background image

 

INNEHOLD:

• 

Airborne DC kretskort

 

Mål (BxHxD): 58x105x25 mm

• 

Ladekort

• 

Plastkabinett, sabotasjesikret.

 

Mål (BxHxD): 170x160x60 mm

• 

1stk. NiMH 2200  mAh batteri

• 

Ekstern 15 VDC strømadapter

• 

Integrert SIM-kort (e-SIM) med 

 

tilhørende AddSecure  abonnement

• 

Hurtigmanual

• 

Informasjon og support

• 

Intern antenne

• 

Monteringsskruer

• 

Alarmetikett

AIRBORNE 

DC MEDIUM

Hurtigmanual/
Snabbguide

 

INNEHÅLL:

• 

Airborne DC kretskort

 

Mått

(BxHxD):

 58x105x25  

mm

• 

Laddkort

• 

Plastkapsling, sabotagesäker.

 

Mått (BxHxD): 170x160x60  

mm

• 

1st. NiMH 2200  mAh batteri

• 

Extern 15 VDC strömadapter

• 

Integrerat SIM-kort (e-SIM) med

 

tillhörande AddSecureabonnemang

• 

Snabbguide

• 

Information och support

• 

Intern antenn

• 

Monteringsskruvar

• 

Dekaler

GODKJENNELSER/GODKÄNNANDE

2544-CPr -P20727-F03-16

EN54-21:2006 Type 1
EN50136-1:2012 ATS: SP4
EN50136-2:2013
EN50131-1:2006/A1:2009 

g

R2 ECII

UMTS: ATS5

EN50130-4:2011
EN50130-5:2011
SBF110:7
SSF114:2 Larmklass 2

IRIS-4 160

 

Quick Installation and

Maintenance Guide

Summary of Contents for IRIS-4 160

Page 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 160 Quick Installation and Maintenance Guide...

Page 2: ...mission System ATS configuration up to SP3 for single path or ATS configuration DP2 for dual path The IRIS 4 160 is based on the successful IRIS Touch NG range of AoIP diallers with the same hardware...

Page 3: ...en the following information will not be required as it will be assigned by the network IP address Gateway address Subnet mask address Wi Fi Connection Details The customer s Wi Fi network details are...

Page 4: ...tened or other activities such as alarm alerting by the panel at regular intervals If batteries are required DO NOT FIT until indicated in Section 6 9 Configuration Use Batteries approved to IEC61951...

Page 5: ...s the equivalent restore signal Via Sense Resistors It is also possible to link the contacts to the IRIS 4 160 dialler via sense resistors so that an open or short circuit tamper on the loop is detect...

Page 6: ...local Configuration viaWeb Browser usingWi Fi Connection Can be configured using the Wi Fi connection using a standard Web browser from any smartphone tablet or laptop device and supports the followin...

Page 7: ...and follow the on screen prompts Note 1 If installing the IRIS 4 160 without batteries then please untick the Use battery backup option Note 2 During the Installation Wizard the Wi Fi status screen a...

Page 8: ...heck battery status and replace if below required level Reflash IRIS 4 160 software to latest version Test the configured communication paths Ethernet Wi Fi 4G 3G 2G Perform full test of alarms from t...

Page 9: ...atteries fitted for backup purpose replaced them every two years 7 4 Check SoftwareVersion Reflash Go to the settings menu and then select Latest software this will then check with the AddSecure Refla...

Page 10: ...up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 reference SIA DC 03 1990 01 R2003 10 Contact ID reference SIA DC 05 1999 09 Fast format Scancom for dial capture and serial connection...

Page 11: ...s are connected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltag...