2.5 Technical Specifications
2.5.1 AGLAS Specifications
Description
Remote
Master
Operating temperature
-40 °C to +65 °C
0 °C to +55 °C
Storage temperature
-55 °C to +85 °C
-40 °C to +75 °C
Operating humidity
Max. 100 %
Max. 95 % non condensing
Series circuit operating voltage
–
Max. 5000 V AC RMS
Min. / max. Power line current
1.8 up to 6.9 A RMS
1.8 up to 6.9 A RMS
Series circuit peak voltage
–
Max. 15 kV
Maximum switching power secondary side
of transformer
300 W (single Remote)
Ch A + Ch B < 300 W (dual)
-
Maximum circuit load (CCR power)
–
30 kVA
Power consumption
Max. 8 W at 6.6 A
Max. 15 W for power supply 115-230 V
Max. 65 W on primary circuit at 6.6 A
Enclosure protection level
IP 68 / NEMA 6 P
IP 20
LAN connection to upper control system
–
IEEE 802.3 100 BaseT / IEEE1588 PTP
Net voltage of power supply
–
115 - 230 V AC ±15 %, 50/60 Hz
MTBF
> 200.000 h
> 200.000 h
Indicative MTTR
< 30 min
< 60 min
Lightning protection
20 kA (8/20 micro sec.)
17 kA (8/20 micro sec.)
EMC (CE approved)
Compliant to the EN 61000-6-4 (EMC emission standard)
Compliant to the EN 61000-6-2 and 6-5 (EMC immunity standard)
Compliant to the 60950 (IT equipment standard)
Power Up Mode
On; Off; Flashing; Maintained (last commanded state)
Fail-Safe Mode
On; Off; Flashing, Maintained (last commanded state)
Number of controlled and monitored
lamps per unit
1 or 2
Up to 300 Remotes or 600 lights, if dual
Remotes are used
Number of I/O Remotes per circuit
–
Max. 16
Transmit Frequency
11 different frequency bands between 20 kHz and 200 kHz
Data transmission rate power line
Up to 8 kbps
Up to 8 kbps
Dimensions (W x H x D) / Weight
208 x 78 x 142 / 2,2 kg (single Remote)
/2,3 kg (dual)
435,8 x 177,5 x 421,5mm / 22,3 kg
Lamp failure reaction
Short is placed across isolation
transformer as soon as lamp filament
failure detected
–
Power Storage after Power-Off
Remote does not reset and remains in
operation, if circuit power loss < 1.5 sec.
Remote start up time is less than 1 sec.
–