Adesys SVL Series Manual Download Page 12

Page 12

Manual SVL 4G Weblogger 

Adesys B.V. | Wateringen

Hardware

4201 4G

Type I/O

SVL0040-I

SVL0022-I

SVL0400-I

SVL0402-I

SVL0420-I

SVL0800-I

Contact inputs

max. contactresistance

max. Vinl

ow

0 - 8

1kΩ

1V

Pulse counter

Filter (pulse duration Tmin)

•  fast

•  average

•  slow

max. contactresistance @ active

max. Vin

low

Pulse levels

•  Vmin

high

• 

Vmax

low

• 

Vmax

level

0 - 8

1.2–20 ms

20–100 ms

> 100 ms

1kΩ

1V

 2V

1.5V

30V

Digital inputs 

(5-24V DC)

Abs. Vmax level

Vnom

max

Vmin

high

Vmax

low

4 - 8

30V

24V

2.0V

1.5V

Analogue inputs (0–10V DC)

Range

Abs. Vmax level

Vmax

nom

4 - 8

0-10V DC

30V

24V

Current input 

(0–20mA)

Range

Input power limited 

(in case up to max. 30V at input during current mode)

4 - 8

4 ... 20mA

approx. 240mA

for 10ms, then 500ms out

PT100 input (80–157Ω)

•  2 wire

•  wire

Range

Vin

max

4

2

-50 ... 150ºC

30V

Inputs are protected against 24VAC. However, they are not suitable for measuring / detecting AC signals in 

Voltage / Contact or Digital Input mode.

Open Collector (OC) outputs

Switchable voltage level

Imax per output

Outputs are protected against overload. Detection / 

disconnection mechanism per 4 outputs arranged:

Short-circuit current

4

SELV

45mA

 

1 - 4

5 - 8

< 600mA

 during <500us

Relay output

Relay modes (P/NO/NC)

Imax per output

Switchable voltage level

Life expectancy

0 - 2

1A

SELV 30 VDC/1A (resistive) 

1 x 10

5

 operations at 20°C, 1 Hz

Ethernet

Type

10Base-T/ 100Base-TX

Auto MDIX

Yes

GSM/GPRS/UMTS/ 

LTE Cat-M1

Mobiel netwerk

Global-Band FDD-LTE 

B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B26/

B28/B39 (B39 CAT-M1 only)

GSM/GPRS/EDGE 850/900/1800/1900 MHz (Quadband)

Antenneaansluiting Connector type SMA female

Power supply

Nominal

1-2 Watt (2W whilst the supercap is charging)

Peak

8.5 Watt / 18 VA (AC)

Imax

0.75A @ Vin= 11.4 V

Power supply range

11.4 ... 46 V DC (SELV)

20 ... 35 V AC (SELV)

Built-in emergency 

power supply

Supercap (loaded after a few minutes) so that a power 

failure can still be reported

Expected service life (Calculated MTBF)

88167 hours (=10 years), according to componentcounting 

method

Summary of Contents for SVL Series

Page 1: ...MEASURING ALERTING CONNECTING EN Manual SVL Version 06 2019...

Page 2: ...2 7 Ethernet 6 2 8 2G 4G connection 6 2 9 Inputs and outputs 7 3 SV prog 7 3 1 Installation 7 3 2 Status screen 7 3 3 Call list 7 3 4 I O 7 3 4 1 Input delay 7 3 4 2 Recovery report idle 8 3 4 3 Syst...

Page 3: ...oltage protection device To reduce the probability of damage to the equipment the SVL should be placed in an environment protected against electrostatic discharge ESD The SVL is intended for use as a...

Page 4: ...ge You should therefore discuss the remaining risk with your insurer 1 8 Identification 1 Reset button 2 LED status indicator general status on busy antenna level network error message error 3 Antenna...

Page 5: ...re connection Put the SVL onto the DIN rail at an angle 1 It is important that the SVL s DIN rail clip is positioned on the top of the DIN rail Tilt the SVL to clip it into place 2 Then check whether...

Page 6: ...solation and the SVL is connected to the same power supply there is a real chance of earth loops and or short circuits in this power supply 2 6 Reset key The reset key has three functions first of all...

Page 7: ...VL has been switched on the tool will display this in the overview after a few seconds and the SVL can be configured by clicking it When search dialers is pressed SV prog shows all accessible dialers...

Page 8: ...lowing exceptions Data connection URL http svx meetcentrale nl 80 severa Protocol http Port 80 System settings URL mqtt meetcentrale nl Protocol mqtt Port 1883 3 5 2 Own server It is also possible to...

Page 9: ...put channel 1 is active After a few seconds the green LED on busy flashes faster to indicate that the SMS message is being sent The green LED on busy again flashes 1x The SMS message has been sent The...

Page 10: ...parameter1 parameter2 Command O Output Parameter1 A Active of I Idle of P Puls schakelen default 2 seconden active Parameter2 Ingangsnummer Note The output number is not the same as the relay number...

Page 11: ...80 5x Antenna level 81 100 Faster Establishing connection clientmode Number of flashes for on busy green Off SVA is switched off On SVA is switched on Faster Starting up sending message 1x Input 1 ac...

Page 12: ...tage Contact or Digital Input mode Open Collector OC outputs Switchable voltage level Imax per output Outputs are protected against overload Detection disconnection mechanism per 4 outputs arranged Sh...

Page 13: ...res above 2000 metres the maximum operating temperature is reduced by 1 5 C per 300 metres up to a maximum heigth of 4000 metres Regulations EMC Emission EN 301 489 01 V1 9 2 EN 301 489 03 V1 4 1 Clas...

Page 14: ...so available in this SV product line SVA 4G alarm dialler SVM 4G modem Checkmyprocess com Industrial 4G SMS E mail alarm dialler for monitoring of your technical processes Industrial 4G modem sms alar...

Reviews: