Testing the system
Complete the wiring of the system and then:
ÿ
fully test the system and ensure it is fault
free.
ÿ
Fully program the system
ÿ
Fill in the installation log at the back of the
manual and retain if for future reference.
ÿ
Finally explain the operation of the system
to the end user. The Operating Instructions
are attached to the centre of this manual.
Detach them and leave them with the user.
Engineer program mode
The panel may be programmed to suit a wide
variety of installations. .
Once the
engineer program mode
has been
accessed, each configuration may be changed in
any order. As each configuration is completed
the system will automatically return to top level
of engineering program mode.
Before entering
engineer program mode
the
system should be in the Day mode, with the Day
and Power indicators lit.
Key
To exit
System indications
- Unset system indication
- Set system indication
To enter Engineer program mode
Note:
The factory configured engineer’s
access code is 9999. If however this code
is changed then enter the appropriate
code.
To Exit Engineer program mode
To reset panel to Factory set
conditions
CAUTION:
All configurations of the
panel are restored to factory ‘default’
conditions.
12
4PI175 issue 1_6/01
Engineering information
Accenta/Optima G3 Intruder system
Testing
the
system
Reset
Day
Prog
9
9
9
9
Tamper
Day
ZONE 1 - 8
Momentarily On
Acknowledge
Power
Day
Power
Reset
Quit the current function
Leave program menu
Down one menu level
LED steady On indication
LED Off
Strobe
Bell
NOTE: In general a flat beep is
an indication of an incorrect key press.
Sound description
Internal sound
External devices
ARC
o/p
Output to Alarm Receiving Centre
Communicator outputs are not applicable for
Optima compact G3 panel
LED flashing indication
reset beeps
Within 5 seconds of
powering up the panel
Reset
Reset