6-16
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
Disk Errors
If a disk detects an error, it reports the error and records it in the
event log. The following is an example of a disk-detected error.
Figure 6-1 Disk Detected Error Example
Using the information in the Sense Key and ASC tables, you can
see that this is a medium error, unrecovered read error –
recommended reassignment.
Table 6-1 Sense Key Descriptions
Sense Key
Description
Sense Key
Description
0h
No sense
9h
Vendor-specific
1h
Recovered error
Ah
Copy aborted
2h
Not ready
Bh
Aborted command
3h
Medium error
Bh
Aborted command
4h
Hardware error
Ch
Obsolete
5h
Illegal request
Dh
Volumes overflow
6h
Unit attention
Eh
Miscompare
7h
Data protect
Fh
Reserved
8h
Blank check
Table 6-2 ASC and ASCQ Descriptions
ASC
ASCQ
Description
0C
02
Write error, auto-reallocation failed.
0C
03
Write error, recommend reassignment.
11
00
Unrecovered read error.
11
01
Read retries exhausted.
11
02
Error too long to correct.
11
03
Multiple read errors.
11
04
Unrecovered read error, auto-reallocation failed.
11
0B
Unrecovered read error, recommend reassignment.
11
0C
Unrecovered rear error, recommend rewrite data.
47
00
SCSI parity error.
48
00
Initiator-detected error message received.
DISK DETECTED ERR
Disk Channel
SCSI ID
Sense Code Qualifier
Sense Code
Sense Key
2:05
03,11,0B
DuraStor IUG - Online.book Page 16 Friday, July 19, 2002 3:06 PM