Programming Fields
Entry/Exit
Ö
/# 09 Entry Time
Multiples of 10 Seconds
i.e. 01=10 secs, 02=20secs etc.
Multiples of 10 Seconds
Ö
/# 10 Exit Delay
i.e. 01=10 secs, 02=20secs etc.
00 = Final Contact Set
Ö
/# 17 Supplementary Entry
0 = NO
Delay
1= YES
Ö
/# 18 Entry Deviation Permitted
0 = NO
1 = YES
Ö
/# 29 Easy Set
0 = NO
1 = YES - use ‘#’ instead of code
0 = Normal Zone 7 Use.
Ö
/# 11 Setting Options
1 = Keyswitch Set / Unset.
4 = Exit Terminate AWAY set.
5 = Exit Terminate all set modes
(audible exit tone in Stay).
6 = Normal Zone Use. Exit Termi-
nate connected between Data In and
Data Out on keypad bus.
Output Options
Ö
/# 12 Bell Delay
0 = Instant Bells
1 = 10 minute bell delay
Ö
/# 13 Bell Duration
Multiples of 2 Minutes
i.e. 01 = 2 mins, 10 = 20 mins
Ö
/# 14 SW- (Switched -ve
0 = Internal Sounder
Terminal) Internal Sounder
1 = Power Reset
or Power Reset
Area 1
(10)
(0)
(0)
If set to 1 the SW- terminal can be used as the negative supply for a latching
detector. For this setting, the 4110SM loudspeaker module must not be fitted.
Area 1
(0 3)
Area 1
(0 3)
Area 1
(0)
Area 1
(0)
Area 1
(1)
Area 1
(0)
After the bell duration expires the system will rearm and lockout
the alarm zone. The maximum possible number of rearms is four.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA 10
Page 2: ...2 www PDF Zoo com firealarmresources com...
Page 15: ...15 Figure 2 2 Telephone Line Connections www PDF Zoo com firealarmresources com...
Page 16: ...16 www PDF Zoo com firealarmresources com...
Page 26: ...26 www PDF Zoo com firealarmresources com...
Page 27: ...27 www PDF Zoo com firealarmresources com...
Page 28: ...28 IE1 4110 ISSUE A 30 7 99 www PDF Zoo com firealarmresources com...