EN
LoRaWAN TEMP - Guide utilisateur / User guide version V2.0.1
63 of 86
3.4. Description of the registers
On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration
has not been changed). Command Modification TTY<n>=<M> allows you to change the content of the registers: <n> representing the number
of the register and <m> the value to be assigned. This latter is either a decimal value or a hexadecimal value consistent with the «encoding»
column of the tables below.
Examples:
• ATS300=6 assigns the decimal value 6 in register 300
• ATS320=2 assigns the hexadecimal value 0x02 in register 320
It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.
IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in the paragraphs that follow are
reserved and must not be changed.
3.4.1 Function registers
The list of registers below allows you to change the behavior of the product application.
Register
Size
(bytes)
Description
Coding
Details
S300
1
Transmission period of the Keep Alive
frame
Decimal
Default: 144
Min/max: 1 to 255
Unit:
x 10min if S306=1
x 20s if S306=2
S301
1
Transmission period of data sensors
Decimal
Default: 6
Min/max: 0 à 255
Unit:
x 10min if S306=1
x 20s if S306=2
The value 0 means no periodic sending, therefore event
operation
S303
1
Confirmed mode activation
Decimal
Default : 0 (deactivated)
Values : 0 (deactivated) to 1 (activated)
S304
2
PIN code
Decimal
Default : 0 (disabled)
Min/max : 0 to 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
IMPORTANT: The product does not have a mechanism
to unlock the PIN code if it is activated and the code is
forgotten.
S306
1
Global operation
Decimal
Default: 0
Allows the product to be switched into one of the follow-
ing modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
• 3: REPLI mode
S320
1
Identifier of the probe 1
Hexadecimal Default: 0x00
Bits 0 to 3: Reserved
Bits 4 to 7: Identifier (free to use)
Summary of Contents for ARF8180AA
Page 2: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 2 of 86 ...
Page 5: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 5 of 86 FRANCAIS ...
Page 7: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 7 of 86 ...
Page 8: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 8 of 86 ...
Page 9: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 9 of 86 ...
Page 10: ...FR LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 10 of 86 ...
Page 43: ...ENGLISH ...
Page 45: ...EN LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 45 of 86 ...
Page 46: ...EN LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 46 of 86 ...
Page 47: ...EN LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 47 of 86 ...
Page 48: ...EN LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 48 of 86 ...
Page 82: ...DE LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 82 of 86 DEUTSCH Vorschriften ...
Page 83: ...DE LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 83 of 86 ...
Page 84: ...DE LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 84 of 86 ...
Page 85: ...DE LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 85 of 86 ...
Page 86: ...DE LoRaWAN TEMP Guide utilisateur User guide version V2 0 1 86 of 86 ...