Access Codes
There are four codes used in the system, all are 4
digit and can be set to any number from 0000 to
9999. The access codes ensure that only
authorised users can operate the system.
User 1 and 2 codes
The user 1 and user 2 codes have the same
operation for testing, Setting and Unsetting, but
user 1 code which is usually considered to be the
Managers code has the authority to add, change
or delete the user 2 code and duress code.
Duress code
Should be used in a hold up situation where
there is pressure to Set or Unset the system.
Entry of the code will allow the system to work
normally but also generate a silent PA type
alarm by operating the PA communicator output.
Engineer code
Accesses the Engineer Program mode to allow
the system to be programmed. The engineer
code will not set or unset the system.
If configured the Engineers access code can be
used to reset the system after an alarm.
Note:
Entering an invalid user code will
operate the code tamper. After nineteen
incorrect key pushes a full alarm
condition will be generated.
4PI175 issue 1_6/01
13
Accenta/Optima G3 intruder system
Engineering information
Access
Codes
Reset
Reset
Codes
Change User code 1
Change User code 2
Change Duress code
Change Engineer code
2
3
9
1
8
ZONE 1-4
n
n
n
n
New code
ZONE 1-4
Rising beeps
Attack
Exit codes
Leave engineer mode
Day
Tamper
Attack
Acknowledge
Day
Day
NOTE
- The sounder will produce
a flat beep if the code is rejected. The Code
is rejected if it is already in use.
Enter Engineer program mode
Example: To change User 1 code to 3457
Press:
9
Prog
9
9
9
4
Reset
Reset
8
1
3
5
7