Standard software
APCI-1710
80
Table 10-4: Filter time
b_TimeBase
APCI1710_30MHZ
APCI1710_33MHZ
APCI1710_40MHZ
b_Filter
0
Filter not used
Filter not used
Filter not used
1
133 ns
121 ns
100 ns
2
200 ns
182 ns
150 ns
3
267 ns
242 ns
200 ns
4
333 ns
303 ns
250 ns
5
400 ns
364 ns
300 ns
6
467 ns
424 ns
350 ns
7
533 ns
485 ns
400 ns
8
600 ns
545 ns
450 ns
9
667 ns
606 ns
500 ns
10
733 ns
667 ns
550 ns
11
800 ns
727 ns
600 ns
12
867 ns
788 ns
650 ns
13
933 ns
848 ns
700 ns
14
1000 ns
909 ns
750 ns
15
1067 ns
970 ns
800 ns
i
IMPORTANT!
This function is only availabe for the following modules:
Chronos, pulse counter, incremental counter
Calling convention:
ANSI C :
int
i_ReturnValue;
unsigned char
b_BoardHandle;
i_ReturnValue =
i_APCI1710_InitInputFilter
(b_BoardHandle
0,
APCI1710_40MHz,
9);
Return value:
0: No error
-1: Handle parameter of the board is wrong
-2: Selected module number is wrong.
-3: The selected module has no input filter.
-4: The selected filter clock is wrong.
-5: The selected filter time is wrong.
-6: No 40 MHz quartz is available on the board.
Summary of Contents for APCI-1710
Page 13: ...Handling of the board APCI 1710 12 3 HANDLING OF THE BOARD Fig 3 1 Correct handling ...
Page 20: ...APCI 1710 Technical data 19 4 5 Component scheme Figure 4 1 Component scheme ...
Page 78: ...APCI 1710 Standard software 77 1 No interrupt 0 IRQ number ...
Page 84: ...APCI 1710 Index 83 V Versions 14 W Weight 13 ...