compression x 600 mm flexible hose
Overflow (compression fitting)
G ¾ (19 - 23 mm diameter pipe)
Pump
Number of pumps
1
2
1
2
Pump mode
Duty
Duty-standby
Duty
Duty-standby
Pump type / head / impeller
Peripheral / brass / brass
Motor type
Induction (thermal trip, auto reset)
Duty rating
Continuous (S1)
Electrical
Power supply (Vac/Ph/Hz)
230/1/50
Power consumption - P1
380 Watts
545 Watts
Current (full load)
1 .7 Amps
2 .4 Amps
Fuse rating
5 Amps
Power cable length
1 .5 metres (pre-wired)
Alarm output
Multiple
Physical
Enclosure protection
IPX4
Width
415 mm
Depth
270 mm
Height
504 mm
Weight (including fittings)
13 .4 Kg
19 .4 Kg
13 .4 Kg
19 .4 Kg
Weight (Filled)
23 .4 Kg
29 .4 Kg
23 .4 Kg
29 .4 Kg