Rapid Eye Remote Video Unit Installation and Setup Guide
3.0 Installing the Remote Video Unit
17
Connect the indicated ALARM INPUTS and CONTROL OUTPUTS of
the Rapid Eye PLUS Remote Video Unit as follows:
Figure 8: Rapid Eye to RAS Panel Cable Connections
Alarm Inputs
1.
Attach alarm 16 input to the TRIP connection on the audio panel
terminal strip.
2.
Attach alarm input 16 ground to the first GND from the left
connection on the audio panel terminal strip.
Control Outputs
1.
Attach Output 7 to the DATA IN connection on the audio panel
terminal strip.
2.
Attach Output 8 to the CLK connection on the audio panel terminal
strip.
Attach the ground connection to the second from the left GND connection on
the audio panel terminal strip.