ADE Accenta G3 Engineering Information Download Page 21

Bell and Service Timers

4PI175 issue 1_6/01

21

Accenta/Optima G3 intruder system

Engineering information

Bell

and

Service

Timers

Reset

Reset

Reset

Anti-code
reset site code

Zone 1

Zone 2

0

0

0

1

0

2

0

3

2

0

Continous operation

1 minute bell duration

3 minute bell duration

20 minute bell duration
(factory default)

9

9

99 minute bell duration

2 minute bell duration

Zone 1

Zone 2

0

0

0

1

0

2

0

3

2

0

No delay
(Factory default)

1 minute bell duration

3 minute bell duration

20 minute bell duration

9

9

99 minute bell duration

2 minute bell duration

Acknowledge

100 Set/Unset

1

Zone 1

Press

a

number

button

to

select

Service

timer

300 Set/Unset

3

Zone 3

200 Set/Unset

2

Zone 2

500 Set/Unset

5

Zone 5

400 Set/Unset

4

Zone 4

600 Set/Unset

6

Zone 6

800 Set/Unset

8

Zone 8

700 Set/Unset

7

Zone 7

Service timer disabled
(Factory default)

0

Lit when selected

Timers and
Counters

Bell timer

Bell delay timer

Service timer

Re-arm counter
(00 to 99)

2

3

4

1

5

7

Attack

Leave engineer mode

Exit Timer and counters

ZONE 1 - 8
Momentarily On

Appropriate
Set / Unset
values LED is
lit

Exit

Day

Day

Day

Attack

Day

Tamper

Acknowledge

Day

Enter Engineer program mode

Example: To set bell timer for 10 minutes duration, Press:

7

Prog

9

9

9

9

0

Reset

Reset

1

1

Summary of Contents for Accenta G3

Page 1: ...Optima compact G3 panel with built in keypad Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog PA Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini...

Page 2: ...t in keypad 2 4PI175 issue 1_6 01 Engineering information Accenta Optima G3 Intruder system Features Contents Features 2 Installation Design 3 Fixing 3 Wiring the system 5 Tamper network 5 Connect Rem...

Page 3: ...able the system operator to check that the system is setting correctly Finally note that the total current output of this control system in alarm condition is 1Amp when supported by a fully charged ba...

Page 4: ...he ve line of 12V battery F2 1A to protect the RKP 13V supply F3 1A to protect the Speaker 13V supply F5 1A to protect the Bell and Strobe supply As supplied wire links are fitted across the PA and Ta...

Page 5: ...being installed ensure there is at least one remote keypad wired to the panel before first power up A combination of up to four remote keypads and lighting controller can be connected to the panel Se...

Page 6: ...to be pressed Fire zone Any zone may be programmed as a fire zone This will automatically exclude the availability of the zone from programs and normal security applications There are two types of fi...

Page 7: ...position from where the bell could be seen and heard Terminal T A D B are for connection to the external bell or sounder These terminals provide a power hold off supply sounder trigger and tamper circ...

Page 8: ...s activated when pulled to 0V by the telephone line fault output of the communicator This is usually a voltage free relay or open collector transistor When a telephone line fault occurs in the Day mod...

Page 9: ...nd abort is being used care should be taken to ensure that the abort connection cannot be damaged or severed as this could cause the ARC to incorrectly filter an alarm signal d It is very important th...

Page 10: ...unce period 300mS ALL zones Flag A Silent PA No RKP PA Enable Yes Engineer Reset No Anti Code Reset No Door bell on push to set No Single key setting No Strobe on setting No External bell on Fire No F...

Page 11: ...t by setting them to disabled using the Zone Type function see page 19 Mains Connection The mains power should be connected using a 3 core cable of not less than 0 75mm sq from a fused spur to the mai...

Page 12: ...Key To exit System indications Unset system indication Set system indication To enter Engineer program mode Note The factory configured engineer s access code is 9999 If however this code is changed...

Page 13: ...cesses the Engineer Program mode to allow the system to be programmed The engineer code will not set or unset the system If configured the Engineers access code can be used to reset the system after a...

Page 14: ...allows access to the Entry Exit zone However if the panel is set and an time inhibited zone is triggered before an Entry Exit zone then an alarm will be generated immediately Immediate This is a zone...

Page 15: ...one 1 Day Day Day Input Entry Exit time respectively 0 1 0 2 0 3 20 seconds duration Acknowledge 10 seconds duration 30 seconds duration factory default Zone n selected Zone n deselected 5 6 7 2 3 4 1...

Page 16: ...for zone 5 flat x2 for zone 6 flat x4 for zone 8 Rapid for PA Rapid for Tamper Zones Strobe Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 Walk test 6 Strobe On Bell on internal...

Page 17: ...alarm When the flag is clear the system can be reset by the user Anti code Reset When this flag is set it enables the anti code reset function Enable Door bell on PTS When this flag is set it allows a...

Page 18: ...s set it configures the polarity of line fail input User Reset PA When this flag is set it permits the user code to reset the system after a PA alarm even if Engineer reset flag is set User Reset Fire...

Page 19: ...e Zone 6 type Zone 8 type 5 6 8 2 3 4 1 5 Attack All Zones Press a number button to select Zone to be configured Press a number button to select zone type Day Exit to zone type Exit zone configuration...

Page 20: ...ributes Zone Attributes Double Knock Omit Prevent Zone Delay 2 3 1 6 Attack Zone n selected Zone n deselected 5 6 7 2 3 4 1 8 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Press number butto...

Page 21: ...uration 2 minute bell duration Acknowledge 100 Set Unset 1 Zone 1 Press a number button to select Service timer 300 Set Unset 3 Zone 3 200 Set Unset 2 Zone 2 500 Set Unset 5 Zone 5 400 Set Unset 4 Zon...

Page 22: ...it anti code would be given to the user which would reset the system This anti code is generated from a small computer program which is installed at most UK Alarm receiving Centres or alternatively ca...

Page 23: ...l All Zones 5 6 7 2 3 4 1 8 To assign zones to channel press to select and again to deselect zone Factory default No zones are selected Zone n assigned to the channel Zone n not assigned to the channe...

Page 24: ...the tamper wiring When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high f If totally lost as to the cause of a fault remove ALL wiring fro...

Page 25: ...Alarm 70mA Low voltage output 13 8V dc stabilised 5 up to 350mA Rechargeable Battery Accenta Optima G3 mini compact 12V 1 2 or 2 1Ah Accenta Optima G3 12V up to 7Ah Charge Voltage 13 8V dc 5 PCB Fuse...

Page 26: ...0 23 Line Fail 10 Local Authorit 3 M Mains 11 25 Managers code 13 N NACOSS 6 9 NACP 14 9 Normally closed detectors 24 Normally open detector 24 NVM 2 9 O Omit prevent 10 20 Operating temperature 25 P...

Page 27: ...SP 400 Accenta mini G3 panel 8EP 395 Optima G3 8EP 396 Optima compact G3 panel 8EP 219 Accenta LED RKP 8EP 332 Accenta LCD RKP 8EP 336 Accenta Speech Dialler 8EP 276 Informa 8EP 289 Extension Speaker...

Page 28: ...2 3 4 1 4 Zone Attributes see page 20 Double Knock Omit Prevent Zone Delay 2 3 1 6 Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 6 9 9 9 9 Engineer Program Mode Prog To exit eng...

Page 29: ...have only the Power indicator lit This is an armed system indication 4PI175 issue 1_6 01 1 Unset system indications 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZO...

Page 30: ...ll of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Program 3...

Page 31: ...it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How to unset the system t...

Page 32: ...et When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing Reset...

Page 33: ...scroll starts with the newest event number 8 to the oldest one number 1 4PI175 issue 1_6 01 5 Accenta Optima G3 intruder system Operating instructions Operator s Program mode Reset Quit the current f...

Page 34: ...n n n New code Or Omit To omit the user 2 code ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operat...

Page 35: ...one 5 Zone 6 Zone 7 Zone 8 T Timed Entry Exit Zone TI Time Inhibited Access zone to keypad I Immediate All zones armed to give full alarm 4PI175 issue 1_6 01 7 Accenta Optima G3 intruder system Operat...

Page 36: ...m Set the system or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day ARC o p Se...

Reviews: