4-6
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
To use the One-Touch Annunciation, press and hold the
Alarm
Reset
button. The drive activity LEDs are turned off and the drive
status LEDs illuminate in unique combinations to designate certain
enclosure conditions.
describes the drive status LEDs and
their meanings when using the One-Touch Annunciation.
Table 4-3 Drive Status LEDs Used for One-Touch Annunciation
Drive Slot
Description
Status LED On
Status LED Off
1
Bus configuration
Dual-bus
Single-bus
2
Hot interface type
SCSI Host
Fibre Host
3
N/A
4
Switch 1 SCSI IDs
Enabled
Disabled
5
Baud rate, switch 6
19,200 baud
9,600 baud
6
N/A
7
Switch 2 SCSI IDs
Enabled
Disabled
8
Delay restart, switch 7
Disabled
Enabled
9
Controller 1
Green: good
Not installed
Amber: failed
10
Switch 3 RAID addressing
Enabled for
RAID
Disabled for
JBOD
11
Remote start switch 8
Disabled
Enabled
12
Controller 2
Green: good
Not installed
Amber: failed
DuraStor IUG - Online.book Page 6 Friday, July 19, 2002 3:06 PM