Push to set zone
Any zone can be wired and configured as a Push
to Set input. This can be a standard door bell
push located outside the premises After starting
the exit timer the building is vacated. As the
switch is then momentaraily closed, a chime
tone is produced and the system Sets.
Sometimes referred to as ‘Terminate Set’ this
facility is mandatory for communicating
systems installed to NACOSS guidelines
Remote keyswitch zone
Any zone can be wired and programmed as a
keyswitch input and used with a remote
keyswitch or lock switch. For security reasons it
is recommended that a tamper proof switch is
used and that the switch wiring is not accessible
from outside the premises.
The keyswitch may be used to Set (open
contacts) or Unset (closed contacts)
independently of RKPs. However in this
situation the keyswitch may have to ‘catch up’
with the system. For example if the system is Set
via an RKP and Unset with the keyswitch, it
would have to be momentarily turned to its Set
position then returned to its Unset position.
The keyswitch will always Set program 1. It will
also Unset the system or switch off an alarm
activation. To Reset after an alarm and return to
Day mode, the Reset key on the RKP will have
to be pressed.
Fire zone
Any zone may be programmed as a fire zone.
This will automatically exclude the availability
of the zone from programs and normal security
applications.
There are two types of fire zone,
Standard
and
24 hour
type. The
Standard fire
zone detects
fires only when the system is Set, where as the
24 hour fire
zone detects fires all the time and
will operate whether the system is Set or Unset.
A fire will cause a distinctive internal sounder
tone. The external sounders will pulse on and off
at 2 second intervals and all RKP indicators will
flash the affected zone.
PA circuit
Any quantity of normally closed type personal
attack button may be wired in series and then
connected to the PA circuit.
Operational in Day and Set, the PA circuit will
cause a full alarm condition when activated. PA
is indicated on the control panel or RKP as
Attack.
6
4PI175 issue 1_6/01
Engineering information
Accenta/Optima G3 Intruder system
Push
to
set
zone
J2
2
1
4
3
6
5
8
7
Panel
PA
+
-
TAMP +13V 0V
Board
Keyswitch
Note: A keyswitch can be
connected to any zone.
The zone must be programmed
for keyswitch application.
J2
2
1
4
3
6
5
8
7
Panel
PA
+
-
TAMP +13V 0V
Board
Fire detector
Note: Fire detector with
relay base for output
to intruder system.
J2
2
1
4
3
6
5
8
7
Panel
PA
+
-
TAMP +13V 0V
Board
Press to Set Switch
Note: The push to set switch
can be connected to any zone.
The zone must be programmed
for PTS application.