SECTION 15: R
EPLACEMENT
P
ARTS
47 of 59
15.3 Burner Compartment for Models UHA[X][S] 300-400
Remove flexible
air duct from spigot
Remove
access plate
Remove screws and
pull off burner
compartment cover
Viewing port
for flame probe
Viewing port
for ignition electrode
Flame Probe
Burner
Compartment
Cover
Rubber Seal
Ignition Electrode
The burner compartment is
a sealed compartment.
Following any work,
re-seal the compartment
with the gas pipe rubber
seal fully in place and all
screws fitted and tight.
NOTE:
Flexible duct only applies
for model UHAS.
15.3.1
Screws
Manifold
Inshot
Burners
Orfices
Burner
Screws
Burner
venturi
Unscrew
Orfice
Manifold
Marking
Inshot
Burner
Ensure gas tight fitting of injectors.
Ensure correct alignment with burners.
Ensure all pipe joints are gas tight.
Burner Injectors for Models UHA[X][S] 300-400
MODEL
UHA[X][S] 300
UHA[X][S] 350
UHA[X][S] 400
Orifice Quantity
12
14
14
Natural Gas (G20)
Orifice Marking
40
40
40
P/N
91930040
91930040
91930040
Propane (G31)
Orifice Marking
1.45 mm
53
53
P/N
91930145
91930053
91930053