AIWN-UM-7001-01
3-1
3
Chapter
C
OMMAND
-L
INE
I
NTERFACE
(CLI)
This section lists the commands used to operate the ENIU. After the initial installation of an ENIU, most testing and
local operations are conducted with the Command Line Interface through a VT-100 compatible terminal. This
terminal is connected to the front panel of the ENIU, and provides a standard EIA-232C interface.
C
OMMAND
P
ROMPT
The CLI provides a prompt with a character indicating the user’s privilege level.
Table 3-1. CLI Command Prompts
S
ET
-U
P
The ENIU requires minimal set-up to provide OAM PDU reception, reporting, and remote loop-back functionality.
The ENIU is shipped with a power supply connector, and a serial communications cable. The user must provide
network cables (Cat5e or better Ethernet cables for electrical interfaces or optical cables appropriate to the SFP for
optical connections). A PC with HyperTerminal or equivalent is required with an available COM port for status
monitoring. Follow these steps to connect the unit:
Note:
Command keywords are not case-sensitive.
Effective privilege
Prompt
RO
command $
RW
command %
SECURE
command #
Step
Action
1
Connect Ethernet and/or optical cables to the desired equipment.
2
Connect the serial communications cable to the Command port of the ENIU and to any COM port on the
local PC.
3
Launch HyperTerminal and configure it for 115200 bits per second, 8 data bits, 0 parity bits, 1 stop bit,
and no flow control.
4
Connect the power supply to the appropriate connector on the ENIU.
5
Verify that the terminal displays a configuration screen.
Summary of Contents for Network Unit
Page 4: ...Table of Contents August 7 2006 iv AIWN UM 7001 01...
Page 6: ...List of Figures August 7 2006 vi AIWN UM 7001 01...
Page 8: ...List of Tables August 7 2006 viii AIWN UM 7001 01...
Page 28: ...Chapter 3 Provisioning August 7 2006 3 10 AIWN UM 7001 01...
Page 30: ...Appendix A Specifications August 7 2006 A 2 AIWN UM 7001 01...
Page 32: ...Appendix B Product Support August 7 2006 B 2 AIWN UM 7001 01...