Specifications for the ENIU are listed in 

Table A-1

.

Table A-1. Ethernet NIU Specifications

PARAMETER

SPECIFICATION

Remarks

Power

Voltage

–48VDC, or 110 to 240VAC (50–60 Hz)

Operating Voltage

+5 VDC

Backplane connector

Input Current

0.25 A maximum 

Normal operation

Fuse Size

1.0 Amps

–48 VDC

Environmental

Operating Conditions

+23

°

F to +122

°

F (–5

°

C to +50

°

C) 5% to 90% RH

Storage Conditions

-40

°

F to +185

°

F (-40

°

C to +85

°

C) 10% to 95% RH

No Condensation

Mechanical

Dimensions D x W x H

1.55 in. 

× 

4.25 in. 

×

 9.09 in. 

(3.94 cm 

×

 10.8 cm 

×

 23.1 cm)

Weight

1.8 lb. (0.81 kg.)

Electrical

Network Interface

RJ-45, SFP

Network Data Rates

Configurable to 10Mbps, 100Mbps or 1000Mbps

Customer Interface

RJ-45, SFP [Small Form-factor Pluggable (SFP) 
Transceiver Multi-Source Agreement (MSA)]

Customer Data Rates

Configurable to 10Mbps, 100Mbps or 1000Mbps

Copper Media 
Requirements

10Mbps UTP Category 3, 4, 5 or better

Two twisted pair

100Mbps UTP Category 5 or better

Two twisted pair

1000Mbps UTP Category 5e or better

Four twisted pair

Distance

328 feet (100 meters)

Copper

Optical Media Requirements 850 to 1550 nm

Single Mode or Multi-Mode 
fiber

Distance

The maximum distance that any optical link can 
support is dependent upon attenuation and dispersion 
at a particular wavelength, maximum bit rate, receiver 
sensitivity, splice and connector loss, etc. Refer to SFP 
specifications for operating parameters.

Optical

Summary of Contents for Network Unit

Page 1: ...Ethernet Network Interface Unit ENIU User Manual 20383 A1 ENI EGXXEGXX1B Document Number AIWN UM 7001 01 Product Catalog ENI EGXXEGXX1B CLEI IPUIAY5F...

Page 2: ...re used for identification purposes only and may be trademarks or regis tered trademarks of their respective companies Disclaimer of Liability Information contained in this document is company private...

Page 3: ...2 2 Power Connection 2 3 Cabling 2 4 RJ 45 Ethernet Cables 2 4 Optical Cables 2 5 DB 9 Communications Cable 2 6 Chapter 3 Command Line Interface CLI 3 1 Command Prompt 3 1 Set Up 3 1 Commands Overview...

Page 4: ...Table of Contents August 7 2006 iv AIWN UM 7001 01...

Page 5: ...iew 1 2 Figure 2 1 Inserting ENIU into Mounting Bracket 2 2 Figure 2 2 ENIU Rear View with RJ 45 Connector 2 3 Figure 2 3 Four Pin Power Plug Wiring Diagram 2 3 Figure 2 4 ENIU Front View with RJ 45 C...

Page 6: ...List of Figures August 7 2006 vi AIWN UM 7001 01...

Page 7: ...e 2 1 10 100 Mbps Ethernet RJ 45 Connector 2 5 Table 2 2 1000BaseT Ethernet RJ 45 Connector 2 5 Table 2 3 EIA 232 DCE Control Connector Female 9 Pin D Sub 2 6 Table 2 4 EIA 232 Serial Port Default Set...

Page 8: ...List of Tables August 7 2006 viii AIWN UM 7001 01...

Page 9: ...ns Provides physical specifications for the ENIU including power mechanical environmental and electrical requirements Appendix B Product Support Provides information on how to contact the ADC Technica...

Page 10: ...f necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact ADC as described in Appendix B Product Support on page B 1...

Page 11: ...blems remotely through use of the OAM Protocol Data Units PDU The ENIU provides the following capabilities One Ethernet Network Port One Ethernet Subscriber Port Full 802 3ah OAM functionality Enhance...

Page 12: ...w Table 1 1 ENIU LED Indicators and Controls SIGNAL COLOR STATUS STATUS GREEN ENIU Power OK and operating properly RED A service affecting fault exists within the ENIU OFF ENIU Power OFF LPBK GREEN Fl...

Page 13: ...page 2 2 See Appendix A Specifications for fuse size 4 Verify that the STATUS LED is lit DANGER Infrared radiation is invisible and can seriously damage the retina of the eye Do not look into the opt...

Page 14: ...ccordance with all local and national electrical codes The ENIU should be connected directly to a grounding electrode conductor or to a bonding jumper from a grounded electric box 6 Connect the power...

Page 15: ...n see Appendix A Specifications for fuse size Plug the power plug into the power connector located on the back of the ENIU Step Action 1 Using AWG 16 1 25mm solid copper wire connect one end of the gr...

Page 16: ...shown in Table 2 1 on page 2 5 Table 2 2 on page 2 5 and Figure 2 5 Figure 2 5 RJ 45 Connector Wiring a Use Cat5e or better cable strip back cable jacket to expose the four wire pairs the metallic she...

Page 17: ...rate used Refer to SFP specifications for operating parameters Pin Signal Name Function Pin Signal Name Function 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 4 Not used 5 Not used 6 RX Rece...

Page 18: ...PC Pinout information is shown in Table 2 3 and Figure 2 6 Table 2 3 EIA 232 DCE Control Connector Female 9 Pin D Sub Figure 2 6 9 Pin D Sub Connector EIA 232 Communication Port Defaults Host termina...

Page 19: ...rial communications cable The user must provide network cables Cat5e or better Ethernet cables for electrical interfaces or optical cables appropriate to the SFP for optical connections A PC with Hype...

Page 20: ...nt except user and software maintenance Secure SECURE users may do and see whatever they want including user and software maintenance Users have 3 attributes username user privilege RO RW SECURE and p...

Page 21: ...rovides a mechanism to limit the amount of bandwidth that the SUBSCRIBER can use Command RW SECURE privilege SET TRANSMIT RECEIVE DATA RATE FULL value TRANSMIT or RECEIVE is optional and is specified...

Page 22: ...eriod has elapsed and return the ENIU to normal state of passing data Timeout values are specified in minutes ranging from 10 to 240 minutes or 0 to disable the timeout The ENIU implements OAM and ext...

Page 23: ...N System Name Purpose Configure the system name Command RW SECURE privilege SET SYSTEM NAME name CLEAR SYSTEM NAME Status Commands all privileges GET CONFIGURATION OAM Configuration The ENIU supports...

Page 24: ...figure OAM Extensions Purpose Configure the individual OAM extensions that allow for OAM operation over a VLAN and for use with EXFO test equipment Command RW SECURE privilege SET DISCOVERY MODE ON OF...

Page 25: ...er interface can optionally be specified to target a specific interface when not specified both interfaces are tar geted interface must be either NETWORK or SUBSCRIBER type is one of CRC FRAME FRAME P...

Page 26: ...Purpose View and reset 15 minute and daily performance totals Command RW SECURE privilege CLEAR PERFORMANCE STATUS Status Commands all privileges GET DAY PERFORMANCE STATUS The 15 minute totals are d...

Page 27: ...rform an LED test for the front panel LEDs Command RW SECURE privilege SET LED TEST Reset Purpose Restart the firmware in the ENIU Command RW SECURE privilege RESET Software Maintenance Purpose Load n...

Page 28: ...Chapter 3 Provisioning August 7 2006 3 10 AIWN UM 7001 01...

Page 29: ...terface RJ 45 SFP Network Data Rates Configurable to 10Mbps 100Mbps or 1000Mbps Customer Interface RJ 45 SFP Small Form factor Pluggable SFP Transceiver Multi Source Agreement MSA Customer Data Rates...

Page 30: ...Appendix A Specifications August 7 2006 A 2 AIWN UM 7001 01...

Page 31: ...nitoring upstream or downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements and Systems Operation ADC Technical Assistance Center 800 366 3891 Email wsd support adc com Tec...

Page 32: ...Appendix B Product Support August 7 2006 B 2 AIWN UM 7001 01...

Page 33: ...Ethernet Network Interface Unit F FCC Federal Communications Commission G GND Ground L LEC Local Exchange Carrier LED Light Emitting Diode M MON Monitor O OAM Operations Administration and Maintenanc...

Page 34: ...Glossary August 7 2006 GL 2 AIWN UM 7001 01...

Page 35: ...ble protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 36: ...communications Inc PO Box 1101 Minneapolis MN 55440 1101 USA For Technical Assistance Tel 800 366 3891 Ethernet Network Interface Unit ENIU User Manual Document Number Product Catalog ENI EGXXEGXX1B A...

Reviews: