RS232 port – debug port
This port is intended for capturing the debug log. The cable length is limited to 10
metres. Use Belden cable no. 9533 or equivalent.
• Connect the wires as shown below.
NOTE
: The sample wires below are used for reference. You may use different colour
wires that met the electrical specifications.
Black wire - terminal block 22 (GND)
Red wire - terminal block 24 (RS232-TX)
White wire - terminal block 23 (RS232-RX).