![ADC HIGAIN HXU-359 Manual Download Page 57](http://html1.mh-extra.com/html/adc/higain-hxu-359/higain-hxu-359_manual_2847878057.webp)
150-359-100-01, Revision 01
Testing
HXU-359 List 1
October 27, 2000
47
STS-1 Loopbacks
To set a loopback for the STS-1 interface:
1
Choose Config, then Transport.
2
Set Primary State to OOS-M by pressing
. Then press
and use the
key to select the Loopback.
3
Press
to view the loopback options (NONE, TERM or
FCLT), then press
to activate a loopback.
To deactivate the TERM or FCLT loopback for the transport:
4
Set Primary State to IS.
5
Press the
key to select the Loopback and press
to select
NONE. Press
.
Figure 30.
System Loopbacks
SPACEBAR
ENTER
TAB
SPACEBAR
ENTER
TAB
SPACEBAR
ENTER