Adey CP1-03-04913 Installation And Servicing Download Page 15

28 

-

-

 29

 -

10  TECHNICAL SPECIFICATION

ADEY reserve the right to amend the specification without notice .

10 .11 

Noise:  The equivalent continuous A-weighted sound pressure level at a  

 

 

distance of 1 metre from the pump does not exceed 70 dB(A) .

11  TROUBLE SHOOTING GUIDE

Symptoms

Error Code

Probable Cause

Recommended Action

No power

Blank screen

No power to APU

Internal re-settable 

fuse tripped

Check power supply/fuse

Disconnect APU from mains power for 20 seconds & and then re-connect

Pump(s) not 

starting

No power to APU

Ensure the green light is on the front of the APU, check fuse .

Low water

Low water in tank

Depress float valve to varify water is filling tank, check water level and 

supply .

System pressure = 

set pressure

APU functioning correctly . Check the set system pressure .

Pump run fail

Pump seized

Force the pumps to run using the pump test function . Clear error .

Pump run fail

System pressure set 

too high

System set pressure is set higher than the pump performance capability, 

reduce set pressure . Ensure you have purchased the correct APU for the 

system pressure required .

Sensor error

Pressure sensor fault

Remove pressure from the APU outlet and verify the displayed pressure 

is 0 bar . Error will be displayed if the sensor signal is outside parameters . 

(Replace sensor – call ADEY Customer Services) .

Pump(s) will not 

stop

Sensor error

System pressure set 

too high

System set pressure is set higher than the pump performance capability, 

reduce set pressure . Ensure you have purchased the correct APU for the 

system pressure required .

Pressure sensor fault

Remove pressure from the APU outlet and verify the displayed pressure 

is 0 bar . Error will be displayed if the sensor signal is outside parameters . 

(Replace sensor – call ADEY Customer Services) .

Low pressure alarm 

triggered

Low pressure

Leak in system .

Check system for leaks . Check pump activity in logs . Check for leaking 

pressure relief valve .

Low pressure alarm 

set too high .

Reduce Low press alarm pressure . Check system pressure range during 

normal operation .

Sensor error

Pressure sensor fault

Remove pressure from the APU outlet and verify the displayed pressure 

is 0 bar . Error will be displayed if the sensor signal is outside parameters . 

(Replace sensor – call ADEY Customer Services) .

High pressure 

alarm triggered

High pressure

System pressure 

too high

Check system operation . Increase High presure alarm set pressure .

Sensor error

Pressure sensor fault

Remove pressure from the APU outlet and verify the displayed pressure 

is 0 bar . Error will be displayed if the sensor signal is outside parameters . 

(Replace sensor – call ADEY Customer Services) .

Pump run time 

alarm activated . 

Pump running for 

longer than set 

time

Pump run time 

alarm

Pump filling system

Activate system fill option to suppress alarm for 24 hours .

Leak in system

Check system for leakage . Monitor using system fill volume log, reset if 

needed .

Increase pump run time limit .

Activity high alarm 

activated . Pump 

starting more than 

set value

Activity High 

alarm

Pump filling system

Activate system fill option to suppress alarm for 24 hours .

Leak in system

Check system for leakage . Monitor using system fill volume log, reset if 

needed .

Activity High alarm 

number too low

Increase the Activity High alarm value .

Sensor failure error Sensor error

Pressure sensor 

outside specifcation

Remove pressure from the APU outlet and varify the displayed pressure 

is 0 bar . Error will be displayed if the sensor signal is outside parameters . 

(Replace sensor – call ADEY Customer Services) .

Low water error

Low water

Loss of water supply 

to APU

Depress float valve to verify water is filling tank and check water level and 

supply .

Water level set 

too low

Adjust water level by turning float, ensure upper level probe is in contact 

with water when the fill valve is turned off .

Check water level prior to leaving unattended .

Water overflowing 

warning pipe or 

weir

Water level too high

Check function of the fill valve, replace or adjust if needed .

Pump NRV leaking

Isolate APU from system and mains water and replace non-return valve 

and holder .

Midi 135

CP1-03-04913

Midi 150

CP1-03-04914

Midi 235

CP1-03-04915

Midi 250

CP1-03-04916

General

Guarantee

2 year

Approvals

CE

Features

System capacity

Up to 300,000 litres

Mounting

Wall or floor mount

Pump control system

Intelligent control interface

System fill mode

Dry run protection

Typical Noise

60 dB(A)

60 dB(A)

62 dB(A)

62 dB(A)

Materials

Break tank

Polyethylene

Front cover

Acrylic capped ABS

Performance

Maximum Fill Pressure

3 .5 bar (350 kPa)

4 .1 bar (410 kPa)

Maximum flow

17 l/min

20 l/min

Maximum inlet pressure (tank fill valve)

7 bar (700 kPa)

Maximum working pressure

6 bar

Ambient air temperature

Min 4 

o

C / Max 40 

o

C

Relative humidity

95 % non-condensing

Min ./Max . water temperature

Min 4 

o

C / Max 23 

o

C

Water tank

Usable water capacity

8 litres

Inlet valve and fill rate

Torbeck (side entry)   12 l/min

Fluid category

CAT 5 (type AB air gap with weir)

Connections

Cold water inlet and outlet

15 mm compression x 600 mm flexible hose

Overflow (compression fitting)

G ¾ (19 - 23 mm diameter pipe)

Pump

Number of pumps

1

2

1

2

Pump mode

Duty

Duty-standby

Duty

Duty-standby

Pump type / head / impeller

Peripheral / brass / brass

Motor type

Induction (thermal trip, auto reset)

Duty rating

Continuous (S1)

Electrical

Power supply (Vac/Ph/Hz)

230/1/50

Power consumption - P1

380 Watts

545 Watts

Current (full load)

1 .7 Amps

2 .4 Amps

Fuse rating

5 Amps

Power cable length

1 .5 metres (pre-wired)

Alarm output

Multiple

Physical

Enclosure protection

IPX4

Width

415 mm

Depth

270 mm

Height

504 mm

Weight (including fittings)

13 .4 Kg

19 .4 Kg

13 .4 Kg

19 .4 Kg

Weight (Filled)

23 .4 Kg

29 .4 Kg

23 .4 Kg

29 .4 Kg

Summary of Contents for CP1-03-04913

Page 1: ...Installation and servicing Midi 135 150 235 250 Digital Pressurisation Unit...

Page 2: ...rated with the front cover in place z In the interests of electrical safety a 30 mA residual current device R C D not supplied should be installed in the supply circuit This may be part of a consumer...

Page 3: ...l cause leakage 1 16 Secure pipework Ensure pipework to and from pump is independently supported clipped to prevent forces being transferred to inlet and outlet branches of the unit Do not secure pipe...

Page 4: ...ny spillage is contained or routed to avoid electrics or areas sensitive to water damage As part of the AB airgap CAT 5 fluid isolation the APU has a weir type overflow on the right hand side water wi...

Page 5: ...nit on either the left or right The pumps are connected to the tank via a rubber connector A pressure transducer monitors system pressure and if a reduction in system pressure is detected the controll...

Page 6: ...which the APU Midi is located is flat and level 3 If possible locate the unit against a wall for added stability 4 If the APU Midi is located in an area that might be subjected to flooding mount the A...

Page 7: ...dance with the current national electrical regulations and installed by a qualified person 5 12 Safety In the interests of electrical safety a 30 mA residual current device R C D not supplied should b...

Page 8: ...for boiler chiller shut down in the event that the APU Midi detects system pressure above the Hi alarm pressure or below the Lo alarm pressure The boiler interlock contact will be open circuit below t...

Page 9: ...to function correctly the following conditions must be met If these conditions have not been met the commissioning process should not continue z Ensure the system connection has been made into the hea...

Page 10: ...ctivity Pump run time Alarm reset 6 18 Setting menu Pass code protected if set The following functions can be set and modified System pressure 2 see Fig 20 Sets the required system pressure Set in 0 1...

Page 11: ...able from 3 to 120 seconds pre set to 3 seconds Increasing this time will reduce un wanted APU Midi operation during rapid system pressure fluctuations circulator pump starts Pump test Forces pump 1 L...

Page 12: ...pressure error and the red error light will illuminate on the front of the APU this is normal z Open the isolation valve on the outlet of the APU and the APU will run and start to fill the system 6 2...

Page 13: ...on the screen may be shown slightly higher than the set pressure whilst the pump is running As soon as the pump stops this displayed reading will settle back to the actual system pressure During the n...

Page 14: ...ng order after a prolonged period of maintainance the following steps should be taken 1 Inspect the APU for signs of damage 2 Check APU tank for debris remove debris and clean tank if needed Debris ma...

Page 15: ...em Activate system fill option to suppress alarm for 24 hours Leak in system Check system for leakage Monitor using system fill volume log reset if needed Increase pump run time limit Activity high al...

Page 16: ...pump operation Float valve operation x Level probe operation x Water condition x Exp vessel pre charge x Comments Service No 2 Date Engineer name Company name Tel No System pressure bar Differential...

Page 17: ...Office Gloucester Road Cheltenham GL51 8NR United Kingdom Object of the declaration Pressurisation Unit The object of the declaration described above is in conformity with the relevant Union harmonisa...

Page 18: ...34...

Page 19: ...com www adey com Produced from recycled material A carbon neutral company All ADEY marks are trademarks of Adey Holdings 2008 Limited Please visit adey com trademarks for a list of ADEY marks Copyrigh...