8. SPeCIFICatIonS

transmission paths 

 

IRIS-4 160

Ethernet
 

Standard 

UTP 10/100 Base T with auto-negotiation

 

Connection 

RJ45 socket for CAT5 cabling

 

IP addressing 

Dynamic (DHCP) or fixed

 

Fault detection 

Loss of Ethernet synchronisation

Wi-Fi 
 

Standard 

IEEE 802 .11 b/g

 

Connection 

2 .4GHz b/g/n with internal PCB chip antenna

 

Fault detection 

Loss of association/data

4G/3G/2G 
 

Frequencies 

Penta band LTE (4G)

 

 

800/900/1800 MHz

 

 

2100/2600 MHz

 

 

Dual band UMTS (3G)

 

 

900/2100 MHz

 

 

Dual band GSM (2G)

 

 

900/1800 MHz

 

Connection 

SMA socket for antenna

 

Fault detection 

Loss of registration with network

IP 
 

TCP ports (outbound) 

53165 (Alarms & Polling), 51292 (Diagnostic & Reflashing), 

 

 

10001 (Upload/Download)

Alarm transmission
Interface to Monitoring Centre 

IRIS Secure Apps or IRIS Management Suite via 

 

 

EN 50136-2 pass-through mode

Dial capture interface to alarm panel 

Two wire interface via terminal block

 

 

Note: Cabling must not exceed 3 meters

Serial interface to alarm panel 

RS485, TTL, RS232 

Note: RS232 cabling must not exceed 3 meters

transmission paths 

 

IRIS-4 160

Alarm transmission 
PIN Inputs interface to alarm panel  Maximum input voltage range 0V to +24V 

 

 

 

Input ‘low’ (alarm) threshold < 1V 

 

 

Input ‘high’  (restore) threshold > 2V 

 

 

Internal pull-up impedance 10K to 3 .3V supply

Alarm protocols 

SIA (level 1 to 3) reference SIA DC-03-1990 .01(R2003 .10)

 

 

Contact ID reference SIA DC-05-1999 .09

 

 

Fast format (Scancom) for dial capture and serial connections

 

 

Robofon (Dial capture only)

 

 

Telim (Dial capture only)

 

 

CESA (Dial capture only)

Tamper detection reporting to 

Dial capture interface, lid & back tamper, serial interface, pin inputs

Monitoring Centre 
Fault reporting to Monitoring Centre  External power supply fail, low battery, transmission interface/path fault
Relay outputs
Maximum operating voltage 

24V DC

Maximum current rating 

100mA DC

Power supply
Supply voltage 

9V to 17V DC

Typical current 

83mA @ 12V DC

Maximum current 

1A @ 12V DC

Recommended external PSU 

                 12V DC 1A 12 Watt 

 

 

Note: For Radio Equipment Directive the power cable needs to be 

 

 

no longer than 3 meters in length 

Power storage
Storage device type 

 

4 x AA NiMH rechargeable batteries

Storage device capacity 

 

2000mAh

Storage device time to recharge to 80% capacity 

32 hours

Storage device – voltage at which fault is reported 

4 .5V DC

Storage device – voltage at which fault is restored 

5V DC

Storage device – over voltage protection triggered 

6 .5V DC

Storage device – deep discharge protection 

4V DC

Environmental
Operating temperature range 

-10°C to 55°C

Operating humidity range 

95% max ., non-condensing

Weights and Dimensions
Physical dimensions (L x W x D) 

11 .5 cm x 17 .5 cm x 4 .5 cm

PCB weight 

400 grams

Fully packaged weight 

600 grams

 

Note:
Cabling must not
exceed 3 meters

Summary of Contents for IRIS-4 160

Page 1: ...AIRBORNE DC MEDIUM Hurtigmanual Snabbguide IRIS 4 160 Quick Installation and Maintenance Guide...

Page 2: ...mission System ATS configuration up to SP3 for single path or ATS configuration DP2 for dual path The IRIS 4 160 is based on the successful IRIS Touch NG range of AoIP diallers with the same hardware...

Page 3: ...en the following information will not be required as it will be assigned by the network IP address Gateway address Subnet mask address Wi Fi Connection Details The customer s Wi Fi network details are...

Page 4: ...tened or other activities such as alarm alerting by the panel at regular intervals If batteries are required DO NOT FIT until indicated in Section 6 9 Configuration Use Batteries approved to IEC61951...

Page 5: ...s the equivalent restore signal Via Sense Resistors It is also possible to link the contacts to the IRIS 4 160 dialler via sense resistors so that an open or short circuit tamper on the loop is detect...

Page 6: ...local Configuration viaWeb Browser usingWi Fi Connection Can be configured using the Wi Fi connection using a standard Web browser from any smartphone tablet or laptop device and supports the followin...

Page 7: ...and follow the on screen prompts Note 1 If installing the IRIS 4 160 without batteries then please untick the Use battery backup option Note 2 During the Installation Wizard the Wi Fi status screen a...

Page 8: ...heck battery status and replace if below required level Reflash IRIS 4 160 software to latest version Test the configured communication paths Ethernet Wi Fi 4G 3G 2G Perform full test of alarms from t...

Page 9: ...atteries fitted for backup purpose replaced them every two years 7 4 Check SoftwareVersion Reflash Go to the settings menu and then select Latest software this will then check with the AddSecure Refla...

Page 10: ...up impedance 10K to 3 3V supply Alarm protocols SIA level 1 to 3 reference SIA DC 03 1990 01 R2003 10 Contact ID reference SIA DC 05 1999 09 Fast format Scancom for dial capture and serial connection...

Page 11: ...s are connected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltag...

Reviews: