Functions of the board
APCI-1710
54
Example:
The incremental transmitters are programmed with reference logic in the
function modules 1 to 4. The corresponding I/O function range for the
“incremental transmitter” will be copied into the therefore allocated places
of the function modules.
The following I/O range is built:
Table 9-2: I/O range
IORD / IOWR
D31...D24
D23...D16
D15.....D8
D7.......D0
BYTES HIGHBYTE
MIDHIGHBYTE
MIDLOWBYTE
LOWBYTE
BASE+0 Incremental
counter
1
BASE +59
Incremental counter 1
BASE +60 bis +63
Function module 1 - Info
SCxx
BASE+64 Incremental
counter
2
BASE+ 123
Incremental counter 2
BASE + 124 bis + 127
Function module 2 - Info SCxx
BASE+128
Incremental counter 3
BASE+187 Incremental
counter
3
BASE +188 bis +191
Function module 3 - Info SCxx
BASE+192 Incremental
counter
4
BASE+251 Incremental
counter
4
BASE +252 bis +255
Function module 4 - Info SCxx
SC: Incremental counter
xx: Number of version, e.g. SC23 Version 2.3
All settings on the board are realized through the software (AP), through the
connector assignment or through a reprogramming of the function module
(no jumper on the board).
Summary of Contents for APCI-1710
Page 13: ...Handling of the board APCI 1710 12 3 HANDLING OF THE BOARD Fig 3 1 Correct handling ...
Page 20: ...APCI 1710 Technical data 19 4 5 Component scheme Figure 4 1 Component scheme ...
Page 78: ...APCI 1710 Standard software 77 1 No interrupt 0 IRQ number ...
Page 84: ...APCI 1710 Index 83 V Versions 14 W Weight 13 ...