IRIS-4 160
Quick Installation and
Maintenance Guide
IRIS-4 160
19
18
8. SPeCIFICatIonS
transmission paths
IRIS-4 160
Ethernet
Standard
UTP 10/100 Base T with auto-negotiation
Connection
RJ45 socket for CAT5 cabling
IP addressing
Dynamic (DHCP) or fixed
Fault detection
Loss of Ethernet synchronisation
Wi-Fi
Standard
IEEE 802 .11 b/g
Connection
2 .4GHz b/g/n with internal PCB chip antenna
Fault detection
Loss of association/data
4G/3G/2G
Frequencies
Penta band LTE (4G)
800/900/1800 MHz
2100/2600 MHz
Dual band UMTS (3G)
900/2100 MHz
Dual band GSM (2G)
900/1800 MHz
Connection
SMA socket for antenna
Fault detection
Loss of registration with network
IP
TCP ports (outbound)
53165 (Alarms & Polling), 51292 (Diagnostic & Reflashing),
10001 (Upload/Download)
Alarm transmission
Interface to Monitoring Centre
IRIS Secure Apps or IRIS Management Suite via
EN 50136-2 pass-through mode
Dial capture interface to alarm panel
Two wire interface via terminal block
Note: Cabling must not exceed 3 meters
Serial interface to alarm panel
RS485, TTL, RS232
Note: RS232 cabling must not exceed 3 meters
transmission paths
IRIS-4 160
Alarm transmission
PIN Inputs interface to alarm panel Maximum input voltage range 0V to +24V
Input ‘low’ (alarm) threshold < 1V
Input ‘high’ (restore) threshold > 2V
Internal pull-up impedance 10K to 3 .3V supply
Alarm protocols
SIA (level 1 to 3) reference SIA DC-03-1990 .01(R2003 .10)
Contact ID reference SIA DC-05-1999 .09
Fast format (Scancom) for dial capture and serial connections
Robofon (Dial capture only)
Telim (Dial capture only)
CESA (Dial capture only)
Tamper detection reporting to
Dial capture interface, lid & back tamper, serial interface, pin inputs
Monitoring Centre
Fault reporting to Monitoring Centre External power supply fail, low battery, transmission interface/path fault
Relay outputs
Maximum operating voltage
24V DC
Maximum current rating
100mA DC
Power supply
Supply voltage
9V to 17V DC
Typical current
83mA @ 12V DC
Maximum current
1A @ 12V DC
Recommended external PSU
12V DC 1A 12 Watt
Note: For Radio Equipment Directive the power cable needs to be
no longer than 3 meters in length
Power storage
Storage device type
4 x AA NiMH rechargeable batteries
Storage device capacity
2000mAh
Storage device time to recharge to 80% capacity
32 hours
Storage device – voltage at which fault is reported
4 .5V DC
Storage device – voltage at which fault is restored
5V DC
Storage device – over voltage protection triggered
6 .5V DC
Storage device – deep discharge protection
4V DC
Environmental
Operating temperature range
-10°C to 55°C
Operating humidity range
95% max ., non-condensing
Weights and Dimensions
Physical dimensions (L x W x D)
11 .5 cm x 17 .5 cm x 4 .5 cm
PCB weight
400 grams
Fully packaged weight
600 grams
Note:
Cabling must not
exceed 3 meters