4. INSTRUCTIONS FOR THE GAS FRYER INSTALLER
Connection of the fryer to the gas installation can only be carried out by a person with
appropriate qualifications. Parts that have been secured by the manufacturer may not be adjusted
by the installer.
4.1. Description of components
Gas installation
The fryer is equipped with a set of burners and a gas installation which includes:
- main gas burner with pilot burner,
- ignition electrode with piezo igniter,
- flame sensor (thermocouple),
- MNISIT 710 control valve with oil temperature sensor (thermostat),
- max limiter oil temperature (230 °C),
- fryer gas pipes together with the gas connector.
Fig. 3. Pilot burner
The pilot burner consists of an ignition electrode [3] on one side and a thermocouple [2] on the opposite
side (flame sensor that switches off the gas supply to the device in the event of its disappearance). On the
front side there is a connection nut [1]
The fryer can be connected to the B/P supply via a gas pressure reducer or natural gas E and will
therefore be equipped with a suitable (in accordance with the order) gas connection:
1) B/P - with a ø12 tip for B/P systems for a flexible hose,
2) natural gas E - with external thread G ½ for natural gas E (G20) (fig. 4).
A change of gas type may only be carried out by authorized persons. To change the type of gas, replace
the set of gas burners and adjust the pilot burner.
7