background image

– 

14 –

POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81.

Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.

80 OUTPUT DEVICES

Fill in the required data on the worksheet on below and follow the programming procedure in the Installation Instructions as
you enter the data during the displays and prompts that appear in sequence.

Note:    Field 

25 must be programmed with a House Code.

 

S T A R T

either or both

     

S T O P

         

either or both

DEVICE

NUMBER

ACTION

(aa)

EVENT

ZONE

TYPE

LIST

 (et)

(zl)

ZONE TYPE  
SYST OP'N
     (zt)

RESTORE

ZONE LIST

(zl)

ZONE TYPE    
/SYST OP'N

(zt)

P.L.C.D.

 

 

01

P.L.C.D.

  

02

P.L.C.D.

* 

 

 03

P.L.C.D.

*

 

  

04

P.L.C.D.

*

 

05

P.L.C.D

.*

 

    06

SYSTEM

07

P.L.C.D.

*

 

 

SYSTEM

08

P.L.C.D.

*

 

 

 

*

 

P.L.C.D. = Powerline Carrier Device (X-10).

Where:

A  = DEVICE ACTION

0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.

  ET

 

=  EVENT TYPE

0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.

Z L

  

=  ZONE LIST 1, 2, or 3 (from Field 

81) or 0 = Not Used.

 "START"  ZONE LIST:  Upon alarm, fault, or  trouble of ANY zone on this list, device action will START.
 "STOP" RESTORE  of  ZONE LIST:  Upon restore of ALL zones on this list, device action will STOP.  It

   need not be same list as used for START.

NOTE: Do not assign zones with zone types 20, 21, or 22 to a zone list.

ZT = ZONE TYPE/SYSTEM OPERATION  Choices for Zone Types are:

00 = Not Used

06 = 24 Hr Silent

01 = Entry/Exit#1 

07 = 24 Hr Audible

02 = Entry/Exit#2 

08 = 24 Hr Aux

03 = Perimeter 

09 = Fire Zone

04 = Interior Follower 

10 = Interior w/Delay

05 = Trouble Day/Alarm Night 

24= Silent Burglary

Note: Any zone in "ZT" going into alarm,

fault, or trouble will activate device.
Any zone of that type that restores
will stop device action.

Choices for System Operation are:

20 = Arming–Stay

38 = Chime 

21 = Arming–Away

39 = Any Fire Alarm

22 = Disarming (Code + OFF)

40 = Bypassing

31 = End of Exit Time

42 = System Battery Low

* Or at Disarming, whichever occurs

32 = Start of Entry Time

43 = Communication Failure

earlier.

33 = Any Burglary Alarm

52 = Kissoff

36 = *At Bell Timeout

58 = Duress

Note: In normal operation mode:
For Devices 1-6:

For Devices 7 and 8:

N = device (unit) number

Fu Lights On + N

Code + Fu 4 + N

(Entry starts Device N)

Fu Lights Off + N

Code + Fu 7 + N

(Entry  stops Device N)

Summary of Contents for LYNX

Page 1: ... 1 6HFXULW 6 VWHP 3URJUDPPLQJ RUP 6XPPDU RI RQQHFWLRQV AWAY OFF STAY AUX N8890V1 10 98 Previous Menu ...

Page 2: ...e number and account number fields press to end the entry if less than number maximum number of digits is entered 4 To delete an entry simply press plus that field number and reenter the correct data For phone number and account number fields 40 44 88 and 94 press field number INTERACTIVE MENU MODES There are six interactive menu modes as listed below To enter these modes first enter Program mode ...

Page 3: ...6 CHIME BY ZONE 1 0 no 1 yes program zones to chime on zone list 3 27 REAL TIME CLOCK DISPLAY 1 0 no 1 yes display time on keypad 29 DAYLIGHT SAVING TIME 4 10 START END MONTH Start End 1 9 10 11 12 Enter 0 0 if no daylight savings time used 30 DAYLIGHT SAVING TIME 1 5 START END WEEKEND Start End 0 disable 1 first 2 second 3 third 4 fourth 5 last 6 next to last 7 third from last ZONE SOUNDS AND TIM...

Page 4: ...enter up to the number of digits shown Do not fill unused spaces Enter 0 9 11 for 12 for 13 for a pause 40 PABX ACCESS CODE Enter 6 digits If fewer than 6 digits are entered pressing advances to the next field To clear entries from field press 40 41 PRIMARY PHONE No Enter up to 20 digits Do not fill unused spaces If fewer than 20 digits entered pressing advances to the next field To clear entries ...

Page 5: ... 00 and a 2 digit user or zone number 8 All reports Alarms Open Close Troubles See Installation Instructions for an explanation of 9 All except Open Close Open Close the pager code which takes the following form Will report users 5 8 or wireless AAAAAAAAAAAAAAAA EEE 00NN arm disarm button zones Where AAA optional 16 digits see field 88 26 33 all other zones and EEE 3 digit event code 911 alarm 101...

Page 6: ...sent as 2nd digit of the zone alarm report code programmed in 56 if expanded or 4 2 reporting is selected 60 TROUBLE REPORT CODE 1 0 61 BYPASS REPORT CODE 1 0 62 AC LOSS REPORT CODE 1 0 63 LOW BAT REPORT CODE 1 0 64 TEST REPORT CODE 1 0 65 OPEN REPORT CODE 1 66 ARM AWAY STAY RPT CODE 1 1 2nd digit is automatically sent as the user AWAY STAY number if expanded or 4 2 reporting is selected 67 RF XMT...

Page 7: ...larm Alarm Restore 2 Trouble Trouble Restore 4 Bypass Bypass Restore 8 Open Close Example To select Alarm Alarm Restore and Open Close enter 9 1 8 To select all enter 15 Note System messages are logged when any non zero selection is made 91 FUTURE USE 0 Must be 0 If inadvertently enabled the Contact ID event code 606 may be sent to the central station after an alarm report 92 No OF REPORTS IN ARME...

Page 8: ...e 4 Unsupervised RF UR Return to previous prompt 5 Button type BR l 0 LOOP NUMBER Enter the loop number l for this zone If L is displayed the serial number for this transmitter has already been entered You can keep the serial number and skip to the VOICE DESCRIPTOR prompt or you can continue to the DELETE SERIAL NUMBER prompt 0 to Delete Serial Number prompt F Continue to the ENROLL MODE prompt 1A...

Page 9: ...mode NOTE Entry of a number other than one specified will give unpredictable results Powerline Carrier Device Programming 0 Exit mode upon which this prompt blinks Press any field number to go to that field 1 Enter mode DEVICE NUMBER Enter the 2 digit device number 01 08 to be programmed Continue 00 Exit Device Programming mode displays blinking 80 enter desired data field or menu mode number b aa...

Page 10: ...ZONE NUMBER Enter the 2 digit zone number of the first transmitter to have its serial number entered Continue system searches for zones not yet entered then goes to ENROLL SERIAL NUMBER prompt C 00 Exit Sequential mode upon which the prompt 83 blinks Press any field number to go to that field zz ENROLL SERIAL NUMBER Enter the transmitter s 7 digit serial number printed on the transmitter If you en...

Page 11: ...nce to next zone prompt A zz zone descriptor will be announced Press any other key to repeat the selected word VOCABULARY INDEX 00 sec pause A 01 ALARM 02 ATTIC B 03 BABY 04 BACK 05 BASEMENT 06 BATHROOM 07 BEDROOM C 08 CHECK D 09 DEN 10 DETECTOR 11 DINING 12 DOOR E 13 EMERGENCY F 14 FIRE 15 FLOOR 16 FRONT G 17 GARAGE 18 GUN H 19 HALL I 20 INSIDE J K 21 KITCHEN L 22 LAUNDRY 23 LIBRARY 24 LIVING M 2...

Page 12: ...1 Type zt hex rc NOTE Zone 1 cannot be Wired Zone 1 0 1 00 00 00 used as a fire zone Duress 9 2 01 00 Keypad Panic 1 9 5 00 00 00 Keypad Panic 3 9 6 00 00 00 Keypad Panic 9 9 06 01 00 Zone No Zone Alarm Report Input Loop Transmitter Vocabulary A 01 Type zt Code in hex rc Type I No l Serial Number Index 0 2 01 01 00 3 2 16 12 99 0 3 01 01 00 3 2 04 12 99 0 4 03 01 00 3 2 42 99 99 0 5 10 01 00 3 1 2...

Page 13: ...lent 07 24 Hr Audible 08 24 Hr Aux 09 Fire 10 Interior w Delay 20 Arm Stay 21 Arm Away 22 Disarm 23 No Alarm Response 24 Silent Burglary rc ALARM REPORT CODE Two Hex Digits For each Hex Digit enter 00 09 for 0 9 10 for A 11 for B 12 for C 13 for D 14 for E 15 for F If 00 is entered as the first digit there will be no report for that zone For Contact ID reporting this is enabling code only Enter an...

Page 14: ... ANY zone on this list device action will START STOP RESTORE of ZONE LIST Upon restore of ALL zones on this list device action will STOP It need not be same list as used for START NOTE Do not assign zones with zone types 20 21 or 22 to a zone list ZT ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 06 24 Hr Silent 01 Entry Exit 1 07 24 Hr Audible 02 Entry Exit 2 08 24 Hr Aux 03 Pe...

Page 15: ...UX RIGHT 5818 ENROLL AS RF LOOP 1 5849 ENROLL AS RF LOOP 1 MOTION LOOP 1 MOTION 5890 ENROLL AS RF 5816 ENROLL AS RF LOOP 2 REED LOOP 1 TERMINALS 5827 SET HOUSE CODE 5827BD SET HOUSE CODE 5816MN ENROLL AS RF LOOP 2 REED LOOP 1 TERMINALS 5819 ENROLL AS RF LOOP 2 REED LOOP 1 TERMINALS ALTERNATE POSITION FOR LOOP 2 LOOP 3 TERMINALS YOU MUST ENROLL THIS BUTTON LOOP 3 LOOP 1 LOOP 2 LOOP 4 5804 ENROLL AS...

Page 16: ...CE 0 6B THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STAN DARD 72 CHAPTER 2 NATIONAL FIRE PROTECTION ASSOC BATTERYMARCH PARK QUINCY MA 02269 PRINTED INFORMATION DESCRIBING PROPER INSTALLATION OPERATION TESTING MAINTENANCE EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT PL513 POWERLINE INTERFACE LOCAL SOUNDER DISABLE J...