©Adam Equipment Co. 2019
10
LOW LIMIT SET
HIGH LIMIT is set to
zero
The display will be amber when
the weight is less than the Low
Limit. Above the Low Limit the
display backlight will be green,
CHK bP = In
The beeper will be off when the
weight is less than the Low Limit.
Above the Low Limit the beeper will
be on
CHK bP = Out
The beeper will be on sound when
the weight is below the Low Limit
HIGH LIMIT SET
LOW LIMIT is set to
zero
The display will show a red
backlight until High limit is
reached, then green backlight
above the High limit. Beeper will
turn on after High limit.
CHK bP = In
The beeper will be on when the
weight is less than the High Limit.
Above the High Limit the beeper will
be off.
CHK bP = Out
When set to bP OtL the indicator
alarm will turn on below the high
limit with red backlight.
The beeper will be off when the
weight is below the High Limit, on
when it is above the High limit.
BOTH LIMITS SET.
LOW
IS
SET
GREATER
THAN
HIGH
This condition is not allowed.
NOTE:
Weight must be more than 20 scale divisions for check weighing to operate. Below 20
scale divisions the LED’s will not light and the beeper will not be on.
The Check-weighing function can be set up during Weighing or Parts Counting by entering
values as Low or/and High Limits keyed in by the user. The limits are displayed in
kg (or
Lb)
or
pcs
respectively.
Checkweighing during Parts Counting