Configuration Switch SW1 is used to set the operational configuration of the Radio Control Equipment. See
additional information.
Table 8: Radio Control Configuration Switch
POSITION
DESCRIPTION
ON
OFF
4
Debug Mode
Do Not Use
Debug Mode Off
3
Canada Mode J Operation
Canada Mode J
Standard Operation
2
Relay Channel A Operation
Cumulative Mode
Individual Mode
1
Relay Channel B Operation
Cumulative Mode
Individual Mode
A set of LEDs above each solid state relay shows that relay’s commanded status.
There are two fuses on the board, as shown below in
Table 9: Relay Board Fuse Layout
ITEM
PART
DESCRIPTION
FUNCTION
F1
47A0214
5A 5mm x 20mm SLO BLO
Ch A Switch Voltage Input
F2
47A0214
5A 5mm x 20mm SLO BLO
Ch B Switch Voltage Input
96A0390, Rev. K, 2019/02/01