UHA S
TANDARD
U
NIT
H
EATER
I
NSTALLATION
O
PERATION AND
S
ERVICE
M
ANUAL
54 of 59
15.11 Pressure Switch
Carbon Monoxide Hazard
Use correct pressure switch specified for each
model.
Use of incorrect pressure switch or disabling
pressure switch circuit could cause unsafe
condition.
Failure to follow these instructions can result in
death or serious injury.
WARNING
Pull off 3 way connector. Spring open plastic clips of mounting cradle. Replace with correct type of
pressure switch for model. The pressure switches are color coded for each pressure setting.
Carry out a start-up after working on or changing a pressure switch.
MODEL
UHA[T][X][S]
150 - 175
UHA[T][X][S]
200 - 225
UHA[T][X][S]
250
UHA[X][S]
300 - 350
UHA[X][S]
400
15.12 Ignition Control
The control mounts to the electrical plate. Pull out ignition cable and wiring from board, noting their
positions. Release the four mounting standoffs. Refit in reverse. Ensure correct location of ignition cable
and all other wiring.
15.13 Axial Fan/Guard/Motor Assembly
The axial fan unit for the heater is supplied completely assembled and balanced
MODEL
UHA[T][X][S] 150 - 175
UHA[T][X][S] 200- 250
UHA[X][S] 300 - 400
Axial Fan Blade
Pressure Switch
Kit P/N
90439802
90439808
90439812
90439807
90439808
Color Code
yellow
orange
orange
brown
orange
Set Point in. w.c.
0.32
0.79
0.18
0.68
0.79
Pressure Switch Snap
Ring P/N
90439850
90439850
90439850
90439850
90439850
Axial Fan Guard
91901104
91901104
91901105
Axial Fan Motor
90600107
90600107
90600106
90709006
90709006 90709005
Summary of Contents for UHAS 150
Page 2: ......
Page 4: ......
Page 8: ......
Page 48: ...UHA STANDARD UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL 40 of 59 14 1 General...
Page 68: ...UHA STANDARD UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL 60 of 59...
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......