C-14
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
The switch settings assign specific SCSI IDs to the drive slots, as
shown in
, and reserve IDs 6 and 7 for
the RAID Controller(s), and IDs 8 or 15 for the SAF-TE
processors.
3
Reinstall the SAF-TE disk I/O card in each enclosure. See
for instructions.
4
Remove the SAF-TE disk I/O card installed in the first daisy-
chain enclosure. See
for
instructions.
The first daisy-chain enclosure is configured to dual-bus mode.
It provides the drive channel expansion from the primary
enclosures’ disk I/O channels. Set the switches as shown in
.
Figure C-16 Switch Setting – Dual-Bus Daisy-Chain Enclosure
5
(First Daisy-chain Enclosure
) Change the jumper settings on the
SAF-TE disk I/O card JP7 and JP8 as described.
Locate and add the two jumpers (JP7 and JP8). See
for help locating the jumpers. Add a jumper
(installed on both pins) to JP8 for Channel 1 and JP7 for
Channel 2.
This ensures that the automatic termination feature functions
properly.
6
Reinstall the SAF-TE disk I/O card into the daisy-chain
enclosure. See
instructions.
Switch Settings
ID 9
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 11
ID 11
ID 13
ID 13
ID 10
ID 10
ID 12
ID 12
ID 14
ID 14
UP (1)
DOWN (0)
Dr ive IDs of the Dr ive S lots ( Dr ive C hannel Side)
SAF-TE ID = 15/15
RAID Controllers = 6 & 7
Du a l-B us Mo d e
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8
DuraStor IUG - Online.book Page 14 Friday, July 19, 2002 3:06 PM