c) Remove the optical cartridge (1) by hinging it down, disconnecting the lamp connector and lifting the cartridge out of
the hinge.
Insert the cable through the housing (3), and install the light without optical cartridge on the conduit, without
tightening the bracing clamp (5).
d) Clamp the cable into the stress reliever (6).
e) Cut the cable in the light fitting to the right length, maintaining sufficient slack to easily connect the cable to the
connector.
Connect the cable to the connector.
f) Adjust the position of the light unit, see §
Orientation and elevation settings
g) Once the position of the light is correct, put the optical cartridge back in place.
h) Insert the lamp connector back in place.
i) Close the light fitting.
4.5.3 Illustration
The illustration below gives an overview of the procedure described above.
High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS)