PROBLEMS
POSSIBILI CAUSES
SOLUTIONS
The motor overheats
1. The used liquid has a very high viscosity
2. Obstructed filters
3. Suction pipe either dirty or obstructed
4. Faulty motor
5. Blocked pump impeller
1. Must transfer for small periods of time, certainly
much less than 30 minutes of the max cycle.
2. Clean the filters
3. Clean suction pipe
4. Contact the seller
5. Check and clean impeller and impeller chamber
The motor does not start
1. No current
2. Defective interruption
3. Defective motor
4. Defective technical protections
5. Defective or loosened electrical components
1. Check its electrical network
2. Contact the dealer
3. -
4. -
5. Check the electrical contacts
Loss of liquids
1 Ruined OR gaskets
2. Dirty shaft seal ring
3. Ruined shaft seal ring
4. Not compatible liquids
5. Loss of tightening
1. Check the state of all the OR gaskets
2. Clean the seal ring and its seat
3. Substitute the seal ring
4. Ask your supplier for the composition of the
liquid
5. Tighten all screws
39