Adesys SVL Series Manual Download Page 9

Page 9

Manual SVL 4G Weblogger 

Adesys B.V. | Wateringen

3.6.4  Factory reset

By performing a factory reset all settings will be lost and a reset to the default settings will be prompted.

Notification procedure

The notification procedure starts in the event of a status change or error. If set up, the SVL will first 

establish a data connection and send data, and then send the associated notification message to the first 

contact on the call list that has been set up.

4.1  Notification message

An SMS or e-mail alarm message is structured as follows: 

Device name | input name | status

.

•  Device name

: contains a text chosen by the user. This can be set up in the system menu.

•  Input name

: contains a text chosen by the user, which is coupled to the input channel. This can be set 

up in the I/O menu for the relevant input.

System errors such as the Ethernet error and the ‘no numbers coupled’ error have a fixed text (in English) 

that cannot be changed. For example, powerfailure is used for a mains power failure.

• 

Status:

 shows whether an input channel is Active or Idle. Active and recovery texts can be set up in the 

system menu.

E-mail

 

This is used if an E-mail address is entered in the call list. In the event of a notification, the dialer first 

sends a message to Checkmyproces via httpost, whereupon Checkmyproces converts the notification 

into an E-mail message and sends this to the E-mail address that has been entered. The structure of the 

message is the same as the SMS.

4.2  Notification of status changes

After input channel 1 has been activated, the following can be observed:

• 

The green LED (

on/busy

) flashes 1x to indicate that input channel 1 is active;

• 

After a few seconds, the green LED (

on/busy

) flashes faster to indicate that the SMS message is being 

sent;

• 

The green LED (

on/busy

) again flashes 1x. The SMS message has been sent;

• 

The notification message appears on the mobile phone to which the SMS message has been sent; this 

message can be structured as follows: 

LOCATION PUMP FAULT Active;

• 

The green LED (on/busy) continues to show the status of the input until this ceases to be active;

• 

If the input returns to idle mode and a recovery report has been set up, the notification message will be 

structured as follows: 

LOCATION PUMP FAULT Idle.

4.3  Notification of mains power failure

The SVL is equipped with a supercap. This gives the dialer the option of sending a few messages in the 

event of a power failure. The associated notification message is sent to the first number in the call list 

linked to the mains power failure. After the power fails, the following can be observed:

• 

The red LED (

error

) flashes 5x to indicate that the supply voltage has been lost;

• 

After a few seconds, the green LED (

on/busy

) flashes faster to indicate that the SMS message is being 

sent;

• 

The green LED (

on/busy

) remains on. The SMS message has been sent;

• 

The notification appears on the mobile phone to which the SMS message has been sent; this message 

can be structured as follows: 

LOCATION powerfailure Active

;

• 

The red LED (

error

) continues to show the status of the mains power failure until this has been 

recovered.

A mains power failure message always takes priority over an ongoing notification of a status change. After 

notification of the mains power failure, any interrupted notification can be restarted. Notification of status 

changes that have not yet been notified then continues. This priority arrangement applies for both 

Active

 

and 

Idle

.

Figure 2 Notification  prodecure

Summary of Contents for SVL Series

Page 1: ...MEASURING ALERTING CONNECTING EN Manual SVL Version 06 2019...

Page 2: ...2 7 Ethernet 6 2 8 2G 4G connection 6 2 9 Inputs and outputs 7 3 SV prog 7 3 1 Installation 7 3 2 Status screen 7 3 3 Call list 7 3 4 I O 7 3 4 1 Input delay 7 3 4 2 Recovery report idle 8 3 4 3 Syst...

Page 3: ...oltage protection device To reduce the probability of damage to the equipment the SVL should be placed in an environment protected against electrostatic discharge ESD The SVL is intended for use as a...

Page 4: ...ge You should therefore discuss the remaining risk with your insurer 1 8 Identification 1 Reset button 2 LED status indicator general status on busy antenna level network error message error 3 Antenna...

Page 5: ...re connection Put the SVL onto the DIN rail at an angle 1 It is important that the SVL s DIN rail clip is positioned on the top of the DIN rail Tilt the SVL to clip it into place 2 Then check whether...

Page 6: ...solation and the SVL is connected to the same power supply there is a real chance of earth loops and or short circuits in this power supply 2 6 Reset key The reset key has three functions first of all...

Page 7: ...VL has been switched on the tool will display this in the overview after a few seconds and the SVL can be configured by clicking it When search dialers is pressed SV prog shows all accessible dialers...

Page 8: ...lowing exceptions Data connection URL http svx meetcentrale nl 80 severa Protocol http Port 80 System settings URL mqtt meetcentrale nl Protocol mqtt Port 1883 3 5 2 Own server It is also possible to...

Page 9: ...put channel 1 is active After a few seconds the green LED on busy flashes faster to indicate that the SMS message is being sent The green LED on busy again flashes 1x The SMS message has been sent The...

Page 10: ...parameter1 parameter2 Command O Output Parameter1 A Active of I Idle of P Puls schakelen default 2 seconden active Parameter2 Ingangsnummer Note The output number is not the same as the relay number...

Page 11: ...80 5x Antenna level 81 100 Faster Establishing connection clientmode Number of flashes for on busy green Off SVA is switched off On SVA is switched on Faster Starting up sending message 1x Input 1 ac...

Page 12: ...tage Contact or Digital Input mode Open Collector OC outputs Switchable voltage level Imax per output Outputs are protected against overload Detection disconnection mechanism per 4 outputs arranged Sh...

Page 13: ...res above 2000 metres the maximum operating temperature is reduced by 1 5 C per 300 metres up to a maximum heigth of 4000 metres Regulations EMC Emission EN 301 489 01 V1 9 2 EN 301 489 03 V1 4 1 Clas...

Page 14: ...so available in this SV product line SVA 4G alarm dialler SVM 4G modem Checkmyprocess com Industrial 4G SMS E mail alarm dialler for monitoring of your technical processes Industrial 4G modem sms alar...