Installation Design
The purchase of this alarm system represents a
major step forward in the protection of the
property and its occupants. It is important to plan
the installation before proceeding and the follow
the procedures and advice contained in this
manual.
Plan the position of each part of
the alarm system and the cable
runs.
Detectors
should be sited
with particular regard to the
degree of coverage required
and the function of each of the zones.
All of the system wiring is
connected directly to the
panel
.
The Accenta panel may be
concealed inside a cupboard or
loft space, but it must be
installed within the protected
premises and in a position which is convenient
for a mains supply. The Optima panel may be
installed near an entry/exit point.
The
Remote keypads
(RKPs)
should be mounted in positions
which allows ease of operation
for the system users, typically
within the entry/exit route close
to the final door and the master bedroom.
Additional internal
sound
speakers
are recommended,
these will provide high volume
alarm tones and low volume
entry/exit tones. Speakers should
be positioned to provide good sound distribution
throughout the building and so that the exit tone
is audible outside the main entry / exit door.
This will enable the system operator to check
that the system is setting correctly.
Finally note that the
total
current
output of this
control system (in alarm
condition) is 1Amp when
supported by a fully charged
battery. Calculate the total
current consumption of every part of the system
including the panel, remote keypads,
bell/sounders, strobes and detectors to ensure
that this rating is not exceeded.
Depending on which area
you live, you may be
required, by law to notify
the
Local Authority
and
Police of the new security
alarm installation. The
local authority requirements may differ from
area to area, therefore, it is advisable to contact
local environmental officer to obtain full details
of your area requirements.
Fixing
Caution:
When positioning the control
panel ensure that it is located in a dry
place away from damp areas.
The Accenta mini G3 enclosure is illustrated
here, however the procedures for the other
panels are similar.
a.
Remove the front cover(s) from the
panel.
Disconnect the transformer wires from
the transformer marked
AC
terminals
on the board. Carefully remove the
PCB by gently pushing down the
holding clips on the bottom edge of the
PCB and withdraw it from the base.
4PI175 issue 1_6/01
3
Accenta/Optima G3 intruder system
Engineering information
Installation
Design
I
TOTAL
LA
Power
Accenta
/!
mini
0
1
2
3
5
6
7
8
Chime
Omit
Reset
4
9
Set
Prog
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
Tamper
Attack
Day
Power
PA
A
ccenta