SYSTEM SETUP

17. Zone Setup

When the system is first powered 

up, the Tablet will automatically 
initialise and detect installed 
components.

Once the initialisation process is 

complete, the Zone setup screen 
is displayed.  If the Zone Dampers 
have been installed correctly, all 
Zones should be shown.  If a 
known Zone is not detected, a 
simple 'Recheck' may resolve the 
issue.  If this does not resolve the 
issue, it will be necessary to 
investigate Zone Damper 
components, faulty cables or plug 
connections.

If there is a problem with a 

detected Zone Damper it will be 
indicated with an   .  This is 
usually due to a jammed Zone 
Damper and it will be necessary to 
investigate the Zone Damper in 
the roof space.  Once resolved, 
tap ‘Recheck’ to continue.

‘X’

SYSTEM SET UP

INSTALLATION MANUAL

24

25

Once satisfied with the detected 

Zones, each Zone can be 
individually configured.

Each room can be named by 

selecting one of the default names 
provided, or by entering a custom 
name.  Room colour can also be 
changed to suit user preference.

 
  

Summary of Contents for Platinum Elite

Page 1: ...INSTALLATION MANUAL ZONE CONTROL SYSTEM...

Page 2: ...2...

Page 3: ...Fujitsu WiringDiagram 14 CommissioningNotes 15 13 ACControl MitsubishiElectric WiringDiagram 16 CommissioningNotes 17 1 14 ACControl MitsubishiHeavy WiringDiagram 18 CommissioningNotes 19 15 ACContro...

Page 4: ...kind DO NOT place articles filled with water on or near this appliance DO NOT remove covers there are no serviceable part inside DO use only genuine Air Diffusion Agencies components Ensure all electr...

Page 5: ...Power Supply PEPS Platinum Elite Gateway to suit AC brand PEGSN NASA PEGM PEGS NO NASA PEGMHI PEGD PEGP PEGF PEGT 2 3 4 core AC Link Cable PETCW PE3CW PE4CW for use with Platinum Elite Gateway Wireles...

Page 6: ...on and size of each Zone Damper on the record sheet in the back of this manual noting which if any are designated as Relief Zones It is recommended to use an off the shelf cable tester to check the Co...

Page 7: ...agrams After completing wiring and setting the DIP switches power up the system AC Unit Platinum Elite Gateway and Platinum Elite Zone Control System can be powered up at the same time but if powered...

Page 8: ...adiant heat inadvertently affecting the AC temperature sensor Avoid mounting in direct sunlight Avoid mounting in direct airflow of an AC vent The Mounting Plate is used as a template for marking the...

Page 9: ...ck of the Tablet then simply push Tablet onto the Mounting Plate and slide down so it clips into place Mounting Plate Mounting Screw Coms Cable Tablet MOUNTING THE TABLET 100mm exclusion zone to any o...

Page 10: ...TCW supplied with Platinum Elite Cable Kit Tablet Cat6 cable 24VDC Power Supply AC Indoor Unit PCB Platinum Elite Gateway PEGSN SW1 SW3 SW4 Gateway Address Setting Gateway No ON 1 Default SW3 ON ON ON...

Page 11: ...ture to compatible AC Units from either the temperature sensor in the Tablet or one of the connected Temperature Sensors Utilising this feature will potentially modify the control loop for the AC Unit...

Page 12: ...VDC Power Supply AC Indoor Unit PCB Platinum Elite Gateway PEGS SW1 SW3 SW4 SW1 Slave Master ON ON Gateway Master Slave Setting A B F3 F4 V1 V2 F3 F4 V1 V2 2 core cable PETCW supplied with Platinum El...

Page 13: ...before the Platinum Elite Zone Control System Follow the Platinum Elite onscreen prompts to complete the AC setup The Platinum Elite system is capable of providing an external reference temperature to...

Page 14: ...Indoor Unit PCB Platinum Elite Gateway PEGD SW1 SW3 SW4 SW1 Slave Master ON ON Gateway Master Slave Setting A B P1 P2 P1 P2 2 core cable PETCW supplied with Platinum Elite Cable Kit 2 core cable PETCW...

Page 15: ...ite system is capable of providing an external reference temperature to compatible AC Units from either the temperature sensor in the Tablet or one of the connected Temperature Sensors Utilising this...

Page 16: ...r Supply AC Indoor Unit PCB Platinum Elite Gateway PEGF SW1 SW3 SW4 SW1 Slave Master ON ON Gateway Master Slave Setting A B B W R 3 2 1 B W R 3 2 1 2 core cable PETCW supplied with Platinum Elite Cabl...

Page 17: ...o compatible AC Units from either the temperature sensor in the Tablet or one of the connected Temperature Sensors Utilising this feature will potentially modify the control loop for the AC Unit and a...

Page 18: ...Wiring Diagram Cable with plugs supplied with Gateway Tablet Cat6 cable 24VDC Power Supply AC Indoor Unit PCB Platinum Elite Gateway PEGM SW1 SW3 SW4 SW1 3 or 4 2 ON ON Fan Speed Setting A B CN105 2...

Page 19: ...apable of providing an external reference temperature to compatible AC Units from either the temperature sensor in the Tablet or one of the connected Temperature Sensors Utilising this feature will po...

Page 20: ...oor Unit PCB Platinum Elite Gateway PEGMHI SW1 SW3 SW4 SW1 Slave Master ON ON Gateway Master Slave Setting A B X Y X Y SW1 1 2 ON ON Fan Speed Setting 3 4 ON ON 2 core cable PETCW supplied with Platin...

Page 21: ...he AC return air sensor Follow the Platinum Elite onscreen prompts to complete the AC setup The Platinum Elite system is capable of providing an external reference temperature to compatible AC Units f...

Page 22: ...et Cat6 cable 24VDC Power Supply AC Indoor Unit PCB Platinum Elite Gateway PEGP SW1 SW3 SW4 A B R1 R2 R1 R2 2 core cable PETCW supplied with Platinum Elite Cable Kit 2 core cable PETCW supplied with P...

Page 23: ...he Platinum Elite system is capable of providing an external reference temperature to compatible AC Units from either the temperature sensor in the Tablet or one of the connected Temperature Sensors U...

Page 24: ...Gateway PEGT SW1 SW3 SW4 SW1 Slave Master ON ON Gateway Master Slave Setting A B A B A B SW1 Not Defined RAV ON ON Indoor Unit Setting VRF SMMS VRF SHRM ON ON 2 core cable PETCW supplied with Platinu...

Page 25: ...ensors Utilising this feature will potentially modify the control loop for the AC Unit and as such requires precise configuration of the AC Unit the Platinum Elite Gateway and the Platinum Elite Table...

Page 26: ...should be shown If a known Zone is not detected a simple Recheck may resolve the issue If this does not resolve the issue it will be necessary to investigate Zone Damper components faulty cables or pl...

Page 27: ...sfied with the detected Zones each Zone can be individually configured Each room can be named by selecting one of the default names provided or by entering a custom name Room colour can also be change...

Page 28: ...ture Sensor may be required In the event a Plug in Temperature Sensor is used this should automatically be indicated on the relevant Zone Setup screen Tap the sender button on the Wireless Temperature...

Page 29: ...for each Zone NOTE Setting the Duct Sizes is important to ensure the best performance of the system when Relief Zones are correctly designed and configured Disconnect can be used when it is required t...

Page 30: ...re must be a Zone where no Damper is fitted to allow for the minimum airflow requirement and prevent any damage to the air conditioning system Complete Setup When using a Platinum Elite Gateway the Zo...

Page 31: ...otes if using external reference sensors tap on AC icon to select an alternate Reference Temperature Sensor Depending on the installation configuration this could be the Tablet or one of the connected...

Page 32: ...completed minimize the Platinum Elite app and go to Settings find Wi Fi settings and available Wi Fi networks will appear Choose the desired network and type in the password to connect After successfu...

Page 33: ...SYSTEM SET UP 31 20 Software Update Once connected to Wi Fi the system may indicate an updated version of the software is available Follow the onscreen prompts to update...

Page 34: ...installed use the Settings icon to access the Devices tab and tap Add a device Use the app to scan the QR code and then name the device following the onscreen prompts NOTE If your camera is not worki...

Page 35: ...All user access to Software Version Support System information Zones diagnostic information and connected Devices are available from this screen This information may be useful in the event of a servi...

Page 36: ...es to Zone Setup can now be made To access AC Setup from the Settings screen tap the System icon then tap the box showing the AC name It will require the 4 digit installer code to access the AC Setup...

Page 37: ...ure for the AC system and is unable to be mounted in the optimum position to ensure the best performance of the system it may be necessary to set a temperature offset on the temperature registered by...

Page 38: ...nt of the AC system If the system has been setup to allow use of an external Temperature Reference Sensor this setting will normally be the Tablet This can be changed to any Zone linked to a Temperatu...

Page 39: ...uld appear in the list on the left and can then be setup using this screen NOTE The same process can be used to remove a Zone Any unplugged Zone or a Zone in fault when a Recheck is activated will be...

Page 40: ...he Gateway is added after the initial setup process on the Zone Setup screen it will be necessary to perform a Recheck to allow the Gateway to be detected NOTE Ensure no Zones or Temperature Sensors a...

Page 41: ...l reset the system then return to the Zone Setup screen presented during an initial set up NOTE It is possible to do a factory reset of the Tablet by using a small pin or paperclip to press the factor...

Page 42: ...SYSTEM SET UP INSTALLATION MANUAL 40...

Page 43: ...dent misuse abuse improper installation or operation lack of reasonable care vermin infestation unauthorised modifications loss of parts tampering or attempted repair by a person not authorised by Air...

Page 44: ...ified personnel Repairs carried out by unqualified personnel will void warranty For basic Troubleshooting information refer to the Troubleshooting table For additional information FAQ s and other help...

Page 45: ...at sensor battery Insufficient signal strength Faulty sensor Sensor unplugged Faulty sensor cable Replace sensor battery Try alternate sensor position Replace sensor Check plug connections Replace sen...

Page 46: ...24 INSTALLATION MANUAL Zone Room Zone Relief Sensor ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 INSTALLATION MANUAL 44 ZONE SETUP SHEET...

Page 47: ......

Page 48: ...ADAPEI0521 www platinumzoning com For the latest version of the Installation Manual scan the QR code...