3 –
/<1;
DATA FIELDS
Field
Function
Programmed Values
[ ] = Table 1 Default Values
SYSTEM SETUP (
✱
20–
✱
30)
✱
20
INSTALLER CODE
[4112]
Enter 4 digits, 0–9
✱
21
QUICK ARM ENABLE
†
[1]
0 = no; 1 = yes
✱
22
KEYPAD BACKLIGHT TIMEOUT
[0]
0 = none (backlighting always on); 1 = backlight off after 10secs
✱
23
FORCED BYPASS
†
[0]
0 = none; 1 = bypass open zones
UL installations = 0
✱
24
RF HOUSE ID CODE
|
[00]
00 = disable all wireless keypad usage;
01–31 = 5827/5827BD/5804BD house ID
✱
25
POWERLINE CARRIER DEVICE
[0]
HOUSE CODE
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 =
J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P
✱
26
CHIME BY ZONE
† [1]
0 = no; 1 = yes (program zones to chime on zone list 3)
✱
27
REAL TIME CLOCK DISPLAY
† [1]
0 = no; 1 = yes, display time on keypad
✱
29
DAYLIGHT SAVING TIME
[4, 10]
START/END MONTH
Start
End
1-9, #+10,#+11,#+12. Enter 0,0 if no daylight savings time used.
✱
30
DAYLIGHT SAVING TIME
[1,5]
START/END WEEKEND
Start End
0 = disable; 1=first; 2=second; 3=third; 4=fourth;
5=last; 6=next to last; 7=third from last
ZONE SOUNDS AND TIMING (
✱
31–
✱
39)
✱
31
SINGLE ALARM SOUNDING/ZONE
† [0]
1 = yes, limit once per arming period; 0 = no limit;
UL installations = 0
✱
32
FIRE SOUNDER TIMEOUT
† [0]
0 = timeout; 1 = no timeout
✱
33
ALARM BELL TIMEOUT
† [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min;
UL installations = 1 (4 min) minimum
† Entry of a number other than one specified will give unpredictable results.