background image

©Adam Equipment Co. 2019 

16 

7.1 

SCALE

 

PARAMETERS

Pressing  the

  [Func/C]

  key  and  holding  for  2  seconds

 

during  normal

operation

 

allows the user to access the parameters.

Scroll through the list of functions using the 

 and 

 directional keys. Press

[Tare/

to enter a parameter.

Press 

[

0

/Esc] 

to exit the scale parameter section and return to normal

weighing.

This group of parameters is used to control the operation of the scale. 

Parameter 

Description 

Options 

Default 
setting 

Time 

Set Time. 

Enter the time manually. 

00:00:00 

Date 

Set date format and settings. 
Format  for  date  can  be 
changed  when  the  display 
shows  mmddyy,  ddmmyy  or 
yymmdd  by  pressing  the

 

[Pcs/ ]

  key,  then  enter  the 

date. 

Enter  the  date  format  and 
then  the  numeric  value 
manually. 

mm:dd:yy 

bL 

Backlight  set  to  always  on, 
always  off  or  automatic  on 
whenever a weight is placed or 
a key is pressed 

oFF  
on  
AUTO 

AUTO 

Power 

Disable  or  set  time  increment 
to turn off scale 





10 
15 
Off 

Key bp 

Key beeper settings 

On 
Off 

On 

Chk bp 

Checkweighing 

beeper 

settings 

In 
Out 
Off 

In 

Unit 

Enable  or  disable  weighing 
units,  will  not  allow  to  disable 
all units, at least one has to be 
enabled. Parts counting can be 
enabled/disabled 

Kg 
Grams  
lb 
oz 
lb:oz 
N (Newtons) 
PCS 

Kg 

Auto-Z 

Auto zero settings 

0.5 

1.5 

2.5 

0.5 

Filter 

Filter setting to slow, normal or 
fast 

Slower 
Slowest 
Faster 

Faster 

Summary of Contents for AGF 600aM

Page 1: ...Adam Equipment AGF Floor Scale Software rev V 1 00 above Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 2: ...Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Page 3: ...HECK WEIGHING 9 6 7 1 Relay outputs and checkweighing 9 6 8 ACCUMULATED TOTAL 11 6 10 ANIMAL Dynamic WEIGHING 12 6 10 1 Animal weighing procedure 13 6 11 ANIMAL 2 DYNAMIC 2 WEIGHING 13 6 11 1 Animal 2...

Page 4: ...ighing semi automatic tare and an accumulation facility that allows individual weights or counts to be stored and the total recalled The scales have a bi directional RS 232 interface for communicating...

Page 5: ...ity 175lb 80kg 350lb 160kg 660lb 300kg 1320lb 600kg Readability 0 005lb 2g 0 01lb 5g 0 02lb 10g 0 05lb 20g Resolution 0 005lb 2g 0 01lb 5g 0 02lb 10g 0 05lb 20g Repeatability 0 005lb 2g 0 01lb 5g 0 02...

Page 6: ...n the backlight is used Interface RS 232 bi directional Interface Display 6 digits 40mm digit height LCD digital display with backlight Balance Housing Indicator IP 67 rated Stainless Steel Scale Grad...

Page 7: ...es Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not place near vibrating machinery Avoid air movement such as from fans or openi...

Page 8: ...n for scrolling Also used for incrementing the active digit when setting a value for Parameters Disp Mode Selects the weighing unit to be displayed from those which are enabled See parameter rS1 in se...

Page 9: ...ery 6 0 OPERATION 6 1 ZEROING THE DISPLAY You can press the 0 Esc key at any time to set the zero point This will usually be necessary when the platform is empty You can only zero off a weight up to a...

Page 10: ...Again only the weight that is added after taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is...

Page 11: ...known number of samples in the container if used The number should match the options for parts counting i e 10 20 50 100 or 200 pieces Press the Func Set key to select the weighing mode Using the dire...

Page 12: ...o move to the next digit Press Tare to confirm Once confirmed Lo will appear on the display followed by a value on the display with a flashing digit To set the low limit follow the same process as bef...

Page 13: ...n The beeper will be on when the weight is less than the High Limit Above the High Limit the beeper will be off CHK bP Out When set to bP OtL the indicator alarm will turn on below the high limit with...

Page 14: ...memory for 2 seconds before returning to weighing The RS 232 interface will output to a printer or PC Remove the weight allowing the scale to return to zero and put a second weight on When this value...

Page 15: ...eight of 100 on platform Press the Disp Mode key Display will show 100 The weight entered must be greater than 50 scale divisions Press the Func Set key to select a new weighing mode NOTE The display...

Page 16: ...termined The time it takes for the stable value will depend upon the setting of the filter parameter in the first step When a stable reading is found the display will show this value and the display w...

Page 17: ...kets alternatively a long press on the Tare key will retain the container or blanket value as NET Place the animals or sample to be weighed on the platform Press Tare key to start to the measurement T...

Page 18: ...e top right corner of the display Once the weight has stabilised the weight value will remain on the display until either more weight is added onto the weighing pan or the weighing mode is changed If...

Page 19: ...be changed when the display shows mmddyy ddmmyy or yymmdd by pressing the Pcs key then enter the date Enter the date format and then the numeric value manually mm dd yy bL Backlight set to always on...

Page 20: ...directional keys Press Tare to enter the rs 1 or rs 2 parameters when appearing on the display Rs 1 will provide access to Print PC and Cmd settings Rs 2 includes PC and Cmd only Press Tare to confirm...

Page 21: ...r 7 Lfcr 8 Lfcr 9 Lfcr 10 Lfcr 1 Lfcr Scale will perform the following depending on the Accumulation and Print Settings ACCUMULATION SETTINGS PRINT SETTINGS AC on AC Off AUto Accumulate and print auto...

Page 22: ...The battery should be charged when only the battery outline is on Once the bars have been turned off the scale will still operate for a short time after which it will automatically switch off to prot...

Page 23: ...eived Data 3 Pin TXD Transmitted Data As viewed from the back of the indicator The scale can be set to print text in English French German Spanish Italian or Portuguese See the RS 232 parameters secti...

Page 24: ...lf Peak Holt Wt 1 500 Kg cr lf cr lf cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Hold Wt 1 000 Kg cr lf cr lf cr lf...

Page 25: ...00 cr lf Unit wt 1 0234g Pieces 1000 PCS cr lf cr lf cr lf cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 500 Kg cr lf Ref Wt 10...

Page 26: ...Piezas Pezzi Pe as High Limit set by user High Limit Lim Sup rieure Obergrenze Lim Superior Lim Superiore Lim Superior Low Limit set by user Low Limit Lim Inf rieure Untergrenze Lim Inferior Lim Infe...

Page 27: ...enter the password use the directional buttons or to scroll through numbers 1 9 Use the directional key to move to the next digit Entering the correct password 1000 will bring you to the user setup me...

Page 28: ...em persists contact your dealer or Adam Equipment for assistance Err 6 A D out of range The values from the A D converter are outside the normal range Remove the weight from the scale if overloaded Ma...

Page 29: ...ady A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be ava...

Page 30: ...aulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable batter...

Page 31: ...rcial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio c...

Page 32: ...bed as follows Analytical and Precision Laboratory Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check we...

Reviews: