3.3. AT commands
A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com-
mands available on the product).
Each command must finish with a “CR” or “CR” “LF” – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the product will feedback:
<cr><lf> “Data” for ATS type playback control <n> ?, AT/S or AT/V
“O” <cr><lf>, for any other command when this has been accepted.
“E” <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid parameter, etc.
“CM” <cr><lf>, if it accepts the input in command mode
Table of AT commands:
Command
Description
Reply example
+++
Input request in command mode
CONNECTING... <cr><lf>
CM<cr><lf>
ATPIN <PIN>
Gives access to AT commands if register S304 is
different of 0
AT/V
Feeds back the version of the APPLICATIF and
RTU software
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_WM-
BUS_868_PRG_1601_V00.00.03
Or
APP_8181AAA_PRG1701_V01.00.02:RTU_8120AAB_
PRG_1701_V01.00.01
AT/N
Feeds back the type of network
"LoRa" or "SIGFOX" or « WMBUS »
ATS<n>?
Feeds back the content of the n range
Sn=y where y represents the content of the n range
AT/S
Edits the content of all of the user ranges in the
form of a list.
/
ATS<n>=<m>
Transfers the m VALUE to the n range
«O»<cr><lf> if Ok, «E»<cr><lf> if error, «W»<cr><lf> if
coherency error
AT&W
Saves the current configuration to non-volatile
memory.
«O»<cr><lf>, «E»<cr><lf> if coherency error
ATO
Exit command mode
«O»<cr><lf>, «E»<cr><lf> if coherency error
ATT63 PROVIDER
Unblock the operating range
«O»<cr><lf>
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
Description
Response Syntax to Next Line
+++
Input request in command mode
CONNECTING...
CM
ATS202=1
Changing the number of repetitions
E -> This command is not validated (register no un-
locked)
ATT63 PROVIDER
Unblock the operating range
O
ATS202=1
Changing the number of repetitions
O
ATS202?
Feeds back the value of the S202 range
S202=1
AT&W
Memory request for the state range
O
ATO
Output request in command mode
O
Interpreting the previous example: the user wanted to modify the number of repetition after having made an unauthorized command (answer
E), and the ranges were unblocked in order to modify the range. The range S202 was verified and the parameters were saved before exiting.
When exiting command mode, the device will start a new cycle of emission.
Summary of Contents for ARF8181BA2D
Page 5: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 5 Page of 84 FR FRANCAIS...
Page 7: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 7 Page of 84 FR...
Page 43: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 43 Page of 84 FR ENGLISH...
Page 45: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 45 Page of 84 FR...