© Adam Equipment Company 2018
13
12.0 PARAMETER SETTING
This section allows the user to access the parameters for customising the scale. The
parameters are split into 2 groups-
1. Check weighing Parameters
2. Scale Parameters
In the following sections use the
[Limit]
key to scroll through the options, the
[Tare]
key to
accept the option and the
[Zero]
key to return to weighing. Wherever numeric values are
required to be entered, use the
[Limit]
and
[Unit]
keys to increment the flashing digits as
explained in section 4.1.
13.1 CHECK WEIGHING PARAMETERS
To enter this section press and hold the
[Limit]
key for 4 seconds. You will be asked for the
password if the current check-weighing password is anything other than “0000”. See the
parameter “
F4 PS
” in this section. Enter the correct password using the numeric entry method
as mentioned in section 4.1. If the password is “0000” it will go directly to “
F1 LLK
”.
Parameter
Description
Options
Default setting
F1 LLt
Limit Lock will prevent a normal user
from changing the check weighing
limits. To change the limits, this
parameter must be disabled by
setting it to off or the user must enter
the password.
oFF
All
Pst
(preset)
oFF
F2 LEd
Setting the LED
on
oFF
PSt
on
F3 bEP
This parameter sets the Beeper to
off or on. If set to on, the beeper can
further be set to sound when the
weighing result is within or outside
the check-weighing limits.
bP oFF
- Off
bP inL
- Within
limits
bP otL
- Outside
limits (>20d)
bP inL
F4 PS
This parameter allows setting of a
new Check weighing password,
If the old parameter is “0000” enter
the new password twice when “
P1 _
_ _
“ & “
P2 _ _ _ _
” are displayed.
When complete, it will display
“
donE
”. If the old parameter is other
than “0000”, enter the old one when
“
P _ _ _ _
” is displayed and then
enter the new password twice when
asked. When complete, it will
display “
donE
”.
To be entered
manually.
0000