Identifier of the probe 1
Hexadecimal Default: 0x00
Bits 0 to 3: Reserved
Bits 4 to 7: Identifier (free to use)
S321
1
Configuring the event behavior of the
probe 1
Hexadecimal Default 0x03
Bits 0 to 1: Threshold triggering
• 0 = None
• 1 = Low only
• 2 = High only
• 3 = Low and High
Bits 2 to 7: Reserved
S322
1
Identifier of the probe 2
Hexadecimal See details of register 320
S323
1
Configuring the event behavior of the
probe 2
Hexadecimal See details of register 321
S324
4
High threshold value of the probe 1
Decimal
Default: 300
Min/max: -550 to 1200 (signed value)
Units: tenth of °C
S325
1
Value of the high threshold hysteresis
of the probe 1:
Decimal
Default: 10
Min/max: 0 of 255 (Unsigned value)
Unit: tenth of °C
S326
4
Low threshold value of the probe 1
Decimal
Default: 50
Min/max: -550 to 1200 (Unsigned value)
Unit: tenth of °C
S327
1
Value of the low threshold hysteresis of
the probe 1
Decimal
Default: 10
Min/max: 0 to 255 (Unsigned value)
Unit: tenth of °C
S328
4
High threshold value of the probe 2
Decimal
Default: 300
Min/max: -550 to 1200 (Unsigned value)
Unit: tenth of °C
S329
1
Value of the high threshold hysteresis
of the probe 2:
Decimal
Default: 10
Min/max: 0 to 255 (Unsigned value)
Unit: tenth of °C
S330
4
Low threshold value of the probe 2
Decimal
Default: 50
Min/max: -550 to 1200 (Unsigned value)
Unit: tenth of °C
S331
1
Value of the low threshold hysteresis of
the probe 2
Decimal
Default: 10
Min/max: 0 to 255 (Unsigned value)
Unit: tenth of °C
S332
1
Acquisition period
Decimal
Default: 10
Min/max : 1 to 255
Unit:
x 1minute if S306=1
x 10 seconds if S306=2
S333
1
Super-sampling factor
Decimal
Default: 1
Min/max: 1 to 10
Unit: /
S340
1
Activation and deactivation of the
probes
Decimal
Default : 3
1 : only probe 1 activated
2 : only probe 2 activated
3 : both probes are activated
CAUTION: If S340 = 1 or 2, if the remaining probe is torn off, cut off or disconnected the product will stop transmitting
Summary of Contents for ARF8181BA2D
Page 5: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 5 Page of 84 FR FRANCAIS...
Page 7: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 7 Page of 84 FR...
Page 43: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 43 Page of 84 FR ENGLISH...
Page 45: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 45 Page of 84 FR...