![Addi-Data ADDICOM PA 7300 Technical Description Download Page 14](http://html1.mh-extra.com/html/addi-data/addicom-pa-7300/addicom-pa-7300_technical-description_2848826014.webp)
Technical description Chapter 4
PA 7300
7
4.3 Limit
values
Operating temperature: .................................... 0 to 60
°
C
Storage temperature: ........................................ -25 to 70
°
C
Relative humidity: ........................................... 30% to 99% non condensing
Minimum PC requirements:
- operating system: ........................................... MS DOS 3.3 or >
Windows 3.1
- bus speed: ...................................................... 8 MHz
Energy requirements:
- operating voltage of the PC: .......................... 5V
±
5%
- current consumption in mA(without load): typ. See table
±
10%
PA7300
+ 5 V from PC
63 mA
Add to this data the current consumption of the used
modules according to following table.
PMxxx
PMxxx-G
RS232
21 mA
48 mA
RS422
5 mA
42 mA
RS485
5 mA
53,5 mA
20mA 51
mA -
1 Module
PMTTY (20 mA)
is isolated as a standard.