EN
sigfox TEMP- Guide utilisateur / User guide version V2.0.1
70
Page
of 84
FR
• Byte 5:
o Bits 0 to 3:
0: deactivated
1: activated
o Bits 4 to 7: The user identifier defined in register 322
• Bytes 6 to 7: Value measured on the probe 2
• Signed value on 16 bits,
• Expressed in tenths of degrees,
• Most Significant Byte first
• The special value 0x8000, equivalent to -3276,8°C is returned in the event of a fault in the sensor.
In the example in grey this gives:
• Byte 2=0xD1:
o Bits 0 to 3 = 0x1: The probe 1 is activated
o Bits 4 to 7 = 0xD: the identifier of the probe 1 defined by the user is equal to 0xD
• Bytes 3 to 4=0x015E: The value measured on the probe 1 is 350/10=35°C
• Byte 5=0x81:
o Bits 0 to 3 = 0x1: The probe 2 is activated
o Bits 4 to 7 = 0x8: the identifier of the probe 1 defined by the user is equal to 0x8
• Bytes 6 to 7=0xFF06: the hexadecimal value 0xFF06 = -250. Hence the value measured on the probe 2 is -250/10=-25°C
4.1.7 Summary of the conditions of the transmission of the uplink frames
The table below summarizes the conditions of the transmission of the different uplink frames:
Code
Description
Sending conditions
0x10
0x11
0x12
Frames of information on the product configuration
• Product start-up
• Exit from the configuration mode (AT Command)
0x20 Frames of information on the network configuration
• Product start-up
• Exit from the configuration mode (AT Command)
0x30 Keep Alive frame
• Periodically in the «event” mode
0x31 Reply frame to a register value request in a downlink frame
• Reception of a downlink frame 0x40
0x43 Data Frame
• Product start-up
• Passing a threshold (event mode)
• End of period (periodic mode)
Summary of Contents for ARF8181BA2D
Page 5: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 5 Page of 84 FR FRANCAIS...
Page 7: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 7 Page of 84 FR...
Page 43: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 43 Page of 84 FR ENGLISH...
Page 45: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 45 Page of 84 FR...