4. Enter the Short Error Status decimal number from Intelligent Control.
5. Click
Bin
.
This converts the decimal value to the binary equivalent.
Each digit in the resulting binary equivalent is always a zero or a one. One indicates an error. Starting with zero, and
counting from the right you can use the position of each error to determine the meaning.
Example:
1. Start with 1665 as the Decimal Short Error Status number.
2. Convert it to binary. The binary number equivalent = 11010000001.
3. Determine the Short Error Status position.
Starting with zero on the right, log the position of each 1. In this case, the positions are 0, 7, 9, and 10.
4. Look up each position in the “Error status definitions” table on page 3.
In this case:
0 = Reserved
7 = Message error
9 = Temperature warning
10 = Fan error
Decimal Short Error Status number
1665
Binary number equivalent
1
1
0
1
0
0
0
0
0
0
1
Short Error Status position
10
9
8
7
6
5
4
3
2
1
0