C-18
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
switch setting is the same for both of these daisy-chained
enclosures. Set the switches as shown in
Figure C-20 Switch Setting – Single-Bus Daisy-Chain Enclosure
8
(Second & third daisy-chain enclosure)
Change the jumper settings
on the SAF-TE Disk I/O card JP7 and JP8 as described.
Locate and add the two jumpers (JP7 and JP8). See
for help locating the jumpers. Add a jumper
(installed on both pins) to JP8 for Channel 1 and JP7 for
Channel 2. This will ensure that the automatic termination
feature functions properly.
9
Reinstall the SAF-TE Disk I/O cards in each enclosure. See
for detailed instructions.
10
(Second & third daisy-chain enclosure)
Install the Single-Bus
Module in the Controller 1 slot in both of these enclosures. For
details, see
Installing the Single Bus Module and Cover Plate
11
Connect the SCSI data cables as shown in
Switch Settings
ID 1
ID 9
Slot 1
Slot 7
Slot 4
Slot 10
Slot 2
Slot 8
Slot 5
Slot 11
Slot 3
Slot 9
Slot 6
Slot 12
ID 3
ID 11
ID 5
ID 13
ID 2
ID 10
ID 4
ID 12
ID 0
ID 14
UP (1)
DOWN (0)
Dr ive IDs of the Dr ive S lots ( Dr ive C hannel Side)
SAF-TE ID = 15
RAID Controllers = 6 & 7
Single-Bus Mode
A
0
1
A
1
2
R
D
3
S
0
4
S
1
5
B
D
6
D
L
7
R
M
8
DuraStor IUG - Online.book Page 18 Friday, July 19, 2002 3:06 PM