SECTION 15: R
EPLACEMENT
P
ARTS
51 of 59
15.8 Flue Blower for Models UHA[T][X][S] 150-175
Rear Panel
Gasket
Mounting
Plate
Flue Fan
Vent Box
Rear Panel
Flue Fan
Vent Box
Gasket
Remove screws securing outlet flange to the flue
adapter.
Refit in reverse order.
Disconnect electrical connections at plug in tabs.
Remove screws securing flue fan mounting plate
to vent box.
Remove screws securing mounting plate to fan.
(Not shown)
Refit in reverse.
Use new gaskets.
Ensure sealed joints.
Ensure mounting plate orifice is clear and not
obstructed.
MODEL
UHA[X][S]
150 - 175
Flue Blower P/N
90710405
IT IS IMPORTANT THAT ONLY THE CORRECT FLUE BLOWER SPECIFIED FOR EACH MODEL TYPE
IS USED WHEN REPLACING THESE ITEMS.
Carry out a start-up after working on or changing an flue blower.
Summary of Contents for UHAS 150
Page 2: ......
Page 4: ......
Page 8: ......
Page 48: ...UHA STANDARD UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL 40 of 59 14 1 General...
Page 68: ...UHA STANDARD UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL 60 of 59...
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......