IRIS-4 160

 

Quick Installation and

Maintenance Guide

IRIS-4 160

9

8

6.5. 4g/3g/2g SIM Card

DO NOT FIT SIM card until after you have 
performed the 4G/3G/2G Network Scan detailed in 
the Section 6 .9 “Configuration” . You will be prompt-
ed when to insert the SIM card .

6.6. Dial Capture

Dial Capture enabled systems: Connect the two dial 
screw terminals to the alarm panel dialler telecoms 
line connection . If the alarm panel has screw connec-
tions .

Note: Polarity is not important in this instance. 
For EN 50136-2: 2013 compliance fit the supplied 
18K sense resistor in parallel with the dialler output 
of the alarm panel, at the alarm panel end of the 
cable. 

Note: This resistor enables the dialler to detect 
cable faults and/or tampers, the Monitoring Centre 
will also need to enable the dial port monitoring 
on the IRIS Secure Apps software to receive alarm 
notifications.

6.7. Pin Inputs

The IRIS-4 160 dialler has four pin inputs that can be 
used to generate messages, These can be:

•  Text messages via SMS (4G/3G/2G).
•  SIA, Contact ID or Fast Format alarm messages  
 

over IP to the monitoring centre .

Note: You can also use the Pin alarm inputs in 
addition when directly connected to an alarm panel 
via the dial capture, serial or RS485 connections.

Via Open/Close Contact Source

Each pin input is designed to be connected in a loop 
via an open/close contact source from an alarm pan-
el, or other device, to a reference ground pin available 
on the IRIS-4 160 dialler, as shown below .

Opening the contact (i .e . loop is open circuit) 
generates an alarm signal . Closing the contact gener-
ates the equivalent restore signal .

Via Sense Resistors

It is also possible to link the contacts to the IRIS-4 
160 dialler via sense resistors so that an open or short 
circuit tamper on the loop is detectable and the 
Monitoring Centre alerted . In this case, the connec-
tions made should be as shown below .

Note: For this feature to work correctly it is 
essential to connect the resistor at the contact end 
of the loop and not the dialler end. The Monitoring 
Centre must also enable the monitoring of this 
facility on the dialler within the IRIS Secure Apps 
receiving system. 

6.8. Switch on

To confirm power is applied, look for the indicator 
‘SYS LED’ flashing red on the IRIS-4 160 dialler 
board, top left hand corner .

6.9. Configuration

To configure the dialler, use any of the following the 
methods:
•  Web browser via Wi-Fi.
•  AddSecure IRIS Bluetooth App.
•  Alarm panel integration e.g. Honeywell Galaxy  
 

(RS485 connection) Texecom Premier range  

 

(RS232 TTL connection) .

Note: Please configure the alarm panel first for 
connections to Honeywell Galaxy or Texecom 
Premier on the serial integration, as these will 
transmit configuration to the IRIS-4 160 dialler.
For more details on the alarm panel integration, 
download the full panel installation manual from 
http://www.addsecure.com.

•  Connect the board’s Micro USB connector to  
 

a laptop/PC running the IRIS Toolbox soft- 

 

ware . Download the IRIS Toolbox user guide  

 

from http://www .addsecure .com . 

Defaulting

If at any point a complete default of the dialler is 
required, use the following procedure:
1 .  Completely power down the IRIS-4 160 by 
 

removing the power and one of the batteries 

 

(if fitted) .

2 .  Now press and hold down the AP button .

3 .  Reconnect the batteries if needed and reapply  
 

power whilst still holding down the AP button  

 

for 10 seconds . 

Summary of Contents for IRIS-4 160

Page 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 160 Quick Installation and Maintenance Guide...

Page 2: ...mission System ATS configuration up to SP3 for single path or ATS configuration DP2 for dual path The IRIS 4 160 is based on the successful IRIS Touch NG range of AoIP diallers with the same hardware...

Page 3: ...en the following information will not be required as it will be assigned by the network IP address Gateway address Subnet mask address Wi Fi Connection Details The customer s Wi Fi network details are...

Page 4: ...tened or other activities such as alarm alerting by the panel at regular intervals If batteries are required DO NOT FIT until indicated in Section 6 9 Configuration Use Batteries approved to IEC61951...

Page 5: ...s the equivalent restore signal Via Sense Resistors It is also possible to link the contacts to the IRIS 4 160 dialler via sense resistors so that an open or short circuit tamper on the loop is detect...

Page 6: ...local Configuration viaWeb Browser usingWi Fi Connection Can be configured using the Wi Fi connection using a standard Web browser from any smartphone tablet or laptop device and supports the followin...

Page 7: ...and follow the on screen prompts Note 1 If installing the IRIS 4 160 without batteries then please untick the Use battery backup option Note 2 During the Installation Wizard the Wi Fi status screen a...

Page 8: ...heck battery status and replace if below required level Reflash IRIS 4 160 software to latest version Test the configured communication paths Ethernet Wi Fi 4G 3G 2G Perform full test of alarms from t...

Page 9: ...atteries fitted for backup purpose replaced them every two years 7 4 Check SoftwareVersion Reflash Go to the settings menu and then select Latest software this will then check with the AddSecure Refla...

Page 10: ...up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 reference SIA DC 03 1990 01 R2003 10 Contact ID reference SIA DC 05 1999 09 Fast format Scancom for dial capture and serial connection...

Page 11: ...s are connected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltag...